楊永貴,沈智威,吳仁華,陳忠,蔡聰波,郭崗*
腦部化學(xué)交換飽和轉(zhuǎn)移成像研究
楊永貴1,沈智威2,吳仁華2,陳忠3,蔡聰波3,郭崗1*
化學(xué)交換飽和轉(zhuǎn)移(chem ical exchange saturation transfer, CEST)成像是在磁化傳遞及化學(xué)交換理論基礎(chǔ)上發(fā)展起來的一種磁共振成像新方法,其擴(kuò)展了磁共振分子影像新領(lǐng)域,但還處于研究階段。其以細(xì)胞內(nèi)物質(zhì)為內(nèi)源性對(duì)比劑,通過水信號(hào)間接檢測(cè)代謝物信息,進(jìn)行組織的酸堿度成像及其各種代謝物成像。本文主要探討MRI領(lǐng)域中與水相關(guān)的化學(xué)交換飽和轉(zhuǎn)移現(xiàn)象,闡述其原理、研究現(xiàn)狀及其在不同場(chǎng)強(qiáng)磁共振儀上腦部疾病的應(yīng)用。
化學(xué)交換飽和轉(zhuǎn)移;酰胺質(zhì)子轉(zhuǎn)移;酸堿度;腦腫瘤;腦梗死
Xiamen University, Department of Electronic Science, Fujian Province Key Laboratory of plasma and magnetic resonance, Xiamen 361005, China
Received 04 Jan 2016, Accepted 11 Mar 2016
ACKNOWLEDGMENTSThis work was part of Science and Technology Department of Xiamen Huim in project in 2014 (No. 3502Z20144052).
隨著計(jì)算機(jī)不斷發(fā)展,磁共振在科研與臨床方面的作用日漸重要,可反映解剖、功能及代謝方面的相關(guān)信息。在代謝方面,磁共振波譜技術(shù)可以探測(cè)某些代謝物濃度、甚至組織酸堿度,但因?yàn)槭軋?chǎng)強(qiáng)、硬件、分辨率等因素的影響,在敏感性及精準(zhǔn)顯示解剖結(jié)構(gòu)等方面存在一定的限制,從而制約了波譜研究的廣泛開展和推廣。
作為當(dāng)前世界范圍前沿新技術(shù),化學(xué)交換飽和轉(zhuǎn)移(chem ical exchange saturation transfer, CEST)磁共振成像技術(shù),從傳統(tǒng)的解剖成像擴(kuò)展到活體生化代謝和pH值成像,擴(kuò)展了磁共振分子影像新領(lǐng)域,為臨床疾病診斷治療甚至預(yù)防提供了一種全新的檢查手段。本文旨在闡述其原理、研究現(xiàn)狀及其在不同場(chǎng)強(qiáng)磁共振儀上腦部的應(yīng)用。
因?yàn)榛瘜W(xué)交換的存在,在特定的化學(xué)環(huán)境下,不同的質(zhì)子(-OH、-NH等)會(huì)從一種物質(zhì)的飽和狀態(tài)向另一種轉(zhuǎn)移,即飽和轉(zhuǎn)移效應(yīng)。目前,飽和轉(zhuǎn)移效應(yīng)作為一種補(bǔ)充的成像技術(shù)已廣泛應(yīng)用于臨床。本文主要探討MRI領(lǐng)域中與水相關(guān)的化學(xué)交換飽和轉(zhuǎn)移現(xiàn)象,即氫質(zhì)子飽和轉(zhuǎn)移,而對(duì)臨床MRI人體成像相關(guān)性不大的13C、19F、31P的化學(xué)交換飽和轉(zhuǎn)移不做討論。
