        Application of a modified surgical position in anterior approach for total cervical artificial disc replacement

        2020-04-22 07:13:00WenXiuHouHaoXuanZhangXiaWangHaiLingYangXiaoRongLuan
        World Journal of Clinical Cases 2020年1期
        關(guān)鍵詞:頂風(fēng)新動(dòng)向群眾監(jiān)督

        Wen-Xiu Hou,Hao-Xuan Zhang,Xia Wang,Hai-Ling Yang,Xiao-Rong Luan

        Wen-Xiu Hou,Xia Wang,Xiao-Rong Luan,Third Ward of Orthopedics Department,Qilu Hospital,Shandong University,Jinan 250012,Shandong Province,China

        Hao-Xuan Zhang,Department of Spine Surgery,Shandong Provincial Qianfoshan Hospital,The First Affiliated Hospital of Shandong First Medical University,Jinan 250014,Shandong Province,China

        Hai-Ling Yang,Department of Nursing,Qilu Hospital,Shandong University,Jinan 250012,Shandong Province,China

        Abstract

        Key words: Anterior approach;Surgical position;Total cervical artificial disc replacement;Cervical spondylosis

        INTRODUCTION

        Artificial cervical disc prosthesis was designed by utilizing bionics technology,thus preserving the activity of the treated segment,and its design was first reported by Goffinet al[1]in 2002.Total cervical artificial disc replacement (TDR) has been considered a safe and effective alternative surgical treatment for cervical spondylosis and degenerative disc disease that have failed to improve with conservative methods[2-9].

        Positioning the surgical patient is a critical part of the procedure.Appropriate patient positioning is crucial not only for the safety of the patient but also for optimizing surgical exposure,ensuring adequate and safe anesthesia,and allowing the surgeon to operate comfortably during lengthy procedures[10,11].

        The surgical posture is the traditional position used in anterior cervical approach;in general,patients are in a supine position with a pad under their shoulders and a ring-shaped pillow under their head[12,13].The activity of the adjacent segment accelerates the degeneration of the adjacent layers and causes new symptoms[8,14-17].

        To enable an improved TDR procedure,shorten the time of operation,reduce the incidence of perioperative complications,and improve the safety of the procedure,we planned to improve the traditional surgical position in anterior cervical approach.

        In this study,a total of 48 cervical spondylosis patients who were treated by TDR with either the traditional or the modified surgical position were assessed.We comprehensively determined the clinical outcomes,including the blood pressure and heart rate before and after body positioning,position setting time,total operation time,and intraoperative blood loss.

        MATERIALS AND METHODS

        Patients

        All patients were initially assessed and treated by trained nurses before being enrolled in this study.Patients received a diagnosis of cervical spondylosis of one segmental level that was supported by clinical symptoms and imaging data and had poor clinical outcomes even after previously undergoing strict conservative treatment for at least three months.

        Study design and parameters

        Forty-eight patients were divided into a traditional position group and a modified position group,with 24 patients in each group (Table 1).Perioperative parameters were retrospectively analyzed.

        To assess the safety of the position setting process,blood pressure and heart rate were used,and these metrics were measured in all patients before and after the position setting process in both groups.In addition,the surgical position setting time was measured.After surgery,total operation time and intraoperative blood loss were recorded to evaluate the effects of surgical position on the safety of surgery.

        Surgical position setting

        Traditional position group:The traditional surgical position setting is shown in Figure 1A and B.After anesthesia intubation,the patient's head,neck,and shoulders were lifted,a shoulder pad was placed under the shoulders,and a ring-shaped pillow was placed under the head.Subsequently,the patient was positioned back on the table,and the height and position of the head,neck,and shoulder were checked until the neck was fully exposed.

        Modified position group:The modified surgical position setting is shown in Figure 1C and D.After anesthesia intubation,a shoulder pad and a ring-shaped pillow were placed under the shoulder and head,respectively.Then,a soft pillow with a height of approximately 10 cm was placed under the patient's neck.The lower jaw was pulled in the rostral direction,both shoulders were pulled in the caudal direction,and tape was used to maintain the position.

        Statistical analysis

        Data are presented as the mean ± SD.Statistical analyses were performed by the independent-samplest-test between two groups using SPSS (version 22.0,Chicago,IL),and categorical variables were analyzed by the Mann-WhitneyUtest.Differences ofP< 0.05 were considered significant.

        RESULTS

        General patient information

        All patients who underwent single-level Mobi-C artificial disc replacement from September 2014 to September 2015 were included (28 males and 20 females).The average age was 45.7 years (range,25-65 years).Of the patients,8 had C3-C4 replacement,22 had C4-C5 replacement,and 18 had C5-C6 replacement.

        There was no significant difference in sex,age,history,treated segment,anesthesia,or surgical staff between the two groups (P> 0.05).

