王學(xué)亮
摘? 要:基于提高暖通安裝施工水平的目的,針對(duì)施工中需要注意的問(wèn)題,做了簡(jiǎn)單的論述,總結(jié)了施工質(zhì)控要點(diǎn),共享給相關(guān)人員參考。首先,分析了暖通安裝的質(zhì)控目標(biāo)。其次,結(jié)合實(shí)例分析了暖通安裝施工技術(shù)應(yīng)用要點(diǎn)。最后,根據(jù)暖通安裝作業(yè)實(shí)踐經(jīng)驗(yàn),總結(jié)了工程施工的質(zhì)控策略。
關(guān)鍵詞:暖通安裝;技術(shù)要點(diǎn);質(zhì)量管理
中圖分類(lèi)號(hào):TU83 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):2095-2945(2020)15-0128-02
Abstract: For the purpose of improving the construction level of HVAC installation, this paper makes a simple discussion on the problems needing attention in the construction, summarizes the key points of construction quality control, and shares them for reference to the relevant personnel. First of all, the quality control target of HVAC installation is analyzed. Secondly, combined with an example, the application points of HVAC installation construction technology are analyzed. Finally, according to the practical experience of HVAC installation, the quality control strategy of engineering construction is summarized.
Keywords: HVAC installation; technical points; quality management
基于人們的建筑使用需求多樣化背景,暖通系統(tǒng)被廣泛應(yīng)用。暖通系統(tǒng)指的是供熱供燃?xì)馔L(fēng)及空調(diào)工程,劃分為采暖系統(tǒng)、通風(fēng)系統(tǒng)和空氣調(diào)節(jié)系統(tǒng)。若想保證暖通工程質(zhì)量和價(jià)值的發(fā)揮,要做好安裝全過(guò)程的質(zhì)量把控,為使用者提供良好的溫濕度條件和空氣服務(wù)等,改善室內(nèi)環(huán)境。
1 暖通安裝的目標(biāo)
基于質(zhì)控的角度分析,暖通安裝管理要達(dá)到以下目標(biāo):(1)全過(guò)程。暖通工程施工涉及到的內(nèi)容較多,若想保證各個(gè)分系統(tǒng)的運(yùn)行效益,要做好全過(guò)程質(zhì)控,最大程度上減少質(zhì)量問(wèn)題的發(fā)生,確保暖通工程的建設(shè)質(zhì)量達(dá)標(biāo)。(2)全面化。暖通安裝質(zhì)量的影響因素較多,包括設(shè)計(jì)和材料以及施工等,要結(jié)合各個(gè)影響因素的特點(diǎn),采取全面化把控措施,確保暖通系統(tǒng)運(yùn)行的效率,實(shí)現(xiàn)暖通工程效益目標(biāo)[1]。
2 暖通安裝施工技術(shù)應(yīng)用要點(diǎn)的實(shí)例分析
2.1 案例概述
以某建筑為例,為4層框架結(jié)構(gòu),建筑面積大約為4500m2。建筑1層層高設(shè)計(jì)為4.5m,凈高要求3.2m;建筑2-4層客房層高設(shè)計(jì)為3.9m,凈高度為3.2m。建筑內(nèi)部衛(wèi)生間高度要求超過(guò)3.0m,走廊寬度設(shè)計(jì)為3.9m。此建筑暖通系統(tǒng)設(shè)計(jì)要求,客房tnx=22-24℃,Φnx=55-65%;tnd=22-25℃,Φnd=40-50%,噪聲要求不超過(guò)39分貝。建筑室內(nèi)人員活動(dòng)區(qū)域無(wú)吹風(fēng)感。其中,tnx指的是夏季室內(nèi)溫度;tnd指的是冬季室內(nèi)溫度;Φnx指的是夏季室內(nèi)相對(duì)濕度;Φnd指的是冬季室內(nèi)相對(duì)濕度。