化學(xué)交換飽和轉(zhuǎn)移成像是在磁化傳遞及化學(xué)交換理論基礎(chǔ)上發(fā)展起來的一種磁共振成像新方法,其原理是利用特定的偏共振飽和脈沖,對(duì)外源性或內(nèi)源性的特定物質(zhì)進(jìn)行充分的預(yù)飽和,這種飽和通過化學(xué)交換,進(jìn)一步影響自由水的信號(hào)強(qiáng)度,因此,通過檢測(cè)水的信號(hào),便可間接反映這種物質(zhì)的信息及化學(xué)交換的組織環(huán)境。由于CEST成像使用水信號(hào)間接檢測(cè)代謝物信息,因此,信號(hào)得到明顯的放大,可以探測(cè)的代謝物濃度達(dá)到微摩爾,甚至納摩爾級(jí)別。以細(xì)胞內(nèi)物質(zhì)為內(nèi)源性對(duì)比劑,進(jìn)行組織的酸堿度成像及其各種代謝物成像,具有廣泛的應(yīng)用前景[1-3]。
眾所周知,蛋白質(zhì)是生命的物質(zhì)基礎(chǔ),它與各種形式的生命活動(dòng)密切相關(guān)。機(jī)體的每一個(gè)細(xì)胞及所有的重要組成部分都有蛋白質(zhì)的參與,其占體重的比例達(dá)16%~20%。蛋白質(zhì)由肽鍵將氨基酸連接而成,而酰胺質(zhì)子正是肽鍵的組成部分之一,因此,其分布范圍非常廣泛。酰胺質(zhì)子轉(zhuǎn)移(am ide proton transfer, APT)成像[3-9]是一種基于CEST、能無創(chuàng)性地檢測(cè)內(nèi)源性的、位于細(xì)胞質(zhì)內(nèi)的游離蛋白質(zhì)及多肽分子的影像新技術(shù)。APT成像產(chǎn)生化學(xué)交換飽和轉(zhuǎn)移的物質(zhì)為細(xì)胞內(nèi)蛋白質(zhì)和/或多肽的酰胺質(zhì)子。酰胺質(zhì)子的化學(xué)位移為(8.3±0.5) ppm,即在水峰左邊3.5 ppm的位置[10]。釆用CEST技術(shù),用飽和脈沖激發(fā)可交換的酰胺質(zhì)子,被飽和了的酰胺質(zhì)子與未飽和的水中氫質(zhì)子進(jìn)行交換,使水中氫質(zhì)子的信號(hào)強(qiáng)度發(fā)生變化。但酰胺質(zhì)子的共振頻率在偏離水3.5 ppm處,活體檢測(cè)APT時(shí)難免帶來水的直接飽和效應(yīng)(w ater saturation)和傳統(tǒng)的磁化傳遞(magnetization transfer, M T)效應(yīng)。當(dāng)采用磁化轉(zhuǎn)移率來定量評(píng)價(jià)時(shí)必須分離出APT的效果:
其中,[water proton]為水質(zhì)子濃度,與含水量有關(guān)。[exchangeable proton]為CEST氨基質(zhì)子濃度。tsat為飽和脈沖飽和時(shí)間,T1w為縱向弛豫時(shí)間。一般對(duì)于水溶液里的氫交換有式(2)說明了氨基類化合物的化學(xué)交換率與pH值之間的關(guān)系。
疾病早期細(xì)胞內(nèi)外酸堿度的變化越來越受到人們的重視。酸堿度平衡是維持機(jī)體內(nèi)環(huán)境穩(wěn)態(tài)的重要組成部分之一。在正常情況下,機(jī)體各組織酸堿度處于一種動(dòng)態(tài)平衡過程,只在很小的范圍內(nèi)波動(dòng)。但在病理?xiàng)l件下,尤其是腦腫瘤酸堿度可能存在異常變動(dòng),因此可用它反映組織的生理、病理變化。目前尚無一種成熟的方法可實(shí)現(xiàn)無創(chuàng)地檢測(cè)活體酸堿度,而CEST成像可以實(shí)現(xiàn)這一目的,用于早期診斷和評(píng)估腦部疾病。且腫瘤中含有豐富的游離蛋白質(zhì)或多肽,早期診斷和綜合評(píng)估腫瘤的范圍及其與周圍解剖結(jié)構(gòu)的關(guān)系對(duì)于腫瘤的預(yù)后及治療有重要意義。
化學(xué)交換飽和轉(zhuǎn)移成像的概念來源于磁化傳遞成像。2000年,Ward和Balaba等人[1-2, 11]在研究小分子溶液的磁化傳遞現(xiàn)象時(shí)觀察到靠近水共振頻率Z譜不對(duì)稱性的現(xiàn)象,將之命名為化學(xué)交換飽和轉(zhuǎn)移。
