中圖分類(lèi)號(hào):TV743;X322 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1008-9500(2025)07-0174-03
DOI: 10.3969/j.issn.1008-9500.2025.07.051
Environmental Protection Measures and Implementation Effect of Pumped Storage Power Stations
WANGHejun',LUYingl,WEIYuchen
l.PingduBranchfQingdaoEcolgicalEnviroentureau;2QingdaoHengnngBiotechnologyCo,d.Qingdao6ina
Abstract:As an important peak shaving power source,pumped storage power stations play an irreplaceable role in the power system.Taking a pumped storage power station as an example,the environmental protection measures are analyzed,especiallymicrodiferentialblasting technologyandwetoperation technology,andthentheimplementation efct is evaluated.Research hasshownthat with theimplementationof environmentalprotection measures,theecological environmentof pumped storagepowerstations is efectivelyprotected,and waterresourcesarereasonablyutilized.
Keywords:pumped storagepowerstation;environmental protection;microdiferentialblasting technology;wetoperation technology
在電站建設(shè)過(guò)程中,如何實(shí)現(xiàn)經(jīng)濟(jì)效益與生態(tài)效益的平衡成為業(yè)界關(guān)注的焦點(diǎn)[。近年來(lái),我國(guó)在抽水蓄能電站環(huán)境保護(hù)方面進(jìn)行積極探索,取得顯著成效,為全球水電開(kāi)發(fā)提供有益借鑒。某抽水蓄能電站與最近城市郊區(qū)的距離是 31km ,與城市用電負(fù)荷中心毗鄰。研究區(qū)屬于高山、丘陵地帶,地面高程介于 250~1200m 。這里有自然保護(hù)區(qū),也有風(fēng)景名勝區(qū),為了避免污染環(huán)境,抽水蓄能電站與這些敏感區(qū)域保持較遠(yuǎn)的距離,同時(shí)采取相應(yīng)環(huán)境保護(hù)措施。
1抽水蓄能電站環(huán)境保護(hù)措施
電站選址時(shí),通過(guò)地理信息系統(tǒng)進(jìn)行多方案比選,選擇生態(tài)環(huán)境影響最小的站址。抽水蓄能電站建
設(shè)中,通過(guò)優(yōu)化選址,成功避開(kāi)浙江天目山國(guó)家級(jí)自然保護(hù)區(qū),最大限度地減少對(duì)珍稀動(dòng)植物的影響。施工過(guò)程中,本電站采取先進(jìn)的環(huán)保技術(shù)措施。
1.1微差爆破技術(shù)
