        泵站前池倒T形底坎整流措施數(shù)值模擬

        2018-07-05 08:54:00夏臣智成立焦偉軒張帝
        南水北調(diào)與水利科技 2018年2期
        關(guān)鍵詞:前池流態(tài)數(shù)值模擬

        夏臣智 成立 焦偉軒 張帝

        摘要:為了改善泵站前池邊側(cè)大面積回漩不良流態(tài),基于商用CFD軟件Fluent,運(yùn)用NS方程和Reliable kε紊流模型對加倒T形底坎的前池進(jìn)行數(shù)值模擬,分析倒T形底坎的幾何參數(shù)對前池流態(tài)和邊側(cè)流速的影響。結(jié)果表明:無整流措施時,前池中流態(tài)紊亂,通過加設(shè)倒T形底坎可顯著改善前池中的流態(tài),提高邊側(cè)機(jī)組的流速,改善前池中流速分布均勻度;倒T形底坎設(shè)置在前池中的位置和其上部結(jié)構(gòu)的尺寸對前池整流效果有明顯的影響;倒T形底坎的位置距進(jìn)水池入口75D,上部結(jié)構(gòu)高為04H,寬為01B,前池中流態(tài)得到明顯改善,邊側(cè)回漩范圍減小。

        關(guān)鍵詞:前池;泵站;數(shù)值模擬;倒T形底坎;流態(tài)

        中圖分類號:TV131文獻(xiàn)標(biāo)志碼:A文章編號:

        16721683(2018)02014605

        Abstract:

        In order to rectify the bad flow pattern at the forebay of the pump station,in this paper we conducted numerical simulation of the forebay with inverted Tshaped sill based on the Fluent software using the NS equation and Reliable [WTB1X]k[WTBX]ε turbulence model,and analyzed the influence of the geometrical parameters of the sill on the flow pattern and lateral flow velocity at the forebay.The results showed that without the rectification measure,the flow pattern at the forebay was turbulent.Adding an inverted Tshaped sill could significantly increase the flow rate of the side unit and improve the uniformity of the velocity distribution at the forebay.The location parameter and superstructure size of the inverted Tshaped sill had significant influence on the flow pattern at the forebay.The recommended location of the inverted Tshaped sill is 75D to the entrance of the intake pool.The recommended superstructure is 0.4H high and 01B wide.

        Key words:

        forebay;pump station;numerical simulation;inverted Tshaped sill;flow pattern

        前池是泵站建筑物中的一個重要組成部分,其設(shè)計(jì)的優(yōu)劣關(guān)系到水流能否從引水渠平順擴(kuò)散到進(jìn)水池。設(shè)計(jì)不當(dāng)?shù)那俺刂谐4嬖诖髤^(qū)域的回流,使得水泵的能量和汽蝕性能下降,嚴(yán)重時甚至?xí)鹚闷g和振動,危害泵站安全。同時回流的存在會使得前池內(nèi)有泥沙淤積的問題,進(jìn)一步惡化進(jìn)水條件[14]。

        目前,國內(nèi)外的學(xué)者對前池流態(tài)改善做了大量研究,整流措施主要包括增加前池長度、增大前池?cái)U(kuò)散角、設(shè)置底坎、立柱或壓水板等[510]。馮旭松[11]通過試驗(yàn)分析了常規(guī)形式底坎的整流機(jī)理。成立[12]采用CFD軟件從二維上分析了底坎整流機(jī)理。羅燦[13]采用CFD軟件從三維分析了常規(guī)形式底坎的整流機(jī)理。已有的研究表明設(shè)置底坎對前池中的流態(tài)有明顯的改善,但是未見通過底坎提高前池邊側(cè)的水流流速的研究成果。而有研究表明前池邊側(cè)流速過低,會極大地影響邊側(cè)機(jī)組的運(yùn)行效率,并使得邊側(cè)發(fā)生泥沙淤積更加惡化邊側(cè)機(jī)組的進(jìn)水流態(tài)[1420]。本文針對多機(jī)組泵站前池的擴(kuò)散角過大,誘發(fā)大面積回漩不良流態(tài),邊側(cè)機(jī)組的流速過低,研究了倒T形底坎幾何參數(shù)對改善前池的水流流態(tài)和邊側(cè)機(jī)組的流速分布的影響。