目前,對(duì)CEST的研究主要集中在兩方面,一種是對(duì)化學(xué)交換的組織環(huán)境進(jìn)行成像,包括pH、溫度等;一種是對(duì)化學(xué)交換物質(zhì)進(jìn)行成像,包括蛋白質(zhì)、多肽、多糖及脂質(zhì)等。對(duì)細(xì)胞內(nèi)外pH的準(zhǔn)確無創(chuàng)測(cè)量及精確的空間分辨率,使CEST在pH成像方面具有特有的優(yōu)勢(shì)。研究表明,該化學(xué)交換速率與酸堿度之間存在明確的對(duì)應(yīng)關(guān)系[12]。Zhou等[4-6, 10]利用CEST成像原理對(duì)體內(nèi)微量的蛋白質(zhì)、氨基酸成像,研究了高場(chǎng)下(4.7 T)小鼠腦卒中的APT對(duì)比及絕對(duì)pH效果圖,還進(jìn)行了大鼠的腦腫瘤成像。Sun等[12]于2011年進(jìn)行腦梗死的磁共振pH成像,并提出了利用其測(cè)量缺血半暗帶的可能,不斷地優(yōu)化完善磁共振pH成像序列,并創(chuàng)立了適合臨床使用的pH成像序列,實(shí)現(xiàn)了從定性測(cè)量到粗略定量測(cè)量,從單層面測(cè)量到多層面測(cè)量,從實(shí)驗(yàn)室到臨床的初步轉(zhuǎn)化[13-15]。在組織代謝測(cè)定方面,有學(xué)者進(jìn)行了乳酸[16]、葡萄糖[17-18]的CEST研究。
同樣是利用CEST技術(shù),對(duì)于細(xì)胞外的pH成像需要注入成像對(duì)比劑,這種對(duì)比劑可以是機(jī)體內(nèi)源性物質(zhì)(如糖類、氨基酸等),也可以是外源性對(duì)比劑。在標(biāo)記細(xì)胞成像方面,與對(duì)標(biāo)記細(xì)胞的總體成像的Gd類、Fe類對(duì)比劑不同的是,CEST類對(duì)比劑可選擇不同的共振頻率對(duì)不同細(xì)胞進(jìn)行CEST成像,進(jìn)而使CEST技術(shù)同時(shí)標(biāo)記兩種或多種細(xì)胞成像成為可能[19]。Aime等[20]認(rèn)為paraCEST類對(duì)比劑可以通過胞吞作用進(jìn)入細(xì)胞,并使用[Yb(dotamGly)]和[Eu(dotamGly)]兩種paraCEST對(duì)比劑在培養(yǎng)胞的實(shí)驗(yàn)證實(shí)了paraCEST有標(biāo)記細(xì)胞作用。
目前,CEST被應(yīng)用于諸多領(lǐng)域的研究中,除了pH成像[4, 21]、代謝物檢測(cè)[22]、蛋白質(zhì)成像[5, 23]、氨基酸類檢測(cè)[24]、葡萄糖類檢測(cè)[25-26]、粘多糖[19, 27]、細(xì)胞標(biāo)記[28]、酶的活力檢測(cè)[29]及CEST基因報(bào)告[30],還用于全新實(shí)驗(yàn)方法的開發(fā)和利用,如使用共振方法的WALTZ序列[31]、分子間二量子相干[32]、自旋鎖定(spin-lock ing)[33]及頻率標(biāo)注交換轉(zhuǎn)移(frequency-labeled exchange transfer)[34]等。
CEST作為當(dāng)前世界范圍前沿新技術(shù),還大多處于研究階段,臨床的研究剛剛起步,并且局限于3.0 T。之所以這樣,是因?yàn)閷?shí)現(xiàn)APT成像需要兩個(gè)基本條件[12],即△ω≥K和R 1≤K,其中△ω為酰胺質(zhì)子與自由水質(zhì)子的化學(xué)位移差,K為化學(xué)交換速率,R1為水質(zhì)子的縱向弛豫速率。酰胺質(zhì)子的共振峰位于8.3 ppm處,相對(duì)于水峰而言,△ω為3.5 ppm,則3.0 T場(chǎng)強(qiáng)下,△ω為448 Hz,且K值范圍為10~300 Hz,故3.0 T場(chǎng)強(qiáng)的磁共振上進(jìn)行APT成像是符合條件的,且可以進(jìn)行定量分析組織的pH值。