工程施工中,爆破作業(yè)應(yīng)用微差爆破技術(shù),減少振動(dòng),降低噪聲污染。在抽水蓄能電站地下廠房開(kāi)挖施工中,采用毫秒級(jí)延時(shí)爆破,將總裝藥量分解為多個(gè)小藥量爆破單元,顯著降低爆破振動(dòng)對(duì)圍巖的損傷。具體操作中,要先明確保護(hù)區(qū)域充許的振動(dòng)速度,以此為依據(jù),確定安全允許藥量。通常而言,延時(shí)爆破裝藥量最大值不能超過(guò) Qmax 。爆破振動(dòng)安全允許標(biāo)準(zhǔn)如表1所示。
根據(jù)式(1)計(jì)算振動(dòng)安全距離,按照式(2)確定單響安全藥量,將其控制在 0.3kg/m3 以?xún)?nèi)。確定延時(shí)間隔時(shí),相鄰2個(gè)炮孔爆破時(shí)間超過(guò) 20ms ,但是控制在 30ms 以?xún)?nèi)。本工程采用光面爆破技術(shù),控制削減后的爆壓不會(huì)促使孔壁大幅度壓縮而導(dǎo)致破壞,將切向拉應(yīng)力充分利用起來(lái),促使炮孔四周出現(xiàn)徑向裂紋。為緩解振動(dòng),要設(shè)置減震溝,根據(jù)振動(dòng)安全距離公式,確定減震溝的具體位置,如圖1所示。減震溝寬度通常為 2~3m ,減震溝外側(cè)使用分層爆破法。分層爆破過(guò)程中,每層爆破之前都要挖掘深度1m 左右的減震溝。爆破過(guò)程要持續(xù)開(kāi)展跟蹤監(jiān)測(cè),從實(shí)際需求出發(fā)修正爆破參數(shù)。
表1爆破振動(dòng)安全允許標(biāo)準(zhǔn)
式中: R 為振動(dòng)安全允許距離, m ; 為延時(shí)爆破時(shí)使用的最大一段藥量, kg ; V 為安全允許速度, cm/s : K 為與爆破點(diǎn)、保護(hù)對(duì)象有關(guān)的地形、地質(zhì)條件系數(shù);
為爆破使用藥量, kg ; α 為衰減指數(shù)。
圖1減震溝具體位置
微差爆破技術(shù)的應(yīng)用大幅提高施工效率。通過(guò)優(yōu)化爆破參數(shù),單循環(huán)進(jìn)尺可提高 20%~30% ,同時(shí)減少超欠挖現(xiàn)象,降低混凝土回填量。在抽水蓄能電站建設(shè)中,采用微差爆破技術(shù)后,地下廠房開(kāi)挖工期縮短 15% ,節(jié)約成本約800萬(wàn)元。質(zhì)量控制方面,微差爆破技術(shù)通過(guò)精確的爆破設(shè)計(jì),確保開(kāi)挖輪廓的平整度。監(jiān)測(cè)數(shù)據(jù)顯示,開(kāi)挖面不平整度控制在 15cm 以?xún)?nèi),為后續(xù)支護(hù)施工創(chuàng)造良好條件。
1.2 濕法作業(yè)技術(shù)
1.2.1 控制揚(yáng)塵污染
濕法土石方開(kāi)挖技術(shù)的應(yīng)用中,水霧降塵能夠減少施工現(xiàn)場(chǎng)的揚(yáng)塵量。開(kāi)挖施工作業(yè)面布置高壓噴霧系統(tǒng),促使施工區(qū)域細(xì)顆粒物濃度降低幅度超過(guò)80% ,施工現(xiàn)場(chǎng)環(huán)境顯著改善。由于本工程周?chē)凶匀簧鷳B(tài)保護(hù)區(qū),控制指數(shù)要求非常高,該技術(shù)應(yīng)用效果良好,污染指數(shù)明顯降低。
1.2.2 控制邊坡穩(wěn)定
邊坡穩(wěn)定性控制方面,濕法開(kāi)挖通過(guò)調(diào)節(jié)水壓和流量,實(shí)現(xiàn)對(duì)巖體的溫和剝離。與傳統(tǒng)干法開(kāi)挖相比,邊坡失穩(wěn)風(fēng)險(xiǎn)降低 40% ,減少邊坡防護(hù)工程量。工程應(yīng)用表明,采用濕法開(kāi)挖后,邊坡防護(hù)成本節(jié)約 25% 。
1.2.3 施工效率高