        Blood pressure and heart rate before and after body positioning

        In the traditional position group,the blood pressure was 124.76 ± 15.3 mmHg before body positioning and 126.69 ± 18.7 mmHg after body positioning (Figure 2A).The average heart rate was 76.36 ± 14.2 bpm and 78.01 ± 13.8 bpm in the traditional position group before and after body posture,respectively (Figure 2B).

        In the modified position group,the blood pressure before body positioning was 128.43 ± 18.8 mmHg,and it was 129.33 ± 17.1 mmHg after body positioning (Figure 2A).The average heart rate was shown to be 82.61 ± 15.0 bpm and 83.25 ± 14.4 bpm in the modified position group before and after body posture,respectively (Figure 2B).

        Blood pressure and heart rate before and after body positioning were not significantly different within each group or between the two groups (P> 0.05).

        Surgical position setting time and total operation time

        The surgical position setting time was 1.85 ± 0.49 min in the traditional position group,and it was 4.57 ± 0.67 min in the modified position group (Figure 3).A statistically significant increase was observed in the modified position group compared with the traditional position group (P< 0.05).

        The total operation time was significantly shorter in the modified position group(82.05 ± 12.4 min) than in the traditional position group (95.78 ± 14.5 min) (P< 0.05)(Figure 3).

        Intraoperative blood loss

        Table1 Demographic characteristics of the patients

        The intraoperative blood loss in the modified position group (20 ± 8.1 mL) was significantly lower than that in the traditional position group (27 ± 7.5 mL;P< 0.05)(Figure 4).

        DISCUSSION

        Artificial cervical disc prosthesis was designed to reconstruct or maintain the height of the intervertebral disc,maintain the regular activity of the cervical spine,and create favorable conditions for the recovery of function of the spinal cord after the spinal cord compression was removed[4,18-20].

        An appropriate surgical position is crucial for the operation.Improvement in the patient's surgical status facilitates the surgeon's procedure and reduces the amount of bleeding and the incidence of complications,thus creating essential conditions for successful implementation of the disc and recovery of the patient[10,11].

        In this study,48 cases of cervical disc replacement with Mobi-C prosthesis were included.Compared with patients in the traditional surgical position,patients in the modified surgical position had more satisfactory clinical outcomes,and the advantages are as follows.

        對(duì)此,采訪中,多地紀(jì)檢干部也向本刊記者表示,對(duì)于群眾身邊的形式主義、官僚主義等直觀的或“變種”的“四風(fēng)”問(wèn)題,紀(jì)委監(jiān)委會(huì)嚴(yán)查不松勁?!皩?duì)頂風(fēng)違紀(jì)問(wèn)題加大監(jiān)督檢查力度,嚴(yán)查快辦,并實(shí)行責(zé)任倒查,嚴(yán)肅追究黨組織主體責(zé)任和紀(jì)檢組織的監(jiān)督責(zé)任,同時(shí)對(duì)典型問(wèn)題通報(bào)曝光,形成有力震懾?!苯鼇?lái),各地通過(guò)不斷豐富監(jiān)督檢查手段,通過(guò)常規(guī)檢查、大數(shù)據(jù)篩查、群眾監(jiān)督等方式,密切關(guān)注“四風(fēng)”隱形變異、改頭換面等新動(dòng)向,其目的都是很明確的,那就是嚴(yán)防“四風(fēng)”反彈回潮。

        To facilitate the operation and select the appropriate type of prosthesis in TDR,the patient is typically placed in the supine-neutral surgical position to maintain the natural curve of the cervical spine[8,21-27].Because only the shoulder pad and ringshaped pillow were placed under the shoulders and head,respectively,the neck of the patient was not supported in the traditional surgical position during anterior cervical approach.However,in the modified position,the shoulder pad and ringshaped pillow were placed under the shoulders and head,respectively,and a soft pillow with a height of approximately 10 cm was placed under the patient's neck so that the patient was in the supine-neutral surgical position during the surgery.

        Patients with the modified surgical position are fixed firmly and securely

        During a cervical surgical procedure,slight activity of the patient can have serious consequences,including cervical displacement and injuries of the blood vessels and the spinal cord[15,23,28-32].In the modified position,the lower jaw and both shoulders were pulled in the rostral and the caudal directions,respectively,and wide tape was used for auxiliary fixation.Thus,the cervical spine and other parts of the patient were securely fixed,allowing a successful surgery and guaranteeing the safety of the patients.

        Reduced total operative time and intraoperative blood loss

        The total operation time was significantly shorter in the modified position group than in the traditional position group.Intraoperative blood loss in the modified position group was significantly lower than that in the traditional position group.

        The modified surgical position needs more surgical position setting time.However,the total operation time was shortened,and intraoperative blood loss was reduced in patients with the modified surgical position compared with patients with the traditional position.A shorter operation time results in a lower operation risk,and a smaller amount of bleeding during the operation can not only help the surgeon's activity but also reduce the risk of injury in patients,which is beneficial to the healing process.

