我國(guó)人口眾多,由于各種原因,如創(chuàng)傷、腫瘤、先天因素等導(dǎo)致的大塊骨缺損,影響著人們的基本生活及美觀。在臨床工作中,自體骨移植材料以幾乎零成本、高效的骨誘導(dǎo)、骨傳導(dǎo)及成骨能力,成為優(yōu)選材料。然而由于它固有的缺點(diǎn):供區(qū)有限、供區(qū)并發(fā)癥等問(wèn)題明顯[1-2],人們一直在尋找一種能替代自體骨植骨材料的人工材料。但是很多骨科移植物都缺乏內(nèi)在的骨誘導(dǎo)性能,從而不能刺激未分化的多能干細(xì)胞向成骨細(xì)胞方向發(fā)展。骨形態(tài)發(fā)生蛋白 ( bone morphogenetic proteins,BMP )的出現(xiàn)彌補(bǔ)了這一點(diǎn),它成為了最廣泛的骨形成調(diào)控因子[3]。美國(guó)食品和藥物管理局 ( Food and drug administration,F(xiàn)DA ) 已批準(zhǔn)進(jìn)入臨床的 BMP 類產(chǎn)品有 InFUSE Bone Graft ( rhBMP-2 與牛 1 型膠原復(fù)合 )和 OP.1 Putty ( rhBMP-7 與牛膠原復(fù)合 ),它們的臨床應(yīng)用結(jié)果表明,具有很好的促進(jìn)成骨作用[4]。
然而,它們由于制備工藝復(fù)雜、生產(chǎn)周期長(zhǎng)、產(chǎn)率低、價(jià)格昂貴等現(xiàn)實(shí)問(wèn)題不能被中國(guó)大多數(shù)患者所接受[5]。本課題組利用 BMP-2 氨基酸序列中誘導(dǎo)成骨的核心功能區(qū),應(yīng)用固相多肽合成法合成不同組合的 BMPs 序列多肽,該多肽保留了 BMP-2 的骨誘導(dǎo)能力,且無(wú)免疫原性等優(yōu)點(diǎn),該方法具備合成費(fèi)用低的特點(diǎn)。本研究擬通過(guò) SD 大鼠異位成骨實(shí)驗(yàn)進(jìn)一步驗(yàn)證哪種組合的 BMPs 序列多肽具有較好的誘導(dǎo)成骨作用,為該材料的臨床應(yīng)用,提供實(shí)驗(yàn)基礎(chǔ)。
材料與方法
1. 實(shí)驗(yàn)動(dòng)物及實(shí)驗(yàn)材料制備:SD 大鼠,雄性,8 周齡,200~250 g / 只,共 48 只,由解放軍總醫(yī)院第一附屬醫(yī)院實(shí)驗(yàn)動(dòng)物中心提供。
制備好的框架材料羥基磷灰石聚乳酸 ( hydroxyapatite and poly lactic acid,HA / PLA ) 參數(shù)如下:空隙率 80%,平均孔徑 120 m,表觀密度 0.74 g / cm,壓縮強(qiáng)度 1 MPa。無(wú)菌條件下將框架材料切成直徑4 mm / 厚約 1.5 mm 的圓片,用60Co照射 ( 2.5 Mrad )消毒。并將 BMP 活性多肽用雙蒸水溶解,將消毒后的材料浸泡在多肽溶液中 18 h,待多肽溶液完全進(jìn)入材料后取出密封,置于 4 ℃ 保存。本次實(shí)驗(yàn)擬對(duì) BMPIII 與 BMPIV 兩種 BMP 活性多肽復(fù)合HA / PLA 進(jìn)行檢側(cè),并將每種材料復(fù)合多肽的劑量分為 3 種,分別 0.2 g / L、0.4 g / L、0.8 g / L。實(shí)驗(yàn)材料由北京博恩康生物科技有限公司提供,應(yīng)用固相法合成。
多肽序列:BMPI:KIPKASSVPTEL,專利號(hào) 2014101217256;BMPIII:SVPTELSAISTLYL、BMPIV:KIPKASSVPTELSAISTL,專利號(hào):2014101224353。
2. 主要試劑:戊巴比妥鈉購(gòu)自美國(guó) Sigma 公司;伊紅購(gòu)自北京化學(xué)試劑公司;蘇木素購(gòu)自北京化學(xué)試劑公司;改良 Masson 三色染色試劑盒購(gòu)自Leagene 公司。
3. 主要設(shè)備:手術(shù)器械購(gòu)自江蘇三興醫(yī)療器械公司;顯微鏡及碼成像系統(tǒng) ( Olympus BX50、DP50 )。