2.2 空調(diào)主機(jī)方案
基于建設(shè)成本、自動(dòng)化運(yùn)維管理成本等,綜合對(duì)比分析,最終選擇了VRV變頻中央空調(diào)系統(tǒng),此建筑工程設(shè)計(jì)總負(fù)荷為550kW。設(shè)計(jì)的VRV空調(diào)系統(tǒng),選擇的是環(huán)保R401A制冷劑,同時(shí)實(shí)現(xiàn)室外主機(jī)由室內(nèi)控制的自由開(kāi)閉控制形式,可以自行調(diào)節(jié)空調(diào)??照{(diào)主機(jī)采用的是變頻控制系統(tǒng),有助于節(jié)能效益的實(shí)現(xiàn)。經(jīng)過(guò)綜合分析,最終選擇19組MDV空調(diào)主機(jī)。
2.3 空調(diào)末端方案
室內(nèi)空調(diào)末端采用的是風(fēng)機(jī)盤(pán)管+新風(fēng)方案,具體內(nèi)容如下:(1)新風(fēng)設(shè)計(jì)。建筑內(nèi)部的客房,新風(fēng)主要是由配置在走廊兩端的新風(fēng)機(jī)提供,新風(fēng)機(jī)送風(fēng)段布置了10kW陶瓷電加熱器管段,風(fēng)量大小按照規(guī)定確定。結(jié)合氣候以及使用環(huán)境,新風(fēng)機(jī)常年運(yùn)行,夏秋季節(jié)電加熱器不運(yùn)行。為了保證室內(nèi)空氣的質(zhì)量,配置了光催化空氣凈化器。(2)空調(diào)形式。基于凈高要求和使用需求,將風(fēng)機(jī)盤(pán)管布置在建筑走廊吊頂內(nèi)部,利用風(fēng)管輸送新風(fēng),為室內(nèi)提供空調(diào)風(fēng)。使用的風(fēng)機(jī)盤(pán)管,為大容量設(shè)備。設(shè)備的參數(shù)為,制冷/熱量14/12.5kW;電輔熱參數(shù)為2kW;風(fēng)量每小時(shí)1800m3;為了達(dá)到噪音要求,對(duì)送回風(fēng)管進(jìn)行消音處理,確保風(fēng)管和保溫效果,同時(shí)解決噪聲問(wèn)題。(3)風(fēng)管的布置和安裝。送風(fēng)管穿越客房門(mén)廊;回風(fēng)管設(shè)計(jì)穿過(guò)衛(wèi)生間上空,保證風(fēng)管均貼梁底,提高空間利用率,降低吹風(fēng)感覺(jué)。(4)末端控制方式。采取一臺(tái)風(fēng)機(jī)盤(pán)管配置1套雙控電路空調(diào)控制器,滿(mǎn)足雙向控制需求。
2.4 施工解決的問(wèn)題
從此暖通安裝工程施工實(shí)踐來(lái)說(shuō),主要解決了以下問(wèn)題:(1)噪聲超標(biāo)問(wèn)題。完成樣板房空調(diào)系統(tǒng)的安裝作業(yè)
后,組織試運(yùn)行,進(jìn)行運(yùn)行效果檢測(cè),發(fā)現(xiàn)客房出風(fēng)口位置噪聲超過(guò)40分貝,沒(méi)有達(dá)到施工標(biāo)準(zhǔn),組織施工調(diào)整。通過(guò)分析噪聲超標(biāo)原因,使用雙面保溫鍍鋅鐵皮消聲型復(fù)合風(fēng)管。施工中,對(duì)風(fēng)管內(nèi)部,采取粘貼6mm厚度的單面開(kāi)孔橡塑保溫板的方案處理;在風(fēng)管內(nèi)部,采取粘貼厚度為13mm的閉孔橡塑保溫板材的方案處理。同時(shí)為了補(bǔ)償風(fēng)管截面面積,對(duì)于送風(fēng)管尺寸大小進(jìn)行調(diào)整,優(yōu)化為1020×220mm;對(duì)回風(fēng)管尺寸大小進(jìn)行調(diào)整,優(yōu)化為1250×220mm。除此之外,在回風(fēng)管上配置消聲器,實(shí)現(xiàn)對(duì)噪聲的有效降低。