而目前臨床應(yīng)用的磁共振儀大多以1.5 T場(chǎng)強(qiáng)為主,在1.5 T場(chǎng)強(qiáng)的磁場(chǎng)下,△ω=224 Hz,故只有部分滿足△ω≥K這個(gè)條件,故在飽和的過程中將直接影響到水峰,且信噪比相對(duì)較低。2008年,Zhou等[23]在3.0 T MR儀進(jìn)行了腦腫瘤的APT成像,并指出APT成像可以很好地區(qū)分腫瘤和水腫的范圍。而常規(guī)T1W I、T2W I以及DW I等方法無法得到這樣的效果,且釓劑增強(qiáng)的T1W I只有部分血腦屏障被破壞的腫瘤區(qū)域才能看見,但對(duì)于惡性膠質(zhì)瘤,10%的膠質(zhì)母細(xì)胞瘤和20%~30%的間變型星形細(xì)胞瘤在釓劑增強(qiáng)掃描時(shí)無明顯強(qiáng)化,無法區(qū)分腫瘤浸潤(rùn)范圍及其邊界。并且釓劑增強(qiáng)可能引發(fā)過敏、腎功能損害等并發(fā)癥。Sun等[12, 14, 35]使用APT成像的方法在3.0 T MR設(shè)備上得到了pH值不同的組織成像,同時(shí)指出APT成像具有在急性腦梗死時(shí)對(duì)缺血腦組織的判斷和指導(dǎo)治療的診斷價(jià)值。另有研究報(bào)道CEST在阿爾茨海默氏病[36]的研究也有一定程度上的應(yīng)用,可以顯示因神經(jīng)元脫失和細(xì)胞內(nèi)異常蛋白增加所致的信號(hào)改變,故其有望為阿爾茨海默氏病臨床診斷、病情監(jiān)測(cè)及病理生理研究等方面提供重要的客觀評(píng)價(jià)依據(jù)。
近年來,吳仁華等科研團(tuán)隊(duì)在1.5 T MR設(shè)備上進(jìn)行了CEST相關(guān)的研究,指出現(xiàn)有的臨床1.5 T磁共振掃描儀上的磁化傳遞序列能通過序列參數(shù)的優(yōu)化和偏置頻率的選取來獲得能反映不同pH值的磁化傳遞成像,為pH值敏感的磁化傳遞成像在臨床上的應(yīng)用提供了重要的實(shí)驗(yàn)基礎(chǔ)[37]。
目前CEST臨床應(yīng)用研究存在的問題是準(zhǔn)確定量pH需要涉及到許多參數(shù)的優(yōu)化定量,其中包括預(yù)飽和脈沖能量、時(shí)間、波形、個(gè)數(shù)等都有很大關(guān)系。還有在體內(nèi)的CEST效應(yīng)在高分子磁化傳遞競(jìng)爭(zhēng)[38]、直接的水飽和度(溢出效應(yīng))[15, 39]和隨之而來的飽和的交換或偶極耦合池(NOE效應(yīng))[40-41]。此外,這些干擾的影響強(qiáng)烈地依賴于磁場(chǎng)強(qiáng)度(B0)、射頻輻射振幅(B1)和其他實(shí)驗(yàn)參數(shù)[42]。且CEST在腦部疾病的應(yīng)用另有一些影響因素,包括組織的游離蛋白及多肽的含量(最主要)、水含量、pH值及溫度,還有頭部運(yùn)動(dòng)導(dǎo)致的CEST圖像上腦表面及腦室的偽影及CEST效應(yīng)很小導(dǎo)致的圖像空間分辨率極低等。但隨著研究工作的不斷開展,相信CEST的應(yīng)用將日趨成熟。
腦部CEST技術(shù)的研究為準(zhǔn)確無創(chuàng)傷性地檢測(cè)腦部疾病早期代謝和pH值變化,探討腦部疾病早期診斷和療效監(jiān)測(cè)的分子影像學(xué)新技術(shù)和新方法,并將具有廣泛的實(shí)用性和較高的應(yīng)用價(jià)值的研究成果應(yīng)用到臨床,為腦科學(xué)研究和臨床工作提供分子學(xué)影像新工具。
[References]
[1]Ward KM, Aletras AH, Balaban RS. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Reson, 2000, 143(1): 79-87.