1. 實(shí)驗(yàn)動(dòng)物分組及手術(shù)方法:應(yīng)用隨機(jī)抽簽法將 48 只 SD 大鼠隨機(jī)分為 8 組 ( A、B、C、D、E、F、G、H 組 ),每組 6 只。8 周齡,200~250 g /只:將 BMPIII 多肽的 3 種濃度 0.2 g / L、0.4 g / L、0.8 g / L 的分別與 HA / PLA 組成的復(fù)合材料植入大鼠體內(nèi),分別為 A、B、C 組;將 BMPIV 多肽的 3 種濃度 0.2 g / L、0.4 g / L、0.8 g / L 分別與 HA / PLA 復(fù)合植入大鼠體內(nèi),分別為 D、E、F 組;植入 0.4 g / L濃度 BMPI 多肽與 HA / PLA 組成的復(fù)合材料的實(shí)驗(yàn)對(duì)照為 G 組,僅植入 HA / PLA 框架材料的空白對(duì)照為 H 組。
用與 SD 大鼠質(zhì)量百分比為 3% 的戊巴比妥鈉溶液靜脈麻醉后,無(wú)菌操作下,充分暴露兩側(cè)臀部肌肉,用手術(shù)刀切開(kāi)臀部肌肉淺層,將材料放入并用不可吸收絲線將傷口縫合。按照實(shí)驗(yàn)分組,術(shù)后自由活動(dòng),分籠飼養(yǎng)。
2. 觀察指標(biāo):( 1 ) 觀察術(shù)后 SD 大鼠活動(dòng)、進(jìn)食、傷口愈合等一般情況。( 2 ) 術(shù)后 3、5 周時(shí)分別對(duì)各組隨機(jī)選取 3 只大鼠麻醉進(jìn)行影像學(xué)檢查,并于檢測(cè)后在麻醉狀態(tài)下注入空氣處死并提取材料標(biāo)本。術(shù)后 3 周攝背部正位 X 線片;術(shù)后 5 周時(shí)進(jìn)行 X 線、CT 照射。( 3 ) 將各組不同時(shí)間段的取材標(biāo)本用 10% 甲醛溶液固定 24 h,硝酸脫鈣 12 h 后,常規(guī)石蠟包埋,經(jīng)切片、HE 染色后在光學(xué)顯微鏡下觀察組織形態(tài)。( 4 ) Masson 染色組織學(xué)觀察新生骨膠原形成 ( 藍(lán)色 ) 并計(jì)算新生骨面積[6]。由于Masson 染色對(duì)新生骨基質(zhì)、植入材料及周圍正常組織顯色層次感明顯,可以顯著區(qū)分膠原和其余組織,故應(yīng)用 Masson 染色對(duì)材料組織進(jìn)行數(shù)據(jù)分析,以明確材料周圍軟骨基質(zhì)分泌及成骨情況[6-7]。應(yīng)用電子顯微鏡在每個(gè)標(biāo)本材料區(qū)域內(nèi)隨機(jī)提取 3 個(gè)視野 ( ×400 ),計(jì)算成骨 ( 膠原 ) 面積。采用 Masson染色成骨面積評(píng)分系統(tǒng)進(jìn)一步對(duì)各組在成骨膠原分泌旺盛時(shí) ( 術(shù)后 5 周 ) 骨誘導(dǎo)活性進(jìn)行組織學(xué)評(píng)分,并將其評(píng)分結(jié)果進(jìn)行秩和平均等級(jí)兩兩比較[8]。未見(jiàn)膠原組織為 0 分,~25% 為 1 分,~50% 為2 分,~75% 為 3 分,~100% 為 4 分,統(tǒng)計(jì)并得出結(jié)果。
應(yīng)用 SPSS 16.0 軟件進(jìn)行統(tǒng)計(jì)學(xué)分析。多組數(shù)據(jù)之間比較采用等級(jí)資料的秩和檢驗(yàn)分析。P<0.05 為差異有統(tǒng)計(jì)學(xué)意義。
結(jié) 果
所有動(dòng)物均順利完成手術(shù)。術(shù)后觀察期間,動(dòng)物飲食、活動(dòng)良好,各組實(shí)驗(yàn)動(dòng)物傷口無(wú)腫脹、無(wú)膿性滲出、愈合良好,動(dòng)物全部存活。植入材料各組硬度均增加。
X 線檢查:術(shù)后 3 周,手術(shù)植入?yún)^(qū) A、B、D、E、G 組均有輕度模糊顯影,C、F 組顯影明顯,H 組未見(jiàn)明顯顯影;術(shù)后 5 周,A、D 組植入?yún)^(qū)內(nèi)有較淺顯影,B、E、G 組有較淺較大顯影,C、F 組顯影較明顯,H 組未見(jiàn)明顯顯影 ( 圖 1~3 )。
