        Development of noncontacting mechanical measurement system for instruments in laparo-endoscopic single-site surgery with digital image correlation technology

        2011-05-16 06:23:50XUAnanZHUJiangfanSUJinZHANGDongshengWANGQiang
        外科研究與新技術(shù) 2011年2期
        關(guān)鍵詞:經(jīng)臍數(shù)字圖像試驗(yàn)機(jī)

        XU An-an,ZHU Jiang-fan,SU Jin,ZHANG Dong-sheng,WANG Qiang

        1.Department of General Surgery,East Hospital of Tongji University,Shanghai,200120,China;

        2.Department of Mechanics Shanghai University,Shanghai200444,China

        Development of noncontacting mechanical measurement system for instruments in laparo-endoscopic single-site surgery with digital image correlation technology

        XU An-an1,ZHU Jiang-fan1,SU Jin1,ZHANG Dong-sheng2,WANG Qiang2

        1.Department of General Surgery,East Hospital of Tongji University,Shanghai,200120,China;

        2.Department of Mechanics Shanghai University,Shanghai200444,China

        ObjectiveAnalysis of mechanical measurements in laparo-endoscopic single-site surgery(LESS)is an important instrument design and surgical simulator.Aims of this study was to set up and evaluate the reliability and stability of noncontacting mechanical measurement system for instrument of LESS in company with digital image correlation technology.MethodsThe noncontacting mechanical measurement system was connected to a digital image correlation devices and a LESS manipulation platform(set up with a SILS Port and an inanimate laparoscopic trainer box).The correlation between the changes of deformation measurements(displacement and strain calculated by digital image correlation technology)and the change of workload(workout by the universal material testing machine)were evaluated.The experiment was repeated 8 times.ResultsA strong correlation was noticed between the changes of deformation measurements and the change of workload.The correlation coefficient was statistical significant(P <0.001).A high stability was well shown in all repetitions.Conclusions A noncontacting mechanical measurement system has been developed for LESS.Comprehensive mechanical parameters of SILS port can be obtained precisely by the digital image correlation technology.It is reliable and stable for the evaluation of instruments and manipulations in laparo-endoscopic single-site surgery by this system.

        Laparo-endoscopic single-site surgery;Noncontacting measurement system;Digital image correlation technology

        Since the introduction oflaparo-endoscopic single-sitesurgery(LESS)in 2007,it has rapidly gained popularity with surgeonsaswellasthe industry.Almost all traditional laparoscopic surgeries can be performed by the LESS approach,including surgeries for morbid obesity,liver,spleen,and gastrointestinal diseases[1].However,the procedure is more difficult than traditional laparoscopic surgeries due to associated technicalchallenges including laparoscope and instruments crowding around the umbilicus,lossoftriangulation between the two instruments in the operative field and the required ambidexterity ofthe surgeons to adopt relatively difficult maneuvers[2].To overcome these problems in LESS,new instruments and manipulations have been developed[3-4].Although these instrumentations may seem beneficial,they leave one vital question:Do these concepts really benefit laparo-endoscopic singlesite surgery?The aim of our study was to try to set up and evaluate the reliability and stability ofthe noncontacting mechanical evaluation system based on digital image correlation technology for an objective assessment of instrumentations in laparo-endoscopic single-site surgery.

        Materials and Methods

        The noncontacting mechanical measurement system was composed ofthe LESS manipulation platform,a charge-coupled device camera(type:JAI CV-A1),and a straight grasper(YIDA Medical DeviceCo.,Ltd.,Hangzhou,Zhejiangprovince,China).The LESS manipulation platform was set up by a box trainer(Model 200,RUIHONG laboratory equipment Co.,Ltd.,Shanghai,China)and a SILS PortTM(Covidien, Mansfield, MA, USA). A microcomputer-controlled electronic universal testing machine was used to measure the forces trailing the grasper(BZ2.5/TSIS,ZWICK Co.,Ltd.,German.)

        MechanicalTest by the Universal Material Testing Machine

        The grasper,which was inserted in the SILS Port,was connected with the universal testing machine by a fishing wire,and was trailed 50mm with a constant speed of 0.33 mm/s.The traction forces per second were obtained and saved by the attached software.

        Noncontacting Mechanical Test based on Digital Image Correlation Technology.

        The noncontacting mechanical test contained the following steps:

        1.Formation of speckle on the SILS port(Fig.1).

        2.Selection of dominant-points(the right point and the left point,F(xiàn)ig.2).

