劉暢
摘 要
小電流接地系統(tǒng)中暫態(tài)信號(hào)豐富。提取有效的暫態(tài)信號(hào)進(jìn)行選線 將提升選線的準(zhǔn)確率。本文通過(guò)希爾伯特黃變黃對(duì)暫態(tài)信號(hào)進(jìn)行處理。通過(guò)提取各線路零序電流并進(jìn)行分解處理。對(duì)最高頻的固有模態(tài)函數(shù)進(jìn)行時(shí)頻分析,比較各線路故障時(shí)刻的極性,從而達(dá)到選線效果。
關(guān)鍵詞
暫態(tài)信號(hào);希爾伯特黃變換;零序電流
中圖分類號(hào): TM862 ? ? ? ? ? ? ? ? ? ? 文獻(xiàn)標(biāo)識(shí)碼: A
DOI:10.19694/j.cnki.issn2095-2457 . 2020 . 08 . 48
Abstract
Transient signals are abundant in low-current grounding systems. Extracting valid transient signals for line selection will improve the accuracy of line selection. In this paper, the transient signal is processed by Hilbert yellowing. The zero-sequence current of each line is extracted and decomposed. Time-frequency analysis is performed on the highest frequency natural mode function, and the polarity of each line fault moment is compared to achieve the effect of line selection
Key words
Transient signal; Hilbert yellow transform; zero sequence current
0 引言
小電流接地系統(tǒng)中故障電流較小,故障信息難以提取,是配電網(wǎng)故障選線的一個(gè)難題。零序電流中含有大量的暫態(tài)分量,HHT通過(guò)經(jīng)驗(yàn)?zāi)B(tài)分解EMD可以把信號(hào)分解為幾個(gè)固有模態(tài)函數(shù)IMF分量的和,并對(duì)IMF進(jìn)行Hilbert變換得到有物理意義的瞬時(shí)頻率。HHT是一種基于信號(hào)局部特征的方法,其優(yōu)點(diǎn)是可以自適應(yīng)地篩選出IMF分量,從而可以克服小波變換中選取小波基的困難。
1 單相接地故障的暫態(tài)零序電流特征分析
系統(tǒng)發(fā)生單相接地故障時(shí)其結(jié)構(gòu)如圖1所示。
發(fā)生單相接地故障時(shí),流過(guò)故障點(diǎn)的接地電流由暫態(tài)電容電流和暫態(tài)電感電流兩部分組成。因兩者在頻率上存在明顯不同,因此兩者在暫態(tài)過(guò)程中不能夠相互補(bǔ)償,單相接地故障時(shí)零序電流暫態(tài)過(guò)程等值電路圖如下。
4 結(jié)語(yǔ)
本文采用HHT變換對(duì)小電流接地系統(tǒng)進(jìn)行故障選線,對(duì)故障后各線路零序電流經(jīng)EMD分解,得到若干從高頻到低頻分量,對(duì)各條線路最高頻IMF分量進(jìn)行時(shí)頻分析,比較各線路故障時(shí)刻的極性從而可以正確選線。通過(guò)仿真算例驗(yàn)證了該分解方法的完備性,選線原理簡(jiǎn)單,可以達(dá)到選線效果。
參考文獻(xiàn)
[1]戴栩生,黃純,葉倩,等.基于暫態(tài)相關(guān)性分析的小電流接地故障選線方法[J].中國(guó)電力,2015,48(1):81-86.
[2]王磊,駱瑋,曹現(xiàn)峰.基于改進(jìn)EMD算法的小電流接地故障選線[J].電氣工程學(xué)報(bào),2015,10(8): 29-34,44.