圖1 a~c:分別為 A、B、C 組術(shù)后 3 周的 X 線顯像;d~f:分別為 A、B、C 組術(shù)后 5 周的 X 線顯像 (顯示可疑或可見(jiàn)材料成骨 )圖2 a~c:分別為 D、E、F 組術(shù)后 3 周的 X 線顯像;d~f:分別為 D、E、F 組術(shù)后 5 周的 X 線顯像 (顯示可疑或可見(jiàn)材料成骨 )圖3 a:為 G 組術(shù)后 3 周 X 線顯像;b:為 G 組術(shù)后 5 周 X 線顯像;c:為 H 組術(shù)后 5 周 X 線顯像;d:為 H 組術(shù)后 3 周 X 線顯像(顯示可疑或可見(jiàn)材料成骨 )Fig.1 a-c: The X-ray films at 3 weeks after the operation in group A, B and C; d-f: The X-ray films at 5 weeks after the operation in group A, B and C. The suspicious or visible osteogenesis material was showed by theFig.2 a-c: The X-ray films at 3 weeks after the operation in group D, E and F; d-f: The X-ray films at 5 weeks after the operation in group D, E and F. The suspicious or visible osteogenesis material was showed by theFig.3 a: The X-ray film at 3 weeks after the operation in group G; b: The X-ray film at 5 weeks after the operation in group G; c: The X-ray film at 5 weeks after the operation in group H; d: The X-ray film at 3 weeks after the operation in group H. The suspicious or visible osteogenesis material was showed by the
CT 顯示:除 A、D 組可見(jiàn)較模糊低密度顯影外,B、C、E、F、G 組均顯影明顯,H 組未見(jiàn)顯影。為排除框架材料 HA / PLA 未分解的材料對(duì)影像學(xué)影響,將框架材料在體外與大鼠尾骨做對(duì)比進(jìn)行CT 照射,骨窗下僅見(jiàn)極低密度顯影 ( 圖 4~5 )。
1. HE 染色:A、B、C、D、E 及 F 組術(shù)后 3 周可見(jiàn)少量成骨細(xì)胞長(zhǎng)入多孔材料,貼附于孔壁;隨著植入時(shí)間的延長(zhǎng),材料周圍軟骨細(xì)胞活躍,材料逐漸降解,術(shù)后 5 周材料部分降解,其中 B、C 組有較多軟骨基質(zhì)形成,D、E、F 組分泌軟骨基質(zhì)情況與相對(duì)應(yīng)的 A、B、C 組大致相同。G 組術(shù)后 5 周材料也降解,軟骨基質(zhì)形成較多,有較多軟骨細(xì)胞形成;H 組框架材料分解較少,軟骨基質(zhì)形成極少( 圖 6~8 )。
2. Masson 染色及術(shù)后 5 周成骨量評(píng)分比較:術(shù)后 3 周,A、D 組在降解材料周圍僅有少量軟骨膠原形成表現(xiàn)為藍(lán)色,且 B、C 組和 E、F 組軟骨膠原量分別明顯多于 A 組和 D 組,表現(xiàn)為藍(lán)色,可見(jiàn)少許紅染。G 組術(shù)后 3 周藍(lán)色面積較小,而 H 組降解材料周圍軟骨膠原極少。術(shù)后 5 周,A、B、C、D、E 及 F 組藍(lán)色面積明顯多于術(shù)后 3 周,周圍少量紅染,G 組藍(lán)色面明顯增大,而 H 組降解材料周圍軟骨膠原較少,僅見(jiàn)少量藍(lán)色軟骨膠原形成( 圖 9~11 )。
