鄔鵬躍 張一秋 石洪成
(復(fù)旦大學(xué)附屬中山醫(yī)院核醫(yī)學(xué)科,上海 200032)
甲狀旁腺是位于甲狀腺兩側(cè)上下極后壁或在甲狀腺組織內(nèi)的橢圓形腺體,93.5%的人有4個腺體,部分人多至5~7個或少于4個[1]。其主要功能是分泌甲狀旁腺素(parathyroid hormone,PTH)以維持體內(nèi)鈣、磷的平衡和調(diào)節(jié)骨代謝。甲狀旁腺疾病是一組由PTH產(chǎn)生異?;蚰┥移鞴賹TH的反應(yīng)異常所致的以鈣、磷代謝紊亂為特征的常見內(nèi)分泌疾病,分為甲狀旁腺功能亢進(jìn)(hyperparathyroidism,HPT)和甲狀旁腺功能減低,臨床上以前者常見。HPT可分為原發(fā)性甲狀旁腺功能亢進(jìn)癥(primary hyperparathyroidism,PHT)、繼發(fā)性甲狀旁腺功能亢進(jìn)癥(secondary hyperparathyroidism,SHPT)和三發(fā)性甲狀旁腺功能亢進(jìn)癥(tertiary hyperparathyroidism,THPT)。PHT 中 約85%由單發(fā)甲狀旁腺腺瘤(parathyroid adenoma,PTA)所致,10%~15%由甲狀旁腺增生(parathyroid hyperplasia,PTHP)、多發(fā)PTA或甲狀旁腺腺癌引起[2]。目前,診斷甲狀旁腺病變的常用方法包括頸部超聲及放射性核素檢查,本文就放射性核素檢查在PTA診斷中的應(yīng)用及其與其他影像診斷方法的對比作一綜述。
1.1 雙核素減影法顯像 在20世紀(jì)80年代初期,201TlCl/99mTc-高锝酸鹽(99mTcO4- )雙核素減影顯像法被成功地應(yīng)用于甲狀旁腺顯影。隨后發(fā)現(xiàn)甲狀旁腺對99mTc-甲氧基異丁基異腈(99mTc-MIBI)具有高攝取的物理特性,99mTc-MIBI/99mTcO4-、99mTc-MIBI/123I雙核素減影法顯像逐步應(yīng)用于臨床。雙核素減影法顯像的原理是:甲狀腺組織既可攝取99mTcO4-、123I,又可攝取201Tl或99mTc-MIBI,而甲狀旁腺組織僅能攝取201Tl或99mTc-MIBI,通過計算機(jī)減影處理獲得甲狀旁腺影像的相關(guān)信息;正常甲狀旁腺由于體積較小、質(zhì)量較輕、血流量和細(xì)胞活性相對較低,故而不顯影;而甲狀旁腺病變則表現(xiàn)為異常放射性分布。
1.299mTc-MIBI雙時相顯影法 1989年,Coakly等[3]將99mTc-MIBI應(yīng)用于甲狀旁腺雙時相顯像,該藥物可以與細(xì)胞內(nèi)線粒體相結(jié)合,功能亢進(jìn)的甲狀旁腺組織內(nèi)含豐富的線粒體,從而使病變組織顯像。此法原理是甲狀腺和甲狀旁腺組織均能攝取99mTc-MIBI,但正常甲狀腺和甲狀旁腺組織對99mTc-MIBI的洗脫速度較病變甲狀旁腺組織快,故通過兩個不同時間點(diǎn)的適時顯像并進(jìn)行對比觀察,即可鑒別診斷PTA和PTHP。正常甲狀旁腺不顯影,而 HPT、PTHP、PTA及甲狀旁腺癌則表現(xiàn)為局灶性異常放射性濃聚灶。與雙核素減影法顯像相比,99mTc-MIBI雙時相顯影法操作更加簡便,因99mTc所發(fā)射出的射線能量適度,不僅圖像質(zhì)量好,且更適合于進(jìn)行單光子發(fā)射計算機(jī)斷層顯像 (single-photon emission computed tomography,SPECT)和深部甲狀腺病灶的顯示,因此成為臨床上主要的檢查方法。
SPECT是通過探頭圍繞人體旋轉(zhuǎn)而采集人體內(nèi)發(fā)射的γ射線并經(jīng)計算機(jī)處理后獲得人體局部斷層圖像的技術(shù)[4]。與放射性核素平面顯像相比,SPECT圖像對較小的、放射性濃聚程度低的病灶更加敏感,提高了診斷PTA的靈敏度。Thomas等[5]對36例行99mTc-MIBI雙時相平面顯像與SPECT、并經(jīng)手術(shù)后病理證實(shí)的HPT患者進(jìn)行臨床研究,結(jié)果顯示,雙時相平面顯像診斷PTA的敏感性為54%,而SPECT診斷PTA的敏感性為79%。此外,SPECT在異位甲狀旁腺的定位、甲狀旁腺病變的良惡性鑒別和轉(zhuǎn)移性淋巴結(jié)的確定等方面亦具有較高的臨床價值。
SPECT/CT是通過一次檢查即可獲得局部組織的SPECT圖像、診斷CT圖像以及二者的融合圖像,可以提高對病灶的探測效率,提供準(zhǔn)確的定位信息[6]。Neumann等[7]對57例行99mTc-MIBI/123I雙核素減影法顯像,并經(jīng)手術(shù)病理證實(shí)HPT患者的研究顯示,SPECT和SPECT/CT診斷甲狀旁腺病變的靈敏度分別為71%和70%,但SPECT/CT的特異度(96%)顯著高于SPECT(48%)。由此可見,SPECT/CT不僅能夠顯示核素聚集灶的部位和大小,為外科手術(shù)術(shù)前提供精確的定位信息,還具有較高的敏感度和特異度[8]。
γ-探針是一款便攜式的放射檢測裝置,當(dāng)探頭區(qū)域放射性計數(shù)增高時,便以聲音或者實(shí)時放射性計數(shù)顯示的方式予以提示。γ-探針是根據(jù)甲狀腺組織及甲狀旁腺組織對放射性藥物的藥代動力學(xué)差異而設(shè)計的[9],主要適用于99mTc-MIBI顯像檢查陰性、但臨床高度懷疑PTA的患者,此法不僅可以有效減少術(shù)中尋找病灶的時間,而且可以提高切除甲狀旁腺病變組織的成功率[10]。
目前,診斷PTA往往首選實(shí)驗(yàn)室檢查,包括血鈣、血磷及PTH的測定等;之后繼以影像學(xué)檢查,包括頸部超聲檢查、CT、磁共振成像(magnetic resonance imaging,MRI)、放射性核素顯像等。此外,B超引導(dǎo)下針吸甲狀旁腺組織測定血漿全段甲狀旁腺素(intact parathyroid hormone,iPTH)及病理學(xué)檢查、選擇性靜脈PTH測定等檢測方法為PTA的診斷提供了更多選擇。各種檢查方法各有優(yōu)勢、相輔相成[11-14],各項檢查方法的特性見表1。
表1 PTA常用檢查方法比較
總之,甲狀旁腺放射性核素平面顯像,可以通過全身掃描進(jìn)行原位甲狀旁腺病變的診斷和異位甲狀旁腺的定位。在平面顯像的基礎(chǔ)上,進(jìn)行局部SPECT/CT融合顯像,能進(jìn)一步提高PTA的診斷率[15]。