        1前池及倒T形底坎幾何參數(shù)

        本文研究進(jìn)水正向擴(kuò)散前池,其模型如圖1所示,主要有涵洞、前池、進(jìn)水池(1號-10號)和吸水管。

        2數(shù)值計(jì)算方法及邊界條件

        泵站前池內(nèi)流動為不可壓縮湍流流動,該流動可用雷諾時均NS方程和連續(xù)性方程描述。由于前池內(nèi)流動為強(qiáng)曲率流動,采用Reliable [WTB1X]k[WTBX]ε紊流模型要優(yōu)于標(biāo)準(zhǔn)[WTB1X]k[WTBX]ε紊流模型[2123]。

        本文基于商用軟件Fluent,采用分離求解器求解離散方程組,采用SIMPLEC算法,求解精度為二階。采用分塊網(wǎng)格技術(shù),對前池和涵洞采用六面體網(wǎng)格劃分,對結(jié)構(gòu)復(fù)雜的進(jìn)水池采用四面體網(wǎng)格劃分[2425]。通過網(wǎng)格無關(guān)性分析,當(dāng)網(wǎng)格節(jié)點(diǎn)數(shù)量大于2×106時,計(jì)算結(jié)果趨于穩(wěn)定。計(jì)算模型見圖4。

        取涵洞的入口側(cè)為質(zhì)量進(jìn)口,流量為334 L/s。取出水管的出口側(cè)為自由出流出口。固體壁面處設(shè)置為標(biāo)準(zhǔn)壁面函數(shù),且無滑移條件(X、Y、Z方向上的分速度均為0)。自由表面設(shè)為對稱邊界條件。

        3研究方案

        本文研究了倒T形底坎幾何參數(shù)對前池里水流改善,共8種方案。其中方案1為不加任何措施的方案,方案2、3和4分別研究倒T形底坎位置變化對前池進(jìn)水流態(tài)影響。方案5、6、7和8分別研究倒T形底坎上部結(jié)構(gòu)的頂寬和高度對前池進(jìn)水流態(tài)影響。具體幾何參數(shù)見表1。倒T形底坎的上部結(jié)構(gòu)正對6號泵組。

        4計(jì)算結(jié)果及分析

        4.1方案[STBZ]1數(shù)模與試驗(yàn)對比

        圖5為方案1計(jì)算流線圖。由圖可見,無整流措施時,前池兩側(cè)存在兩個大尺度的回流區(qū),圖中順?biāo)鞣较蛴覀?cè)回流區(qū)面積較左側(cè)的回流區(qū)大,主流偏向圖中前池的左側(cè),進(jìn)水池流態(tài)紊亂,不僅影響進(jìn)水池的進(jìn)水流態(tài),而且還容易造成前池內(nèi)的泥沙淤積,嚴(yán)重影響泵站的運(yùn)行效率。

        4.2倒T形底坎幾何參數(shù)對流態(tài)影響

        圖7-圖13為倒T形底坎幾何參數(shù)方案前池計(jì)算流線圖。當(dāng)在前池中加入倒底坎后,前池兩側(cè)的大尺度回流區(qū)的區(qū)域明顯變小,且被限制到在底坎的前部??埠笾吝M(jìn)水池前的流線較為平順,無回流區(qū)的存在,進(jìn)水池的進(jìn)水流態(tài)得到很好地調(diào)整。

        4.2.1倒T形底坎位置對流態(tài)改善影響

        底坎距進(jìn)水池的位置對底坎整流效果有重要的影響,方案2的底坎距離進(jìn)水池較近(L=5D),坎后水流旋滾的區(qū)域比較小,水體能量得不到充分的交換,影響進(jìn)水流態(tài)。方案4的底坎距離進(jìn)水池較遠(yuǎn)(L=10D),坎前的回流區(qū)被限制在較小的區(qū)域中,使得水流越過底坎前具有較大的能量,坎后的漩滾區(qū)變長,水流中的能量未被充分的交換就進(jìn)入進(jìn)水池內(nèi),影響進(jìn)水池內(nèi)流態(tài)。設(shè)置合理位置的倒T形底坎后(方案3,L=10D),前池兩側(cè)回流區(qū)被限制到坎前,由于回流區(qū)變小,主流不再向前池的一側(cè)偏斜。