成軟骨膠原面積的 Masson 評(píng)分:B 組 ( 2.22±0.45 ) 分、C 組 ( 2.44±0.35 ) 分明顯大于 A 組 ( 1.06±0.39 ) 分,E 組 ( 2.28±0.25 ) 分、F 組 ( 2.44±0.35 ) 分明顯大于 D 組 ( 0.72±0.25 ) 分,差異有統(tǒng)計(jì)學(xué)意義(P<0.05 );A 組與 D 組的評(píng)分相差不大 (P>0.05 ),而 E、F 組評(píng)分均明顯大于 A 組,B、C 組評(píng)分均明顯大于 D 組,差異有統(tǒng)計(jì)學(xué)意義 (P<0.05 );B、C、E、F 組各組間評(píng)分兩兩比較,差異均無(wú)統(tǒng)計(jì)學(xué)意義(P>0.05 );G 組評(píng)分 ( 2.67±0.30 ) 分較 B、E 組大,差異均有統(tǒng)計(jì)學(xué)意義 (P<0.05 ),而與 C、F 組評(píng)分相差不大 (P>0.05 )。H 組評(píng)分最少,為 ( 0.222±0.27 ) 分,除 D 組外,與其它各組差異均有統(tǒng)計(jì)學(xué)意義 (P<0.05 )。
圖4 a~c:為 A、B、C 組術(shù)后 5 周的 CT 顯像;d~f:為D、E、F 組術(shù)后 5 周的 CT 顯像(顯示可疑或可見(jiàn)材料成骨 )圖 5 a:為框架材料 HA / PLA在體外以鼠尾為對(duì)照的 CT 橫斷面顯像;b:為 G 組術(shù)后 5 周的CT 顯像;c:為 H 組術(shù)后 5 周的 CT 顯像 (顯示可疑或可見(jiàn)材料成骨 )Fig.4 a-c: The CT images at 5 weeks after the operation in group A, B and C; d-f: The CT images at 5 weeks after the operation in group D, E and F. The suspicious or visible osteogenesis material was showed by theFig.5 a: The framework materials HA / PLA were showed in the rat tail in vitro on CT; b:The CT image at 5 weeks after the operation in group G; c:The CT image at 5 weeks after the operation in group H. The suspicious or visible osteogenesis material was showed by the
圖6 a~c:分別為術(shù)后 3 周 A、B、C 組的 HE 染色;d~f:分別為術(shù)后 5 周 A、B、C 組的 HE 染色 (為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )圖 7 a~c:分別為術(shù)后 3 周 D、E、F 組的 HE 染色;d~f:分別為術(shù)后 5 周 D、E、F 組的 HE 染色 (為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )Fig.6 a-c: The HE staining at 3 weeks after the operation in group A, B and C; d-f: The HE staining at 5 weeks after the operation in group A, B and C. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope( ×400 ), and scale bar=100 μmFig.7 a-c: The HE staining at 3 weeks after the operation in group D, E and F; d-f: The HE staining at 5 weeks after the operation in group D, E and F. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope( ×400 ), and scale bar=100 μm