        3.The grasper was trailed by the universal testing machine(the forces exerted followed the displacement control algorithm).Meanwhile,the transformation of the port was captured by the CCD camera.

        Fig.1 Mechanical test by theuniversal testing machine and the digital image correlation(A:Universal material testing machine,B:grasper,C:box trainer,D:fishing wire,E:SILS port,F(xiàn):fiber optic lights,G:camera)圖1 萬(wàn)能材料試驗(yàn)機(jī)水平牽引實(shí)驗(yàn)與數(shù)字圖像相關(guān)技術(shù)測(cè)試實(shí)驗(yàn)(A:萬(wàn)能材料試驗(yàn)機(jī),B:抓鉗C訓(xùn)練箱 D 牽引線,E:SILS port,F(xiàn):光源,G:攝像機(jī))

        Fig.2 Formation of speckle and selection of dominant-points in the SILS port圖2 散斑制作和紅點(diǎn)選取

        As the grasperwas trailed by the universal testing machine,transformation of the SILS Port’s surface was captured by the CCD camera with the frequency of 1 Hz.Then,the commercialsoftware (the MATFOLT CO Ltd,Shanghai)was used to store a series of images acquired by the camera in digital form and perform image analysis to extract full-field shape and deformation measurements(vertical and horizontaldisplacement and strain data).This experiment was repeated for 8 times.

        Statistical analysis

        Although different vertical and horizontal displacements were obtained for the left and right dominant-points,the changing trends were the same as the dominant-points in the SILS port.Due to this,statistical analyses were conducted only for the left dominant-point.As allthe measurements were continuous variables,The Pearson correlation analysis was conducted to investigate the relationship between the changes of deformation measurements(displacement and strain calculated by digital image correlation technology)and the change of workload(workout by the universal material testing machine).

        All statistical analyses were conducted by using SPSS statistical software(version 15.0;SPSS,Inc.,Chicago,IL,USA).Statistical significance was set,and p-value was defined as<0.05.

        Results

        Table1 shows the results of the experiments which were repeated for8 times.The Pearson correlation coefficients between the changes of deformation measurements(displacement and strain)and the change of workload were very high(│r│ >0.8,P < 0.01).Extremely similar stability results appeared in all repetitions of the procedure as shown in table 1.Due to the high similarity of the results,we chose one of the repetitions(the fifth one)to visualize it in scatterdiagrams as seen in Fig.3 -5.

        Table.1 The Pearson correlation analysis(correlation coefficient:r)between the changes of displacement andstrain and the change of workload in all repetitions of the experiment表1 8次重復(fù)實(shí)驗(yàn)載荷與應(yīng)變及位移的Pearson相關(guān)分析

        Fig.3 Scatterdiagram of the fifth experiment showing the linear correlation between load and strain圖3 載荷與應(yīng)變的散點(diǎn)圖

        Fig.4 Scatterdiagram of the fifth experiment showing the linear correlation between load and horizontal displacement(Hdisplacement)圖4 載荷與水平位移的散點(diǎn)圖

        Fig.5 Scatterdiagram of the fifth experiment showing the linear correlation between load and vertical displacement(Vdisplacement)圖5 載荷與垂直位移的散點(diǎn)圖

        Discussion

        As with most new surgical techniques,the early development oflaparo-endoscopic single-site surgery(LESS)was fraught withproblems:alossof triangulation,clashing of instruments and the instruments with the telescope and camera head,and a lack of maneuverability.New instruments and manipulations were developed by the pioneers to enable surgeons to overcome these difficulties.However,whether these improvements benefit LESS was lacking of objective evaluation.There have been several researches attempted to assess the benefit[5-6],as the measurements were subjective indexes included the operation success rates,errors,and so on,lacking of definite and objective assessment criteria.We set up a contacting mechanical evaluation platform to compare the articulating instruments and the crosshanded manipulation with conventional instruments.Study indicates that more force and time are needed by using cross-handed manipulation in LESS[7].However,contacting mechanicalcomponentslike sensor or gauge used in aforementioned researches were vulnerable to external environmental interference during measurement.Therefore,as a whole they can’t reflect more comprehensive Mechanics changes.

