        Natural ventilation and cooling system in Hong Kong

        2019-10-21 07:44:50LIUjiayong劉家永
        魅力中國(guó) 2019年18期
        關(guān)鍵詞:劉家

        LIUjiayong(劉家永)

        (CHINA CONSTRUCTION SECOND ENGRG BUREAU LTD.SHANGHAI BRANCH,ShagHai 2000135)

        In Hong Kong energy consumption of air conditioning system has a large proportion of the total energy consumption.According to the statistical data of electricity end-uses by EMSD, the energy consumption occupies 20% of the total electricity consumption.Here is a picture showing the percentage of different kinds of electricity uses.So if we can make full use of natural ventilation and cooling system to replace of mechanical cooling system, we can save lots of energy.The temperature of Hong Kong is always high, so the objective of air conditioning system is lowering the indoor temperature.So we can emphasis on the cooling system.

        Picture 1 electricity end-uses[1]

        Here I want to use an example to explain the advanced technology of natural ventilation and cooling system.Hong Kong Science and Technology Park is an excellent project in reducing energy consumption and applying natural ventilation and cooling system, particularly the Phase 3 of Science Park.

        Science Park Phase 3

        Every building incorporates the latest green technologies and sustainable building design, with a focus on cost-effective energy-saving measures, making it easy for businesses there to adopt green practices.“The new development has already gained recognition in the industry, winning the Grand Award in Green Building Award ("GBA")2014 - New Buildings Category - Completed Buildings.”[2]Showcasing the latest green construction technologies and sustainable building designs - such as the application and installation of natural ventilation, energy-efficient systems and renewable energy such as photovoltaic - every detail plays its part in the development’s vision of being a green role model for Hong Kong.Within the project, at least one of the buildings will be targeting the Leadership in Energy and Environmental Design (LEED) Platinum standard, a world recognized green rating system and presently the highest level of certification available.All buildings in the project are targeted to meet the strict Hong Kong Building Environmental Assessment Method (HKBEAM) Plus Platinum standard.

        I will introduce the design of natural ventilation and cooling system in Science Park in six aspects: mixed ventilation, Optimization of building towards, Ventilation atrium, Optimizing window-wall ration to 40%, and double-low-E glazing, Energy efficient envelopes and Green roof.

        Mixed ventilation system

        Hybrid ventilation system that combines three operating modes, you can adjust the mode according to a variety of outdoor conditions,including natural ventilation, natural cooling and air-conditioning mode (Cold water storage system).

        In summer, the hybrid ventilation system forms chimney effect between the walls, let the hot air rises and leave the building.This way the air gap as a buffer to reduce the energy consumption of air conditioning

        The Mixed Mode strategy brings together allthe advantages of a natural ventilationsystem combined with those of mechanicalcomfort cooling (air conditioning) to providethe best of both systems: Low energy use.Low running costs.Accurate temperature control.Improved comfort.

        Optimization of building towards

        Building orientation is north and south, reducing low-angle sunlight from east or west facades penetration, which can reduce energy consumption for air-conditioning system.And this design is also benefit for natural ventilation.According to the statistical data of wind rose researched by Hong Kong Observatory, Annual wind roses for Tai Po are showed in Picture

        Picture 2 Annual wind roses for Tai Po[3]

        Ventilation atrium

        Atrium not only allows sunlight to penetrate to come, but also to achieve natural cross ventilation.By providing a flow path through the building, they can also aid the adoption of a natural ventilation strategy for the surrounding rooms.In winter, high level vents or windows in the atrium are used to bring fresh cold air into the building as well to exhaust the hot polluted air.The air mixes naturally in the atrium owing to the convective flow patterns which develop in the space.In summer the building is ventilated using up flow displacement ventilation.Air enters through exterior windows in each room before flowing into the atrium.The air rises within the atrium and exits through the high level windows or vents at the top of the space.The large difference in height between the low level entry of fresh air and the exit of warm air through the atrium creates a large buoyancy effect which draws air through the building.