圖 8 a:為術(shù)后 3 周 G 組的 HE 染色;b:為術(shù)后 5 周 G 組的 HE 染色;c:為術(shù)后 5 周 H 組的 HE 染色;d:為 H 組術(shù)后 3 周 HE 染色(為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )圖 9 a~c:分別為術(shù)后 3 周 A、B、C 組的 Masson 染色;d~f:分別為術(shù)后 5 周 A、B、C 組的 Masson 染色 (為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )圖 10 a~c:分別為術(shù)后 3 周 D、E、F 組的 Masson 染色;d~f:分別為術(shù)后 5 周 D、E、F 組 Masson 染色 (為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )圖 11 a:為術(shù)后 3 周 G 組 Masson 染色;b:為術(shù)后 5 周 G 組 Masson 染色;c:為術(shù)后 5 周 H 組 Masson 染色;d:為 H 組術(shù)后 3 周Masson 染色 (為框架材料, 為軟骨基質(zhì)。圖片均為光鏡下 × 400,右下角比例尺長(zhǎng)度 = 100 μm )Fig.8 a: The HE staining at 3 weeks after the operation in group G; b: The HE staining at 5 weeks after the operation in group G; c: The HE staining at 5 weeks after the operation in group H; d: The HE staining at 3 weeks after the operation in group H. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope ( ×400 ), and scale bar=100 μmFig.9 a-c: The Masson staining at 3 weeks after the operation in group A, B and C; d-f: The Masson staining at 5 weeks after the operation in group A, B and C. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope ( ×400 ), and scale bar=100 μmFig.10 a-c: The Masson staining at 3 weeks after the operation in group D, E and F; d-f: The Masson staining at 5 weeks after the operation in group D, E and F. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope ( ×400 ), and scale bar=100 μmFig.11 a: The Masson staining at 3 weeks after the operation in group G; b: The Masson staining at 5 weeks after the operation in group G; c:The Masson staining at 5 weeks after the operation in group H; d: The Masson staining at 3 weeks after the operation in group H. The framework material was marked by theand cartilage matrix was marked by the. Images were observed under the light microscope ( ×400 ), and scale bar=100 μm
討 論