[2]Teng GJ, Cui Y. Research progress in m olecular m agnetic resonance imaging. Chin J M agn Reson Im aging, 2014, 5(S1): 31-36.
滕皋軍, 崔瑩. 磁共振分子影像學(xué)研究進(jìn)展. 磁共振成像, 2014, 5(S1): 31-36.
[3]Zijl PCMV, Yadav NN. Chem ical exchange saturation transfer (CEST): W hat is in a name and what isn't?. M agn Reson M ed, 2011, 65(4): 927-948.
[4]Zhou J, Payen JF, W ilson DA, et al. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat Med, 2003, 9(8): 1085-1090.
[5]Zhou J, Lal B, W ilson DA, et al. Am ide proton transfer (APT) contrast for imaging of brain tumors. M agn Reson M ed, 2003, 50(6): 1120-1126.
[6]Sun PZ, Zhou J, Sun W, et al. Detection of the ischem ic penumbra using pH-weighted MRI. J Cereb Blood Flow Metab, 2006, 27(6): 1129-1136.
[7]Sun PZ, W ang E, Cheung JS. Imaging acute ischem ic tissue acidosis w ith pH-sensitive endogenous amide proton transfer (APT) MRI-Correction of tissue relaxation and concomitant RF irradiation effects toward mapping quantitative cerebral tissue pH. Neuroimage, 2012, 60(1): 1-6.
[8]Jia G, Abaza R, W illiams JD, et al. Am ide proton transfer MR imaging of prostate cancer: A preliminary study. J Magn Reson Imaging, 2011, 33(3): 647-654.
[9]Wang S, Jarso S, Van Zijl PC, et al. Role of amide proton transfer (APT)-MRI of endogenous proteins and peptides in brain tum or imaging. Functional B rain Tumo r Im ag ing. Springer, 2014: 171-181.
[10]Mori S, Eleff SM, Pilatus U, et al. Proton NMR spectroscopy of solvent-saturable resonances: A new approach to study pH effects in Situ. Magn Reson Med, 1998, 40(1): 36-42.
[11]W o lff SD, Balaban RS. NMR im aging of lab ile proton exchange. J M agn Reson, 1990, 86(1): 164-169.
[12]Sun PZ, Wang E, Cheung JS, et al. Simulation and optimization of pulsed radio frequency (RF) irradiation scheme for chemical exchange saturation transfer(CEST) MRI-demonstration of pH-weighted pulsed-am ide proton CEST MRI in an animal model of acute cerebral ischem ia. M agn Reson M ed, 2011, 66(4): 1042-1048.
[13]Sun PZ, Zhou J, Huang J, et al. Simp lified quantitative description of am ide proton transfer (APT) imaging during acute ischemia. Magn Reson Med, 2007, 57(2): 405-410.
[14]Sun PZ, M urata Y, Lu J, et al. Relaxation-com pensated fast multislice am ide proton transfer (APT) im aging of acu te ischemic stroke. Magn Reson Med, 2008, 59(5): 1175-1182.
[15]Sun PZ, Sorensen AG. Imaging pH using the chemical exchange saturation transfer (CEST)MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH. Magn Reson Med, 2008, 60(2): 390-397.