        Optimizing window-wall ration to 40%, and double-low-E glazing

        Double opening window units with high and low apertures have been used to ventilate warm air through the top vent.The design also allows cooler fresh air to enter the buildings through the lower vent.

        Energy efficient envelopes

        Energy efficient envelopes for the buildings include: the insulated west fa?ade, insulated green roof, optimized window areas,the highly insulated spandrel area.

        When all operable shutters and windows closed, hot air will leave the building facades reflectionOperable glass blinds are installed in the northwest and southwest sides of the external walls that receive the most solar position.Additional layer of additions to the building facades, and the gap can be manufactured blinds insulating glass curtain wall to form an effective buffer to reduce the absorption of solar energy, further reducing the energy consumption of office range.

        Green roof

        Green roof can reduce thermal absorption from the roof and cooling the indoor temperature.An unexpected delight awaits first-timevisitors to Green 18.Arriving on the roof,you are met by luscious of shrubs and trees,making it a place to stay a while and relax.It is perfect for rejuvenating lunch hours.Green roof can serve as buffer for storm water by absorbing rainwater (Green Roof) -reduce environmental loading, extend life span of roof - economic impact,reduce heat island effect - resources use and environmental loadings,serve as acoustic barrier (vertical Greenery) - indoor environmentalquality, extend functional open space (green roof) -social impact, aesthetically attractive - social impact.

        Conclusion

        With all this technologies, science park has achieved natural ventilation and energy saving.But we can also find that in HK, energy consumption of air-conditioning system is the main aspect of the whole energy consumption.We should pay more attention on the scientific and technologicalinvention and make full use of resources:

        猜你喜歡
        劉家
        孫子研究(2022年5期)2023-01-08 01:46:30
        “救命”神器
        劉家魚(yú)鋪
        幼兒100(2022年19期)2022-06-23 00:17:34
        劉家祎 打破少年禁錮 詮釋赤子靈動(dòng)
        劉家成、劉一達(dá):讓京味兒入味兒
        北廣人物(2020年46期)2020-12-11 07:12:40
        羽翼
        藝術(shù)家(2020年6期)2020-08-10 08:35:32
        當(dāng) 我 們 一 起 走 過(guò)
        青年歌聲(2019年6期)2019-06-26 09:11:46
        My Summer Holiday
        媽媽的白發(fā)
        阜新劉家區(qū)煤層氣井調(diào)剖堵水研究與實(shí)踐
        日本护士xxxx视频| 久久精品国产亚洲av桥本有菜| 女同av免费在线播放| 激情五月开心五月啪啪| 无套内射在线无码播放| 日韩人妻无码精品久久免费一 | 美利坚日韩av手机在线| 色视频综合无码一区二区三区| 亚洲五月天综合| 99国产精品无码专区| 久久精品伊人久久精品| 色婷婷久久亚洲综合看片| 国产欧美日韩一区二区三区 | 91偷自国产一区二区三区| 无码人妻精品一区二区三区蜜桃 | 亚欧免费无码aⅴ在线观看| 亚洲av无码成人精品区在线观看| 国产成人亚洲欧美三区综合| 亚洲av成人无网码天堂 | 亚洲av粉嫩性色av| 日本久久精品视频免费| 呦系列视频一区二区三区| 日本公妇在线观看中文版| 青青青伊人色综合久久亚洲综合| 超短裙老师在线观看一区二区| 亚洲一区二区三区偷拍女| 午夜性色一区二区三区不卡视频| 久久久久久久久888| 欧美丝袜秘书在线一区| 国产精品日韩亚洲一区二区| 吃奶摸下高潮60分钟免费视频| 老熟女重囗味hdxx70星空| 色综合色综合久久综合频道| 精品国模人妻视频网站| 日本一区二区三区视频在线观看| 亚洲一区二区三区播放| 熟妇无码AV| 日本二区三区视频在线观看| 亚洲免费国产中文字幕久久久 | 久久天堂综合亚洲伊人hd妓女| 精品人体无码一区二区三区|