骨形成發(fā)生蛋白 ( BMPs ) 是一組具有類似結(jié)構(gòu)的高度保守的功能蛋白,屬于轉(zhuǎn)化生長(zhǎng)因子 B 超家族成員,是一種多功能的細(xì)胞生長(zhǎng)因子,能夠在體內(nèi)外誘導(dǎo)骨和軟骨形成,是目前骨移植材料中,效果較理想的材料[9]。自 Urist 于 1965 年發(fā)現(xiàn)BMPs[10],BMPs 已經(jīng)被逐漸認(rèn)識(shí),并應(yīng)用重組技術(shù)大量用于生產(chǎn),rhBMP-2 與 rhBMP-7 是現(xiàn)在兩個(gè)僅有的應(yīng)用于國(guó)外臨床的材料[11-12]。這兩個(gè)材料已經(jīng)過(guò)動(dòng)物實(shí)驗(yàn)及臨床實(shí)驗(yàn),證明了它們有效的骨誘導(dǎo)活性,成為可以替代自體骨的移植材料[13]。盡管這兩種材料有強(qiáng)大的骨誘導(dǎo)能力,但由于其制備工藝復(fù)雜、生產(chǎn)周期長(zhǎng)、產(chǎn)率低、價(jià)格昂貴及術(shù)后局部炎性反應(yīng)等問(wèn)題,阻礙了其在臨床的迅速發(fā)展[14-16]。根據(jù) BMP-2 氨基酸序列中 II 型受體具有很多抗原表位,其特征性的“指節(jié)抗原表位”具有誘導(dǎo)成骨的核心功能區(qū)段 ( 20 個(gè)氨基酸 )[17],通過(guò) FMOC 固相多肽合成法合成含 20 多個(gè)氨基酸的寡肽-BMP 活性多肽 ( BMPI、BMPIII、BMPIV ),以便能夠模擬天然骨基質(zhì)的促發(fā)及指導(dǎo)生物礦化,在局部形成偏酸環(huán)境,促進(jìn)局部鈣磷自組裝沉積到體內(nèi)局部組織中膠原纖維表面,生長(zhǎng)成按同一方向排列的堅(jiān)硬羥基磷灰石微型晶體結(jié)構(gòu),形成與天然骨極為相似的結(jié)構(gòu)。
固相合成的優(yōu)點(diǎn)主要表現(xiàn)在,最初的反應(yīng)物和產(chǎn)物都是連接在固相載體上,因此可以在一個(gè)反應(yīng)容器中進(jìn)行所有的反應(yīng),便于自動(dòng)化操作,加入過(guò)量的反應(yīng)物可以獲得高產(chǎn)率的產(chǎn)物,同時(shí)產(chǎn)物很容易分離,能夠有效克服用基因工程技術(shù)制備大分子蛋白質(zhì)時(shí)工藝復(fù)雜、成本高、價(jià)格昂貴的缺點(diǎn);而且活性多肽可發(fā)揮與其蛋白質(zhì)類似的作用,同時(shí)短鏈多肽活性位點(diǎn)能充分暴露并與細(xì)胞表面相應(yīng)的受體結(jié)合,達(dá)到較好的生物活性。Saito 等曾將 BMP-2核心區(qū)的 20 個(gè)氨基酸復(fù)合藻酸鹽水凝膠進(jìn)行異位成骨實(shí)驗(yàn),發(fā)現(xiàn)其效果不如 BMP-2,但優(yōu)于對(duì)照組,在后期實(shí)驗(yàn)中對(duì)多肽進(jìn)行改進(jìn),可于 12 周完成骨缺損修復(fù)[18-19]。Park 等[20]用包含促成骨活性區(qū)域 ( osteopromotive domain,OPD ) 的“DWIVA”序列的具有受體結(jié)合能力的 BMP-2 肽段進(jìn)行骨缺損實(shí)驗(yàn),在 4 周時(shí)有明顯的骨質(zhì)生長(zhǎng)。Zhao 等[21]利用 BMP-2 多肽復(fù)合可注射水凝膠植入大鼠背部肌肉,注射后 6 周 HE 染色可見(jiàn)骨小梁形成,也證明BMP-2 多肽有骨誘導(dǎo)能力。
本課題組以往相關(guān)研究證實(shí)了,BMP-2 活性多肽具有體外定向誘導(dǎo)大鼠 BMSCs 向成骨方向分化的作用[22]。BMP 活性多肽與 BMP 一樣具有生物學(xué)活性,有優(yōu)秀的骨誘導(dǎo)能力[23],但 BMP 活性多肽缺乏力學(xué)強(qiáng)度,且難于塑形。由于 HA / PLA 作為易于塑形且具有適當(dāng)?shù)牧W(xué)性能,而缺乏骨誘導(dǎo)活性的材料。因此,將二者結(jié)合,希望能達(dá)到理想的植骨材料水平。為了評(píng)價(jià) BMP-2 活性多肽復(fù)合 HA / PLA框架架材料在體內(nèi)的活性,本研究根據(jù)在核心功能區(qū)兩側(cè)添加的氨基酸序列不同分為兩個(gè)實(shí)驗(yàn)組,并與前期實(shí)驗(yàn)結(jié)果提示的骨誘導(dǎo)能力較優(yōu)者 ( 0.4 g / L BMPI ) 進(jìn)行對(duì)比,進(jìn)行了異位成骨實(shí)驗(yàn),將負(fù)載了BMPIII、BMPIV 的 3 個(gè)濃度 0.2 g / L、0.4 g / L、0.8 g / L活性多肽的框架材料。