        4.2.2[JP3]倒T形底坎上部寬度對流態(tài)改善影響

        研究表明,倒T形底坎的上部結(jié)構(gòu)具有分流作用,方案5中的底坎上部結(jié)構(gòu)過小(X=005B),分流作用不明顯(圖10),方案6中的底坎上部結(jié)構(gòu)過大(X=015B),使得水流經(jīng)過底坎時的過水?dāng)嗝孀冃。埠蟮匿鰸L變強(qiáng)(圖11),水力損失變大。當(dāng)上部結(jié)構(gòu)大小適中時(X=01B)即方案4,坎后漩滾能起到較好的分流和流態(tài)改善作用(圖8)。

        4.3倒T形底坎對站前行近流速影響

        圖14為方案1和方案3(優(yōu)化方案)的10個機(jī)組在11斷面上的行近流速分布比較。由圖可知,方案1機(jī)組前行近流速分布呈錐形,中間機(jī)組流速高,兩側(cè)機(jī)組流速低,兩側(cè)機(jī)組(1號、2號、3號、8號、9號和10號)前的行近流速為負(fù)值,前池兩側(cè)進(jìn)水流態(tài)較差。方案3為倒T形底坎措施整流優(yōu)化方案,其行近流速分布較方案1均勻,方案3中間機(jī)組行近流速分布更為均勻,流態(tài)改善效果明顯。

        4.4倒T形底坎整流效果分析

        綜合上述各研究方案,當(dāng)加入倒T形底坎后,底坎前的水流流速分布為中間大兩側(cè)小,水流流過倒T形底坎,在坎后形成漩滾,水流發(fā)生能量交換,同時受倒T形底坎上部結(jié)構(gòu)的分流作用,在前池兩側(cè)的水流的流速變大,使得機(jī)組前的水流流速變得更加均勻,泵組進(jìn)水池入流得到明顯改善(圖15)。

        5結(jié)論

        基于CFD技術(shù),研究了倒T形底坎的位置和其上部結(jié)構(gòu)的寬度及高度對前池流態(tài)的影響。

        (1)倒T形底坎能改善大擴(kuò)散角正向進(jìn)水前池內(nèi)水流流態(tài),減少回流區(qū)的范圍。

        (2)倒T形底坎對前池兩側(cè)機(jī)組行近流速有明顯的提高作用,有助于提高兩側(cè)機(jī)組的運(yùn)行效率,減少前池兩側(cè)的泥沙淤積。

        (3)倒T形底坎設(shè)置在前池中的位置和其上部結(jié)構(gòu)的尺寸對前池整流效果有明顯的影響。

        (4)本文推薦倒T形底坎設(shè)置在前池中距進(jìn)水池入口75D的位置,上部結(jié)構(gòu)高度為04H,寬度為01B。

        參考文獻(xiàn)(References):

        [1]劉超.水泵及水泵站[M].北京:中國水利水電出版社,2009.(LIU C.Pump and pump station[M].Beijing:China Water Power Press,2009.(in Chinese))

        [2]GASTON E F,MARCELA P,LARRY W.Numerical simulation of free surface flows on a fish bypass[J].Computer & Fluids,2009,38(5):9971002.

        [3]TANG X L,WANG W C,WANG F J,et al.Application of LBMSGS model to flows in a pumpingstation forebay[J].Journal of Hydrodynamics,2010,22(2):196206.

        [4]張賢明,吉慶豐.泵站前池流態(tài)的數(shù)值模擬[J].灌溉排水,2001,20(1):3538,42.(ZHANG X M,JI Q F.Numerical simulation of threedimensional turbulent flow in forebay of pumping station[J].Irrigation and Drainage,2001,20(1):3538,42.(in Chinese)) DOI:10.13522/j.cnki.ggps.2001.01.009.