        Digital image correlation(DIC),an advanced noncontacting measurement system,has seen explosive growth in the past two decades.In recent years,the method has been modified and extended to encompass a breathtaking number of novel measurement systems.The term digital image correlation refers to the class of noncontacting methods that acquire images of an object,store images in digital form,and perform image analysis to extract full-field shape and deformation measurements.Within the broad field of image analysis,digital image correlation is generally considered a sub-set of digital image registration techniques.The technique can be used to measure and observe the local mechanical behavior(displacement and strain)in natural and semi-natural texture of different materials like metals,ceramics and polymers[8-9].In biomechanics,DIC are widely used in evaluation for dental restorations and prosthesis,bone repair materials[8-9].

        In this study,basing on the DIC technology,we aimed to set up a reliable noncontacting mechanical measurement system to evaluate instruments in LESS.According to the repeated experimental results of currentstudy,two importantconclusionscan be drawn. First, the noncontacting mechanical measurement system based on DIC technology system is proven to be reliable,as the measurement results almost show a perfect linear correlation with the objective criteria (the universalmaterialtesting machine).Second,an extreme similarity of the results appeared in all repetitions of the experiment demonstrating the high stability of the measurement system.

        Due to the high reliability and stability,there are several applications for the newly developed noncontacting mechanical measurement system.The objective and comprehensive measurements will provide a good feedback tool for evaluation of new instruments and manipulations in LESS.In addition,the system’s use in experimental practice would help to refine movement and tissue handling in LESS teaching and training purposes.Moreover,it can also be used to define force patterns incurred during certain surgical postures and the effect of muscle fatigue.The combination of force pattern and parameters of mental workload can be used to indicate the levelof psychological stress during surgical procedures.

        With the reliable and stablenoncontacting mechanicalmeasurementsystem,LESS willbe spurred on by rapid advances in technology and better instrumentation.

        [1] Zhu JF.Scarless endoscopic surgery:NOTES or TUES[J].Surg Endosc,2007,21(10):1898 -1899.

        [2] Zhu JF.Transumbilicalendoscopic surgery:History,present situation and perspectives[J].World J Gastrointest Endosc,2011,3(6):107 -109.

        [3] Kommu SS,Kaouk JH,Rane A.Laparo-endoscopic single-site surgery:preliminary advances in renal surgery[J].BJU Int,2009,103(8):1034 -1037.

        [4] Joseph RA,Goh AC,Cuevas SP,et al.Chopstick surgery:a novel technique improves surgeon performance and eliminates arm collision in robotic single-incision laparoscopic surgery[J].Surg Endosc,2010,24(6):1331 -1335.

        [5] Botden S,Strijkers R,F(xiàn)ransen S,et al.The use of curved vs.straight instruments in single port access surgery on standardized box trainer tasks[J].Surg Endosc,2011,25(8):2703 - 2710.

        [6] Stolzenburg JU,KallidonisP,Oh MA,etal.Comparative assessment of laparoscopic single-site surgery instruments to conventional laparoscopic in laboratory setting[J].J Endourol,2010,24(2):239 -245.

        [7] Zhu JF,Xu An An.Can cross-handed approach improve maneuver in transumbilical laparoscopic surgery?[J].Surg Endosc,2013,27(4):1444 -1445.

        [8] Dongsheng Zhang,S Mao,C Lu,ElaineRomberg,etal.Dehydration and the Dynamic Dimensional Changes within Dentin and Enamel[J].Dental Materials,2009,25(7):937-945.

        [9] Nazari A,Bajaja D,Zhang D,Romberg E,et al.Aging and the reduction in fracture toughness of human dentin[J].Journal of the Mechanical Behavior of Biomedical Materials,2009,2(5):550-559.

        經(jīng)臍入路腹腔鏡手術(shù)操作非接觸式力學(xué)評(píng)估平臺(tái)的建立*

        徐安安1,朱江帆1,蘇 金1,張東升2,王 強(qiáng)21同濟(jì)大學(xué)附屬東方醫(yī)院微創(chuàng)外科,上海 200120;2上海大學(xué)力學(xué)系,上海 200444