(2)空間利用問(wèn)題。從安裝現(xiàn)場(chǎng)的情況來(lái)說(shuō),衛(wèi)生間的設(shè)備器具比較多,占用的吊頂凈空很大,同時(shí)工程對(duì)凈高度有要求?;诖?,要處理風(fēng)管和衛(wèi)生間實(shí)施空間分配問(wèn)題。對(duì)于空調(diào)風(fēng)管,按照靠近門(mén)對(duì)面的內(nèi)墻安裝方案施工,制作為幾字形,為電器以及排氣扇風(fēng)管預(yù)留充足的空間。對(duì)于上層客房的坐便器和臺(tái)式洗臉盆等,按照先做貼定水平管,再制作存水彎,按照一字排開(kāi)的形式作業(yè),布置在靠近衛(wèi)生間門(mén)位置的一面墻。除此之外,在吊頂上制作檢修口,為后續(xù)運(yùn)維管理提供保障。對(duì)于各類(lèi)電氣設(shè)備和產(chǎn)品等,選擇小型產(chǎn)品[2]。
3 暖通安裝施工質(zhì)控策略的總結(jié)
3.1 合理設(shè)計(jì),準(zhǔn)確定位
暖通安裝施工質(zhì)量水平的提高,要做到合理設(shè)計(jì),精準(zhǔn)定位,保障設(shè)計(jì)的合理性以及系統(tǒng)性,提出科學(xué)可行的暖通安裝施工方案。從行業(yè)前沿分析,很多暖通安裝工程設(shè)計(jì),引入了BIM技術(shù),通過(guò)構(gòu)建建筑三維模型,進(jìn)行各專(zhuān)業(yè)的協(xié)同設(shè)計(jì)[3]。借助軟件的施工碰撞功能和三維可視化功能等,對(duì)管道線(xiàn)路設(shè)計(jì)進(jìn)行檢查,排查存在的碰撞和交叉問(wèn)題,采取優(yōu)化措施,減少施工問(wèn)題的出現(xiàn)。為了保障設(shè)計(jì)意圖精準(zhǔn)轉(zhuǎn)換,實(shí)踐中嚴(yán)格落實(shí)技術(shù)交底制度,使得作業(yè)人員能夠明確暖通安裝施工的要點(diǎn),為作業(yè)的質(zhì)量把關(guān)。對(duì)設(shè)備定位以及預(yù)埋情況等,進(jìn)行全面核對(duì),看是否能夠達(dá)到設(shè)計(jì)圖的要求,實(shí)現(xiàn)對(duì)施工問(wèn)題的事前控制。
3.2 采用三維交底技術(shù)
暖通安裝施工問(wèn)題的出現(xiàn),很多同施工人員對(duì)設(shè)計(jì)內(nèi)容把握不準(zhǔn)確有著緊密的關(guān)系?;诖耍氍F(xiàn)代化技術(shù),利用三維交底技術(shù),輔助施工前的技術(shù)交底工作,通過(guò)動(dòng)態(tài)模擬或者三維動(dòng)態(tài)模擬等方式,使得安裝作業(yè)人員能夠掌握技術(shù)要點(diǎn),做好嚴(yán)格把控,減少施工問(wèn)題的出現(xiàn)。施工作業(yè)人員要加強(qiáng)和技術(shù)人員的溝通,對(duì)存在的不明確問(wèn)題及時(shí)明晰,避免因?yàn)榧夹g(shù)操作不規(guī)范,影響暖通安裝施工的質(zhì)量,降低工程的效益水平[4]。
3.3 做好材料的質(zhì)量把控
暖通安裝施工作業(yè)中,對(duì)于質(zhì)量的把控,要注重材料質(zhì)量管控。一般來(lái)說(shuō),暖通工程中會(huì)使用到很多原材料和作業(yè)設(shè)備,包括管道和儀表以及空調(diào)機(jī)組等,材料的來(lái)源較多,并且產(chǎn)品的類(lèi)型差異,增加了材料質(zhì)控的難度?;诒U吓ò惭b施工作業(yè)效益的目的,圍繞材料采購(gòu)和進(jìn)場(chǎng)以及使用全過(guò)程,嚴(yán)格落實(shí)質(zhì)量檢測(cè),實(shí)現(xiàn)對(duì)材料質(zhì)量隱患的有效防范和應(yīng)對(duì),避免因?yàn)椴牧腺|(zhì)量不達(dá)標(biāo),影響暖通安裝的質(zhì)量與效益。對(duì)工程采用的新材料和新設(shè)備等,結(jié)合使用標(biāo)準(zhǔn)和規(guī)范,采用適宜的檢測(cè)手段,做好嚴(yán)格把關(guān),確保暖通安裝施工質(zhì)量達(dá)標(biāo)。對(duì)于大宗材料,比如管材與管件等,嚴(yán)格按照出廠(chǎng)質(zhì)量要求進(jìn)行檢查,確保所有材料均達(dá)到工程要求[5]。
3.4 做好暖通設(shè)備的安裝把控