        [5]周龍才.泵站前池隔墩整流的數(shù)值分析[J].長江科學(xué)院院報(bào),2010,27(2):3133.(ZHOU L C.Numerical analysis on improvement of flow conditions in forebay of pumping station by setting separation piers[J].Journal of Yangtze River Scientific Research Institute,2010,27(2):3133.(in Chinese))

        [6]成立,劉超,周濟(jì)人等.泵站前池底壩整流數(shù)值模擬研究[J].河海大學(xué)學(xué)報(bào),2001,29(3):4245.(CHENG L,LIU C,ZHOU J R,et al.Numerical simulation of sill flows in the forebay of pumping station[J].Journal of Hohai University,2001,29(3):4245.(in Chinese))

        [7]劉超,韓旭,周濟(jì)人等.泵站側(cè)向進(jìn)水引河段三維紊流數(shù)值模擬[J].排灌機(jī)械,2009,27(5):281286.(LIU C,HAN X,ZHOU J R,et al.Numerical simulation of turbulent flow in forebay with sideintake of pumping station[J].Drainage And Irrigation Machinery,2009,27(5):281286.(in Chinese))

        [8]劉新陽,高傳昌,石禮文等.泵站前池與進(jìn)水池整流數(shù)值模擬[J].排灌機(jī)械工程學(xué)報(bào),2010,28(3):242246.(LIU X Y,GAO C C,SHI L W,et al.Numerical simulation for fluid meliorating in both forebay and suction bay of pumping station[J].Journal Of Drainage And Irrigation Machinery Engineering,2010,28(3):242246.(in Chinese))

        [9]黃金偉,朱丕春,姚輝勇,等.引黃泵站前池進(jìn)水池整流措施[J].南水北調(diào)與水利科技,2014,12(2):146149,153.(HUANG J W,ZHU P C,YAO H Y,et al.Rectification measures of forybay in Yellow River Pumping Station[J].SouthtoNorth Water Transfers and Water Science & Technology,2014,12(2):146149,153.(in Chinese)) DOI:10.13476/j.cnki.nsbdqk.2014.02.034.

        [10][ZK(#]李秋瑋.交錯葉輪離心泵水力特性及泵站前池整流研究[D].武漢:武漢大學(xué),2011.(LI Q W.Research on the hydraulic characteristics of a centrifugal pump with staggered impeller and the improvement of flow field in a forebay[D].Wuhan:Wuhan University,2011.(in Chinese))

        [11]馮旭松.泵站前池底坎整流及坎后流動分析[J].江蘇水利,1998(1):3133,38.(FENG X S.Flow rectification and analysis of sill in the forebay of pump station[J].Jiangsu Hydraulics,1998(1):3133,38 (in Chinese))

        [12]成立,劉超,周濟(jì)人.水泵站底坎二維繞流湍流數(shù)值模擬[J].農(nóng)業(yè)機(jī)械學(xué)報(bào),2005,36(3):3739.(CHENG L,LIU C,ZHOU J R.Numerical simulation of turbulent flow around sill with RNG kε turbulent model[J].Transactions of the Chinese Society of Agricultural Machinery,2005,36(3):3739.(in Chinese))

        [13]羅燦,成立,劉超.泵站正向進(jìn)水前池底坎整流機(jī)理數(shù)值模擬[J].排灌機(jī)械工程學(xué)報(bào),2014,32(5):393398.(LUO C,CHENG L,LIU C.Numerical simulation of mechanism for sill rectifying flow in pumping station intake[J].Journal of Drainage and Irrigation Machinery Engineering,2014,32(5):393398.(in Chinese))

        [14]萬樂平.多泥沙河流泵站前池泥沙淤積過程數(shù)值模擬與流態(tài)改善[D].揚(yáng)州:揚(yáng)州大學(xué),2013.(WANG L P.Numerical simulation of flow field and improvement of the flow pattern in the forebay of a pumping station on the sedimentladen river[D].Yangzhou:Yangzhou University,2013.(in Chinese))

        [15]王鐵力.多泥沙河流泵站前池流態(tài)數(shù)值模擬及防淤措施研究[D].揚(yáng)州:揚(yáng)州大學(xué),2012.(WANG T L.Numerical simulation of flow field and research on the settlement to avoid sedimentation in the forebay of a pumping station on the sedimentladen river[D].Yangzhou:Yangzhou University,2012.(in Chinese))