        In this study,the modified surgical position in anterior approach was successfully designed for TDR.The results indicated that the modified surgical position had no adverse effects on the blood pressure and heart rate of the patient.The modified surgical position reduces the total operation time and intraoperative blood loss,although it consumes more surgical position setting time;these results suggest that the modified position is beneficial to the operation of the surgeons,and it is worthy of application and widespread use in TDR.

        Figure1 Surgical position setting.

        Figure2 Patients' blood pressure and heart rate before and after body positioning.

        Figure3 Position setting time and total operation time in the two groups.

        Figure4 lntraoperative blood losses in the two groups.

        ARTICLE HIGHLIGHTS

        Research background

        Total cervical artificial disc replacement (TDR) has been considered a safe and effective alternative surgical treatment for cervical spondylosis and degenerative disc disease that have failed to improve with conservative methods.

        Research motivation

        Positioning the surgical patient is a critical part of the procedure.Appropriate patient positioning is crucial not only for the safety of the patient but also for optimizing surgical exposure,ensuring adequate and safe anesthesia,and allowing the surgeon to operate comfortably during lengthy procedures.The surgical posture is the traditional position used in anterior cervical approach;in general,patients are in a supine position with a pad under their shoulders and a ring-shaped pillow under their head.The activity of the adjacent segment accelerates the degeneration of the adjacent layers and causes new symptoms.

        Research objectives

        To investigate the clinical outcomes of the use of a modified surgical position versus the traditional surgical position in anterior approach for TDR.

        Research methods

        In the modified position group,patients had a soft pillow under their neck,and their jaw and both shoulders were fixed with wide tape.The analyzed data included intraoperative blood loss,position setting time,total operation time,and perioperative blood pressure and heart rate.

        Research results

        Blood pressure and heart rate were not significantly different before and after body positioning in both groups.Compared with the traditional position group,the modified position group showed a statistically significantly longer position setting time.However,the total operation time and intraoperative blood loss were significantly reduced in the modified position group compared with the traditional position group.

        Research conclusions

        The clinical outcomes indicated that total operation time and intraoperative blood loss were lower in the modified position group than in the traditional position group,thus reducing the risks of surgery while increasing the position setting time.

        Research perspectives

        The modified surgical position is a safe and effective method to be used in anterior approach for TDR surgery.

        猜你喜歡
        頂風(fēng)新動(dòng)向群眾監(jiān)督
        咱村有了新動(dòng)向
        黃河之聲(2021年4期)2021-05-15 01:53:00
        軌頂風(fēng)道預(yù)制構(gòu)件力學(xué)性能加載試驗(yàn)研究
        新動(dòng)向
        廣州化工(2020年5期)2020-04-01 01:24:38
        之所以
        雜文選刊(2020年1期)2020-01-10 07:05:03
        黨內(nèi)監(jiān)督和群眾監(jiān)督相結(jié)合的邏輯理路與實(shí)現(xiàn)路徑
        完善群眾監(jiān)督的價(jià)值指向和思路
        各地“搶人大戰(zhàn)”折射哪些新動(dòng)向
        中央蘇區(qū)群眾監(jiān)督制度建設(shè)的歷史考察與現(xiàn)實(shí)啟示
        湖湘論壇(2016年1期)2016-12-01 04:21:55
        一些新動(dòng)向說(shuō)明了什么
        鏈家“頂風(fēng)”融資
        在线观看免费人成视频色9| 亚洲成av人片极品少妇| 国产精华液一区二区三区| 亚洲av日韩av在线观看| 99精品电影一区二区免费看| 国产AV无码无遮挡毛片| 国产一区二区三区免费视| 国产大片内射1区2区| 无码国产午夜福利片在线观看| 国产精品玖玖玖在线资源| 国产av在线观看91| 最新露脸自拍视频在线观看| 熟女体下毛毛黑森林| 亚洲最大成av人网站| 国产日韩乱码精品一区二区| 久久精品国产91精品亚洲| 在线看片免费人成视频久网下载 | 亚洲自偷自拍另类图片小说| 美腿丝袜一区二区三区| 日本一区二区免费在线看| 日本高清视频永久网站www| 国产精品国语对白露脸在线播放 | 91精品亚洲熟妇少妇| 午夜不卡无码中文字幕影院| 236宅宅理论片免费| 制服丝袜人妻中出第一页| 加勒比久久综合久久伊人爱| 少妇扒开毛茸茸的b自慰| 热の国产AV| 人妻在线中文字幕视频| 国产成人久久精品一区二区三区 | 国产精品久久久精品三级18 | 丰满人妻无套内射视频| 久久综合99re88久久爱| 日韩在线一区二区三区免费视频 | 国产精品永久免费视频| 91极品尤物在线观看播放| 中国黄色一区二区三区四区| 午夜精品久久久久久99热| 美女一级毛片免费观看97| 国产在线观看黄片视频免费|