暖通安裝施工作業(yè)中,主要包括新風(fēng)機(jī)和空調(diào)機(jī)組以及水管等的安裝,涉及到的內(nèi)容較多,要做好嚴(yán)格把控。在進(jìn)行新風(fēng)機(jī)與空調(diào)機(jī)的安裝作業(yè),要按照施工的要求和標(biāo)準(zhǔn),配置彈簧減震器。對(duì)于風(fēng)機(jī)和風(fēng)管,使用軟管做好連接;對(duì)于新風(fēng)機(jī)和水管,選擇軟接頭。水管安裝作業(yè)的開(kāi)展,必須要嚴(yán)格按照國(guó)家現(xiàn)行的規(guī)范,吊架應(yīng)該固定在梁上面。對(duì)于風(fēng)管的制作安裝,遵循現(xiàn)行的規(guī)范和標(biāo)準(zhǔn),做好嚴(yán)格控制,選擇風(fēng)機(jī)進(jìn)出口位置布置消聲器;選擇風(fēng)管相應(yīng)的位置,配置消聲器?;谫|(zhì)量的把控,圍繞工程材料與設(shè)備等,做好嚴(yán)格的控制,全面把控安裝作業(yè)環(huán)節(jié)的質(zhì)量,確保整個(gè)暖通安裝工程的質(zhì)量達(dá)標(biāo),實(shí)現(xiàn)施工作業(yè)的效益目標(biāo)[6]。針對(duì)工程施工作業(yè)常見(jiàn)的問(wèn)題,比如噪聲問(wèn)題和空間利用問(wèn)題等,結(jié)合暖通安裝施工的實(shí)際情況,提出可行的處理方案,高效率解決問(wèn)題,保障暖通安裝施工作業(yè)達(dá)到標(biāo)準(zhǔn),促使項(xiàng)目效益目標(biāo)實(shí)現(xiàn)。組織施工管理人員,做好施工全過(guò)程的質(zhì)量檢查,及時(shí)發(fā)現(xiàn)暖通安裝施工問(wèn)題,采取整改措施,保障暖通安裝施工的質(zhì)量和效益,實(shí)現(xiàn)工程建設(shè)的效益目標(biāo)。
3.5 做好工程驗(yàn)收
暖通安裝施工作業(yè)的開(kāi)展,要嚴(yán)格按照設(shè)計(jì)的施工方案和流程,做好全過(guò)程把控,確保工程施工的質(zhì)量達(dá)標(biāo)。施工全過(guò)程,發(fā)揮質(zhì)檢員的作用,做好施工質(zhì)量檢查;發(fā)揮監(jiān)理人員的力量,做好暖通安裝施工監(jiān)督管理。當(dāng)完成全部的安裝作業(yè)后,組織質(zhì)檢員和技術(shù)人員以及監(jiān)理人員等,進(jìn)行整體驗(yàn)收檢查,對(duì)存在的問(wèn)題,提出解決措施,把關(guān)暖通安裝施工質(zhì)量[7]。
4 結(jié)束語(yǔ)
綜上所述,暖通安裝施工作業(yè)的開(kāi)展,要做好全面的把控。文中結(jié)合實(shí)例,針對(duì)暖通安裝施工常見(jiàn)的問(wèn)題,分析了問(wèn)題優(yōu)化策略,同時(shí)提出了質(zhì)控策略。通過(guò)采取全過(guò)程質(zhì)量把控措施的方式,最大程度上減少質(zhì)量問(wèn)題的發(fā)生,進(jìn)而保障暖通安裝的質(zhì)量。
參考文獻(xiàn):
[1]湯瀅.機(jī)電安裝工程暖通空調(diào)新技術(shù)及發(fā)展趨勢(shì)探索[J].建材與裝飾,2019(32):230-231.
[2]陳龍庭.機(jī)電安裝工程暖通空調(diào)新技術(shù)及發(fā)展趨勢(shì)探索[J].地產(chǎn),2019(20):19.
[3]全進(jìn)學(xué).建筑安裝工程中暖通及給排水安裝常見(jiàn)問(wèn)題分析[J].綠色環(huán)保建材,2019(09):211-212.
[4]楊榮升.關(guān)于機(jī)電安裝工程中暖通空調(diào)的安裝探討[J].綠色環(huán)保建材,2019(07):211+213.
[5]周志華.現(xiàn)代暖通空調(diào)設(shè)備安裝的施工問(wèn)題與解決方案[J].居舍,2019(20):197+193.
[6]李勇.建筑安裝工程中暖通空調(diào)“綠色節(jié)能”運(yùn)行策略的構(gòu)建[J].科技風(fēng),2019(12):104.
[7]潘振新.機(jī)電安裝工程中暖通空調(diào)安裝施工工藝研究[J].住宅與房地產(chǎn),2019(12):275.