        目的 本研究旨在建立基于數(shù)字圖像相關(guān)技術(shù)的非接觸式力學(xué)測(cè)試評(píng)估平臺(tái),明確其在經(jīng)臍入路腹腔鏡手術(shù)操作評(píng)估中的可靠性。方法 用腹腔鏡模擬訓(xùn)練箱和SILS Port組建經(jīng)臍入路腹腔鏡手術(shù)操作平臺(tái)。分析基于數(shù)字圖像相關(guān)技術(shù)評(píng)估平臺(tái)得到的位移與應(yīng)變分量改變與客觀標(biāo)準(zhǔn)——萬(wàn)能材料試驗(yàn)機(jī)水平牽引載荷改變的相關(guān)性。結(jié)果 本實(shí)驗(yàn)中8次重復(fù)實(shí)驗(yàn)的研究結(jié)果均顯示,由數(shù)字圖像相關(guān)技術(shù)得到的位移與應(yīng)變分量改變與萬(wàn)能材料試驗(yàn)機(jī)牽引實(shí)驗(yàn)載荷改變呈強(qiáng)相關(guān),且相關(guān)系數(shù)有統(tǒng)計(jì)學(xué)意義(P<0.001)。結(jié)論 基于三維數(shù)字圖像相關(guān)技術(shù)的非接觸式力學(xué)測(cè)試方法反映了器械進(jìn)行操作時(shí)SILS port發(fā)生的綜合性力學(xué)參數(shù)改變,方法可靠,適用于經(jīng)臍入路腹腔鏡手術(shù)器械與操作方法評(píng)估。

        經(jīng)臍入路腹腔鏡手術(shù);力學(xué)評(píng)估平臺(tái);數(shù)字圖像相關(guān)技術(shù)

        R 656

        A

        2095-378x(2013)02-0090-04

        浦東新區(qū)重點(diǎn)發(fā)展學(xué)科項(xiàng)目資助(PWZxk2010-07)

        徐安安(1982-),男,主治醫(yī)師,碩士研究生,主要從事普外科常見疾病的微創(chuàng)治療研究。

        作者簡(jiǎn)介:朱江帆(1955-),男,河北人,教授博士生導(dǎo)師,研究腹腔鏡外科的臨床與實(shí)驗(yàn)研究。E-mail:zhujiangfan@hotmail.com

        猜你喜歡
        經(jīng)臍數(shù)字圖像試驗(yàn)機(jī)
        經(jīng)臍單孔腹腔鏡在小兒急性闌尾炎手術(shù)中的應(yīng)用
        鐵路軸承試驗(yàn)機(jī)
        哈爾濱軸承(2020年2期)2020-11-06 09:22:28
        接觸疲勞試驗(yàn)機(jī)伺服電動(dòng)缸加載系統(tǒng)設(shè)計(jì)
        哈爾濱軸承(2020年1期)2020-11-03 09:16:08
        ARGUS-100 藝術(shù)品鑒證數(shù)字圖像比對(duì)系統(tǒng)
        3D與2D腹腔鏡懸吊式經(jīng)臍全子宮切除術(shù)的對(duì)比研究
        經(jīng)臍單孔腹腔鏡在普外手術(shù)中的應(yīng)用分析
        基于塊效應(yīng)測(cè)度的JPEG數(shù)字圖像盲取證
        橡膠整體式履帶動(dòng)態(tài)嚙合試驗(yàn)機(jī)的設(shè)計(jì)
        經(jīng)臍單孔腹腔鏡膽囊切除術(shù)治療膽囊結(jié)石的臨床效果
        數(shù)字圖像修復(fù)在圖像壓縮上的應(yīng)用
        久久夜色精品国产噜噜噜亚洲av| 岛国成人在线| 国产亚洲精品性爱视频| 小黄片免费在线播放观看| 人妻熟妇乱又伦精品hd| 99久久人人爽亚洲精品美女| 国产免费人成视频在线播放播| 中文字幕一区二区三区亚洲 | 亚洲人成综合第一网站| 痉挛高潮喷水av无码免费| 成人a在线观看| 中文字幕亚洲精品一二三区| 国产精品一区二区三区自拍| 色先锋av资源中文字幕| 亚洲综合偷自成人网第页色| 亚洲一区二区av免费观看| 国产猛烈高潮尖叫视频免费| 精品久久久久久777米琪桃花| 国产精品亚洲ΑV天堂无码| 日本视频一区二区三区在线| 最新日本一道免费一区二区| 成人欧美一区二区三区白人| 日韩国产有码精品一区二在线 | 欲色天天网综合久久| 久久夜色精品国产亚洲噜噜| 在线亚洲日本一区二区| 亚洲国产精品无码专区在线观看| 亚洲国产成人精品女人久久久| 日本一级淫片免费啪啪| 日韩av一区二区网址| 一本一道久久a久久精品综合| 在线看片国产免费不卡| 亚洲一区二区三区成人网| 绝顶潮喷绝叫在线观看| 精品国产福利在线观看网址2022 | 欧美成人小视频| 青青青草视频手机在线| 亚洲av无码无线在线观看| 国产av国片精品| av在线网站手机播放| 免费观看91色国产熟女|