濕法開(kāi)挖雖然增加水系統(tǒng)投入,但通過(guò)優(yōu)化水壓參數(shù),實(shí)際開(kāi)挖效率可至少達(dá)到干法開(kāi)挖的 90% 。這種開(kāi)挖技術(shù)的施工效率非常高,與傳統(tǒng)干法開(kāi)挖標(biāo)準(zhǔn)接近。同時(shí),這種開(kāi)挖技術(shù)的應(yīng)用能創(chuàng)造良好的環(huán)境效益。
1.2.4合理利用廢水循環(huán)系統(tǒng)
建立完善的廢水處理系統(tǒng),采用“沉淀-過(guò)濾-消毒”工藝,處理后的水質(zhì)達(dá)到回用標(biāo)準(zhǔn),可用于降塵、混凝土養(yǎng)護(hù)等用途。環(huán)境保護(hù)方面,廢水循環(huán)利用有效減少施工廢水排放,保護(hù)周邊水環(huán)境。監(jiān)測(cè)數(shù)據(jù)顯示,采用該技術(shù)后,施工區(qū)域下游水質(zhì)保持在地表水Ⅲ類(lèi)標(biāo)準(zhǔn)以上。經(jīng)濟(jì)效益分析表明,雖然廢水處理系統(tǒng)需要一次性投入,但通過(guò)水資源節(jié)約和排污費(fèi)減免,投資回收期一般在2~3年[2]。
1.2.5構(gòu)建全過(guò)程環(huán)境監(jiān)測(cè)系統(tǒng)
該企業(yè)通過(guò)構(gòu)建全過(guò)程環(huán)境監(jiān)測(cè)體系,施工期和隱匿性期都可以對(duì)水質(zhì)、大氣、噪聲、生態(tài)等指標(biāo)進(jìn)行實(shí)時(shí)監(jiān)測(cè)。通過(guò)安裝在線(xiàn)監(jiān)測(cè)設(shè)備,建立環(huán)境監(jiān)測(cè)數(shù)據(jù)中心,實(shí)現(xiàn)環(huán)境數(shù)據(jù)的實(shí)時(shí)采集、傳輸和分析,為環(huán)境保護(hù)決策提供科學(xué)依據(jù)。環(huán)境監(jiān)測(cè)數(shù)據(jù)的實(shí)時(shí)采集與分析為施工管理提供科學(xué)依據(jù)。當(dāng)監(jiān)測(cè)數(shù)據(jù)出現(xiàn)異常時(shí),系統(tǒng)會(huì)自動(dòng)預(yù)警,指導(dǎo)施工單位及時(shí)調(diào)整施工方案,最大限度降低環(huán)境影響。數(shù)據(jù)采集模塊結(jié)構(gòu)如圖2所示。
圖2數(shù)據(jù)采集模塊結(jié)構(gòu)
環(huán)境監(jiān)測(cè)系統(tǒng)安裝的數(shù)據(jù)集中器安裝有環(huán)境檢測(cè)裝置、逆變器和其他子采集設(shè)備。檢測(cè)數(shù)據(jù)實(shí)時(shí)采集通過(guò)運(yùn)行上位機(jī)就可以實(shí)現(xiàn)?,F(xiàn)代環(huán)境監(jiān)測(cè)已進(jìn)入智能化時(shí)代。抽水蓄能電站環(huán)境監(jiān)測(cè)應(yīng)用物聯(lián)網(wǎng)技術(shù)實(shí)時(shí)監(jiān)控,電站內(nèi)的各種數(shù)據(jù)都能夠?qū)崟r(shí)采集,獲得所有的關(guān)鍵參數(shù),如水壓、水位、電流以及電壓等,從而了解泵站的運(yùn)行狀態(tài),實(shí)現(xiàn)監(jiān)測(cè)設(shè)備的互聯(lián)互通,構(gòu)建立體化監(jiān)測(cè)網(wǎng)絡(luò),實(shí)時(shí)監(jiān)控獲得的數(shù)據(jù)都能夠同步展示,有異常情況,能夠及時(shí)處理。此外,環(huán)境監(jiān)測(cè)系統(tǒng)采用了報(bào)警機(jī)制,以聲、光、電等信號(hào)形式提醒操作人員處理。