[16]Aime S, Delli CD, Fedeli F, et al. A paramagnetic MRI-CEST agent responsive to lactate concentration. J Am Chem Soc, 2002, 124(32): 9364-9365.
[17]Zhang S, W inter P, W u K, et al. A novel europium (III)-based MRI contrast agent. J Am Chem Soc, 2001, 123(7): 1517-1518.
[18]Ren J, Trokow ski R, Zhang S, et al. Im aging the tissue distribution of glucose in livers using a paracest sensor. Magn Reson Med, 2008, 60(5): 1047-1055.
[19]Gilad AA, Van Laarhoven HW, M cmahon MT, et al. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles. Magn Reson M ed, 2009, 61(4): 970-974.
[20]Aime S, Barge A, Delli Castelli D, et al. Paramagnetic Lanthanide(III) com plexes as pH-sensitive chem ical exchange saturation transfer (CEST) contrast agents for MRI applications. Magn Reson Med, 2002, 47(4): 639-648.
[21]W ard K, Balaban R. Determ ination of pH using water protons and chemical exchange dependent saturation transfer (CEST). Magn Reson Med, 2000, 44(5): 799-802.
[22]Dagher AP, A letras A, Choyke P, et al. Imaging of urea using chemical exchange-dependent saturation transfer at 1.5 T. J M agn Reson Imaging, 2000, 12(5): 745-748.
[23]Zhou J, Blakeley JO, Hua J, et al. Practical data acquisition method for human brain tumor am ide proton transfer (APT) imaging. M agn Reson M ed, 2008, 60(4): 842-849.
[24]Cai K, Haris M, Singh A, et al. Magnetic resonance imaging of glutamate. Nat Med, 2012, 18(2): 302-306.
[25]Zhang S, Trokowski R, Sherry AD. A paramagnetic CEST agent for imaging glucose by MRI. J Am Chem Soc, 2003, 125(50): 15288-15289.
[26]Van Zijl PC, Jones CK, Ren J, et al. MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST). Proc Natl Acad Sci U S A, 2007, 104(11): 4359-4364.
[27]Ling W, Regatte RR, N avon G, et al. Assessm en t of g lycosam inoglycan concentration in vivo by chem ical exchange-dependent saturation transfer (gagCEST). Proc Natl Acad Sci U S A, 2008, 105(7): 2266-2270.
[28]Aime S, Barge A, Cabella C, et al. Targeting cells w ith MR imaging probes based on paramagnetic Gd (III) chelates. Current pharmaceutical biotechnology, 2004, 5(6): 509-518.
[29]Yoo B, Pagel MD. A PARACEST MRI contrast agent to detect enzyme activity. J Am Chem Soc, 2006, 128(43): 14032-14033.
[30]Gilad AA, M cmahon MT, Walczak P, et al. Artificial reporter gene providing MRI contrast based on proton exchange. Nature biotechnology, 2007, 25(2): 217-219.
[31]Vinogradov E, Zhang S, Lubag A, et al. On-resonance low B1 pulses for imaging of the effects of paracest agents. J Magn Reson, 2005, 176(1): 54-63.
[32]Zhang S, Zhu X, Chen Z, et al. Improvement in the contrast of CEST MRI via intermolecular double quantum coherences. Phys Med Biol, 2008, 53(14): 287-296.
[33]Jin T, Autio J, Obata T, et al. Spin-locking versus chem ical exchange saturation transfer MRI for investigating chem ical exchange process between water and labile metabolite protons. Magn Reson Med, 2011, 65(5): 1448-1460.
[34]Friedman JI, M cmahon MT, Stivers JT, et al. Indirect detection of labile solute proton spectra via the water signal using frequency-labeled exchange (FLEX) transfer. J Am Chem Soc, 2010, 132(6): 1813-1815.
[35]Sun PZ, Benner T, Kumar A, et al. Investigation of optimizing and translating pH-sensitive pulsed-chem ical exchange saturation transfer (CEST) imaging to a 3T clinical scanner. Magn Reson Med, 2008, 60(4): 834-841.