        [16]劉升.多泥沙河流泵站前池泥沙淤積特性分析及防淤措施研究[D].揚(yáng)州:揚(yáng)州大學(xué),2011.(LIU S.Characteristic analysis of the sediment deposition and Research on the settlement to avoid sedimentation in the forebay of a pump station on the sedimentladen river[D].YYangzhou:angzhou University,2011.(in Chinese))

        [17]彭曉光.多泥沙河流泵站前池防淤積措施研究[D].揚(yáng)州:揚(yáng)州大學(xué),2010.(PENG X G.Research on the settlement to avoid sediment deposition in the forebay of a pumping station built on the sedimentladen river[D].Yangzhou:Yangzhou University,2010.(in Chinese))

        [18]張亞莉,宋世露,陳勇,等.泵站側(cè)向進(jìn)水前池整流措施數(shù)值模擬[J].中國農(nóng)村水利水電,2016(5):117120.(ZHANG Y L,SONG S L,CHEN Y,et al.Numerical simulation of rectification measures for sidedirection forebay in pump station[J].China Rural Water and Hydropower,2016(5):117120.(in Chinese))

        [19]高傳昌,劉新陽,石禮文,等.泵站前池與進(jìn)水池整流方案數(shù)值模擬[J].水力發(fā)電學(xué)報(bào),2011(2):5459.(GAO C C,LIU X Y,SHI L W,et al.Numerical simulation of flow pattern modification schemes for the forebay and suction sump of pumping station[J].Journal of Hydroelectric Engineering,2011(2):5459.(in Chinese))

        猜你喜歡
        前池流態(tài)數(shù)值模擬
        泵站非常規(guī)進(jìn)水前池的優(yōu)化設(shè)計(jì)
        側(cè)邊機(jī)組故障對泵站前池流態(tài)的影響
        水泵進(jìn)水前池及流道的三維數(shù)值模擬研究
        中小型水電站壓力前池安全運(yùn)行探討
        改進(jìn)邊界條件的非恒定流模型在城市河流橡膠壩流態(tài)模擬中的應(yīng)用
        跨音速飛行中機(jī)翼水汽凝結(jié)的數(shù)值模擬研究
        科技視界(2016年18期)2016-11-03 20:38:17
        姚橋煤礦采空區(qū)CO2防滅火的數(shù)值模擬分析
        雙螺桿膨脹機(jī)的流場數(shù)值模擬研究
        科技視界(2016年22期)2016-10-18 14:53:19
        一種基于液壓緩沖的減震管卡設(shè)計(jì)與性能分析
        科技視界(2016年20期)2016-09-29 11:08:27
        動態(tài)流態(tài)冰蓄冷系統(tǒng)在千級凈化廠房的應(yīng)用
        国产熟妇另类久久久久| 丰满少妇高潮惨叫久久久一 | 无码av天堂一区二区三区| 成年人黄视频大全| 国内少妇偷人精品视频免费| 亚洲最大中文字幕熟女| 国产剧情一区二区三区在线| 大量漂亮人妻被中出中文字幕| 一区二区三区午夜视频在线观看 | 一区二区三区无码高清视频| 日本一区二区视频在线| 激情一区二区三区视频| 日本在线播放不卡免费一区二区| 蜜桃a人妻精品一区二区三区| 国产精品久久一区性色a| 久久久久久中文字幕有精品| 中文乱码字慕人妻熟女人妻| 亚洲av无码专区亚洲av网站| 久久精品免费视频亚洲| 久久一区二区国产精品| 一区二区三区视频| 久久精品国产亚洲av成人| 天堂女人av一区二区| 国产高清a| 精品久久人人爽天天玩人人妻| 香蕉视频在线观看亚洲| 久久精品欧美日韩精品| 91免费在线| 国产精品无码精品久久久| 羞羞视频在线观看| 久久亚洲精品成人无码| 国产精品国产自产拍高清| 国产猛男猛女超爽免费视频| 97久久精品人人做人人爽| 日本三级吃奶头添泬| 亚洲精品国产精品乱码视色| 久青草影院在线观看国产| 伊人狼人影院在线视频| 日产精品高潮一区二区三区5月| 亚洲午夜精品a片久久www慈禧| 疯狂添女人下部视频免费|