本抽水蓄能電站建設(shè)中,應(yīng)用智能監(jiān)測(cè)系統(tǒng)成功預(yù)警潛在的水質(zhì)污染風(fēng)險(xiǎn),通過(guò)及時(shí)采取防控措施,避免環(huán)境污染事故的發(fā)生。該企業(yè)還將環(huán)境監(jiān)測(cè)數(shù)據(jù)詳細(xì)記錄,不斷積累,從中總結(jié)規(guī)律,推進(jìn)抽水蓄能電站綠色化發(fā)展。通過(guò)對(duì)監(jiān)測(cè)數(shù)據(jù)的分析和評(píng)估,可基于所獲得的結(jié)果優(yōu)化施工工藝,減少環(huán)境擾動(dòng)。此外,該抽水蓄能電站建設(shè)過(guò)程中,基于環(huán)境監(jiān)測(cè)數(shù)據(jù)改進(jìn)爆破工藝,使施工噪聲降低 20% ,粉塵排放減少 30% 。
2環(huán)境保護(hù)措施的實(shí)施效果
2.1生態(tài)環(huán)境得到有效保護(hù)
該抽水蓄能電站通過(guò)采取嚴(yán)格的環(huán)保措施,電站建設(shè)區(qū)域的植被覆蓋率保持在較高水平,野生動(dòng)物棲息地得到有效保護(hù)。該抽水蓄能電站通過(guò)實(shí)施生態(tài)修復(fù)工程,建設(shè)區(qū)域的植被覆蓋率較建設(shè)前提高 15% ,野生動(dòng)物種群數(shù)量保持穩(wěn)定。企業(yè)還研發(fā)和應(yīng)用新型環(huán)保技術(shù),工程建設(shè)中不斷提高環(huán)境保護(hù)水平。比如,該抽水蓄能電站采用新型生態(tài)友好型建筑材料,減少施工過(guò)程的環(huán)境污染,工程成本降低。
2.2水資源得到合理利用
企業(yè)不斷優(yōu)化水庫(kù)調(diào)度方案,確保下游生態(tài)基流穩(wěn)定,維持河流生態(tài)系統(tǒng)健康。抽水蓄能電站通過(guò)建立生態(tài)流量泄放設(shè)施,確保下游河道不斷流,維護(hù)河流生態(tài)系統(tǒng)良好[3]。監(jiān)測(cè)數(shù)據(jù)顯示,電站周邊空氣質(zhì)量、水質(zhì)指標(biāo)均達(dá)到或優(yōu)于國(guó)家標(biāo)準(zhǔn)。該抽水蓄能電站采取嚴(yán)格的揚(yáng)塵控制措施,施工期間細(xì)顆粒物濃度始終控制在 35μg/m3 以下,遠(yuǎn)低于國(guó)家標(biāo)準(zhǔn)限值。
3結(jié)論
抽水蓄能電站的環(huán)境保護(hù)工作是一項(xiàng)系統(tǒng)工程,需要技術(shù)創(chuàng)新、管理創(chuàng)新和理念創(chuàng)新,持續(xù)改進(jìn)環(huán)保措施,優(yōu)化環(huán)境管理。隨著全過(guò)程環(huán)境監(jiān)測(cè)體系的建立,抽水蓄能電站的環(huán)境保護(hù)工作取得顯著成效,實(shí)現(xiàn)環(huán)境保護(hù)與工程建設(shè)的有機(jī)統(tǒng)一,為實(shí)現(xiàn)能源發(fā)展與生態(tài)保護(hù)的雙贏目標(biāo)做出更大貢獻(xiàn)。
參考文獻(xiàn)
1 馬蕭蕭,吳強(qiáng),王亮春,等.抽水蓄能電站建設(shè)期環(huán)境與生態(tài)問(wèn)題及治理保護(hù)措施[J].水利水電快報(bào),2024(8):89-95.
2 陳柏言,劉黃誠(chéng),袁姬,等.抽水蓄能電站生態(tài)環(huán)境影響與環(huán)境影響評(píng)價(jià)要點(diǎn)研究[J].水力發(fā)電,2024(7):8-12.
3 劉艷領(lǐng),張文棟,程巖,等.抽水蓄能電站建設(shè)及運(yùn)營(yíng)對(duì)地下水環(huán)境影響研究:以陜西大莊里抽水蓄能電站為例[J].西北水電,2024(3):26-34.