結(jié)果顯示:術(shù)后 3 周,實(shí)驗(yàn)組 0.8 g / L 濃度組可見(jiàn)片狀高密度影,而 0.2 g / L、0.4 g / L 濃度組可見(jiàn)輕微的點(diǎn)狀低密度影;術(shù)后 5 周,0.4 g / L、0.8 g / L 濃度組均有新骨形成,片狀高密度影明顯增強(qiáng),接近正常骨組織密度,而 0.2 g / L 濃度組新骨形成量較小,點(diǎn)狀高密度影較淺。為排除框架材料 HA / PLA 對(duì)影像學(xué)影響,將框架材料在體外與大鼠尾骨做對(duì)比進(jìn)行 CT 照射,骨窗下可見(jiàn)極低密度顯影,基本不影響材料在影像學(xué)的觀察。組織學(xué)觀察可見(jiàn),G 組與實(shí)驗(yàn)組 0.8 g / L 濃度組有大量骨膠原形成,可證明其骨組織增長(zhǎng)旺盛。而實(shí)驗(yàn)組的0.2 g / L、0.4 g / L 濃度組骨膠原可見(jiàn)梯度增加,這說(shuō)明 BMPIII 與 BMPIV 材料在 0.2~0.4 g / L 范圍內(nèi)骨膠原分泌會(huì)隨濃度的增加而增加;而 0.4~0.8 g / L時(shí),卻無(wú)明顯骨膠原分泌增加。以上研究結(jié)果表明,BMPIII 與 BMPIV 均有骨誘導(dǎo)活性,且兩者等濃度時(shí)骨誘導(dǎo)活性大致相等 (P>0.05 );G 與 C、F 組骨誘導(dǎo)能力大致相等 (P>0.05 ),均強(qiáng)于 BMPIII、BMPIV 其它濃度 (P<0.05 ),可以證明濃度為BMPIII 與 BMPIV 的 0.8 g / L 組更適于成為骨修復(fù)材料,而 G 組 ( BMPI 0.4 g / L ) 骨誘導(dǎo)能力又較 BMPIII與 BMPIV 更適于成為骨誘導(dǎo)材料。
本研究證明了術(shù)后 5 周各組有成骨,實(shí)驗(yàn)多肽具有骨誘導(dǎo)能力,但其效果距離 InFUSE Bone Graft( rhBMP-2 與牛 1 型膠原復(fù)合 )、OP.1 Putty ( rhBMP-7與牛膠原復(fù)合 ) 仍有不小距離[17-18]。有文獻(xiàn)報(bào)道這些材料可以在術(shù)后 3~4 周局部有新生骨形成,本實(shí)驗(yàn)證明人工多肽在術(shù)后 5 周還處于骨膠原大量分泌期,故仍須將材料進(jìn)一步改良。骨誘導(dǎo)實(shí)驗(yàn)只是材料動(dòng)物實(shí)驗(yàn)的一部分,仍須進(jìn)一步行動(dòng)物體內(nèi)骨缺損材料植入實(shí)驗(yàn)來(lái)驗(yàn)證其成骨能力、生物力學(xué)等性能。
[1] Kretlow JD, Mikos AG. Review: mineralization of synthetic polymer scaffolds for bone tissue engineering. Tissue Eng,2007, 13(5):927-938.
[2] Heary RF, Schlenk RP, Sacchieri TA, et al. Persistent iliac crest donor site pain: independent outcome assessment.Neurosurgery, 2002, 50(3):510-516.
[3] 鄭軍, 齊新生. 骨形態(tài)發(fā)生蛋白在骨缺損和壞死修復(fù)中的成骨機(jī)制和運(yùn)用. 中國(guó)矯形外科雜志, 2004, 12(23):1888-1890.
[4] Bessa PC, Casal M, Reis RL. Bone morphogenetic proteins in tissue engineering: the road from the laboratory to the clinic,part I (basic concepts). J Tissue Eng Regen Med, 2008, 2(1):1-13.