[1]Chakraborty D,Mittal BR,Harisankar CN,et al.Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas[J].Indian J Nucl Med,2011,26(1):52-55.
[2]Udelsman R,Pasieka JL,Sturgeon C,et al.Surgery for asymptomatic primary hyperparathyroidism:proceedings of the third international workshop[J].J Clin Endocrinol Metab,2009,94(2):366-372.
[3]Coakley AJ,Kettle AG,Wells CP,et al.99Tcm sestamibi-a new agent for parathyroid imaging[J].Nucl Med Commun,1989,10(11):791-794.
[4]Oksuz MO,Dittmann H,Wicke C,et al.Accuracy of parathyroid imaging:a comparison of planar scintigraphy,SPECT,SPECT-CT,and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia[J].Diagn Interv Radiol,2011,17(4):297-307.
[5]Thomas DL,Bartel T,Menda Y,et al.Single photon emission computed tomography(SPECT)should be routinely performed for the detection of parathyroid abnormalities utilizing technetium-99m sestamibi parathyroid scintigraphy[J].Clin Nucl Med,2009,34(10):651-655.
[6]Lavely WC,Goetze S,F(xiàn)riedman KP,et al.Comparison of SPECT/CT,SPECT,and planar imaging with single-and dual-phase(99m)Tc-sestamibi parathyroid scintigraphy[J].J Nucl Med,2007,48(7):1084-1089.
[7]Neumann DR,Obuchowski NA,Difilippo FP.Preoperative123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism[J].J Nucl Med,2008,49(12):2012-2017.
[8]Nichols KJ,Tomas MB,Tronco GG,et al.Preoperative parathyroid scintigraphic lesion localization:accuracy of various types of readings[J].Radiology,2008,248(1):221-232.
[9]Ugur O,Bozkurt MF,Rubello D.Nuclear medicine techniques for radio-guided surgery of hyperparathyroidism[J].Minerva Endocrinol,2008,33(2):95-104.
[10]Rubello D,Gross MD,Mariani G,et al.Scintigraphic techniques in primary hyperparathyroidism:from pre-operative localisation to intra-operative imaging[J].Eur J Nucl Med Mol Imag,2007,34(6):926-933.
[11]Patel CN,Salahudeen HM,Lansdown M,et al.Clinical utility of ultrasound and99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism[J].Clin Radiol,2010,65(4):278-287.
[12]Kiblut NK,Cussac JF,Soudan B,et al.Fine needle aspiration and intraparathyroid intact parathyroid hormone measurement for reoperative parathyroid surgery[J].World J Surg,2004,28(11):1143-1147.
[13]Mariani G,Gulec SA,Rubello D,et al.Preoperative localization and radioguided parathyroid surgery[J].J Nucl Med,2003,44(9):1443-1458.
[14]Rubello D,Pelizzo MR,Boni G,et al.Radioguided surgery of primary hyperparathyroidism using the low-dose99mTc-sestamibi protocol:multiinstitutional experience from the Italian Study Group on Radioguided Surgery and Immunoscintigraphy(GISCRIS)[J].J Nucl Med,2005,46(2):220-226.
[15]Vaz A,Griffiths M.Parathyroid imaging and localization using SPECT/CT:initial results[J].J Nucl Med Technol,2011,39(3):195-200.