[5] Wang J, Guo J, Liu J, et al. BMP-functionalised coatings to promote osteogenesis for orthopaedic implants. Int J Mol Sci,2014, 15(6):10150-10168.
[6] Yang W, Maolin H, Jinmin Z, et al. High expression of metabotropic glutamate receptor 4: correlation with clinicopathologic characteristics and prognosis of osteosarcoma. J Cancer Res Clin Oncol, 2014,1 40(3):419-426.
[7] 王俊艷, 梁玉. 試用Masson染色評(píng)價(jià)骨組織的成熟程度. 解剖科學(xué)進(jìn)展, 2004, 10(8)17-18.
[8] 郭建剛, 趙然, 等. 骨組織成分與Masson三色染色反應(yīng)的關(guān)系分析. 中醫(yī)正骨, 2001, 13(11)5-6.
[9] Koh JT, Zhao Z, Wang Z, et al. Combinatorial gene therapy with BMP2/7 enhances cranial bone regeneration. J Dent Res,2008, 87(9):845-849.
[10] Urist MR. Bone: formation by autoinduction. Science, 1965,150(3698):893-899.
[11] Buttermann GR. Prospective nonrandomized comparison of an allograft with bone morphogenic protein versus an iliac-crest autograft in anterior cervical discectomy and fusion. Spine J,2008, 8(3):426-435.
[12] Glassman SD, Carreon L, Djurasovic M, et al. Posterolateral lumbar spine fusion with INFUSE bone graft. Spine J, 2007,7(1):44-49.
[13] Glassman SD, Carreon LY, Djurasovic M, et al. RhBMP-2 versus iliac crest bone graft for lumbar spine fusion: a randomized, controlled trial in patients over sixty years of age.Spine, 2008, 33(26):2843-2849.
[14] Song G, Habibovic P, Bao C, et al. The homing of bone marrow MSCs to non-osseous sites for ectopic bone formation induced by osteoinductive calcium phosphate. Biomaterials, 2013,34(9):2167-2176.
[15] Lee KB, Murray SS, Taghavi CE, et al. Bone morphogenetic protein-binding peptide reduces the inflammatory response to recombinant human bone morphogenetic protein-2 and recombinant human bone morphogenetic protein-7 in a rodent model of soft-tissue inflammation. Spine J, 2011, 11(6):568-576.
[16] Wozney JM, Seeherman HJ. Protein-based tissue engineering in bone and cartilage repair. Curr Opin Biotechnol, 2004,15(5):392-398.
[17] Kirsch T, Sebald W, Dreyer MK. Crystal structure of the BMP-2-BRIA ectodomain complex. Nat Struct Biol, 2000, 7(6):492-496.
[18] Saito A, Suzuki Y, Ogata SI, et al. Activation of osteoprogenitor cells by a novel synthetic peptide derived from the bone morphogenetic protein-2 knuckle epitope. Biochim Biophys Acta, 2003, 1651(1-2):60-67.
[19] Saito A, Suzuki Y, Kitamura M, et al. Repair of 20-mm long rabbit radial bone defects using BMP-derived peptide combined with an alpha-tricalcium phosphate scaffold. J Biomed Mater Res A, 2006, 77(4):700-706.
[20] Park JB, Lee JY, Park HN, et al. Osteopromotion with synthetic oligopeptide-coated bovine bone mineral in vivo. J Periodontol,2007, 78(1):157-163.
[21] Zhao J, Fang Z, Huang R, et al. Ectopic osteogenesis in vivo using bone morphogenetic protein-2 derived peptide loaded biodegradable hydroge. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, 2014, 31(4):811-815.
[22] 吳斌, 鄭啟新, 郭曉東, 等. 骨形態(tài)發(fā)生蛋白-2活性多肽修飾的重組膠原礦化骨對(duì)骨髓基質(zhì)干細(xì)胞生物學(xué)行為的影響. 中華創(chuàng)傷骨科雜志, 2008, 10(12).
[23] Kugimiya F, Kawaguchi H, Chung UI. BMP and bone formation. Clin Calcium, 2004, 14(1):173-179.