[36]Haris M, Singh A, Cai K, et al. M ICEST: a potential tool for non-invasive detection of molecular changes in A lzheimer’s disease. J Neurosci Methods, 2013, 212(1): 87-93.
[37]Wei MB, Shen ZW, Xiao G, et al. Study of magnetic resonance imaging at 1.5 Tesla based on pH-sensitive magnetization transfer technology. Chin J M agn Reson Imaging, 2012, 3(1): 40-43.韋茂彬, 沈智威, 肖剛, 等. 基于pH值敏感的磁化傳遞技術(shù)在1.5 T磁共振成像上的研究. 磁共振成像, 2012, 3(1): 40-43.
[38]Henkelman RM, Stanisz GJ, Graham SJ. Magnetization transfer in MRI: a review. NMR Biomed, 2001, 14(2): 57-64.
[39]Mulkern RV, William s ML. The general solution to the Bloch equation w ith constant rf and relaxation terms: application to saturation and slice selection. M ed Phys, 1993, 20(1): 5-13.
[40]Jin T, Wang P, Zong X, et al. MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear Overhauser effect at 9.4 T. Magn Reson Med, 2013, 69(3): 760-770.
[41]Liu D, Zhou J, Xue R, et al. Quantitative characterization of nuclear overhauser enhancem ent and am ide proton transfer effects in the human brain at 7 tesla. Magn Reson Med, 2013, 70(4): 1070-1081.
[42]Liu G, Song X, Chan KW, et al. Nuts and bolts of chemical exchange saturation transfer MRI. NMR Biomed, 2013, 26(7): 810-828.
資訊 Information
如何在《磁共振成像》雜志快速發(fā)表優(yōu)秀稿件
《磁共振成像》雜志自2015年1月由雙月刊變更為月刊以來,增加了刊發(fā)論文數(shù)量、縮短了刊發(fā)周期,發(fā)表了大量有很高學(xué)術(shù)價(jià)值和臨床應(yīng)用價(jià)值的高水平論文。
在戴建平主編領(lǐng)導(dǎo)和廣大編委、審稿專家和作者的共同努力下,2015年《磁共振成像》雜志被評(píng)為中國(guó)科學(xué)引文數(shù)據(jù)庫(CSCD)2015-2016年度來源期刊、中國(guó)科技核心期刊、中國(guó)科技論文統(tǒng)計(jì)源期刊、RCCSE中國(guó)核心學(xué)術(shù)期刊(A)(中國(guó)科學(xué)評(píng)價(jià)研究中心頒發(fā)),并獲得“2015年度中國(guó)醫(yī)藥衛(wèi)生媒體最佳實(shí)踐創(chuàng)新獎(jiǎng)”。中國(guó)科學(xué)院文獻(xiàn)情報(bào)中心2015年9月9日發(fā)布的“2015卷中國(guó)科學(xué)計(jì)量指標(biāo):期刊引證報(bào)告”20種特種醫(yī)學(xué)期刊中,《磁共振成像》雜志影響因子0.9684排名第一,基金論文比0.575居特種醫(yī)學(xué)第一位。 2015年10月21日中國(guó)科技信息研究所發(fā)布的“2015年版中國(guó)科技核心期刊引證報(bào)告(核心版)”顯示,《磁共振成像》雜志核心期刊影響因子0.828,在臨床診斷類期刊中位列前茅;影響因子在放射影像類期刊排名第五,基金論文比排名第一,海外論文比排名第一。
自創(chuàng)刊以來,《磁共振成像》雜志在海外顧問和編委的支持下,海外論文比在醫(yī)學(xué)影像類期刊中排名一直是第一名,被世界六大檢索系統(tǒng)之一——美國(guó)《化學(xué)文摘》(CA)以及美國(guó)《劍橋科學(xué)文摘(自然科學(xué))》(CSA)、美國(guó)《烏利希國(guó)際期刊指南》、波蘭《哥白尼索引》(IC)等數(shù)據(jù)庫持續(xù)收錄,相對(duì)來說具有較高國(guó)際影響力。
有的作者因?yàn)椴涣私狻洞殴舱癯上瘛冯s志的稿件處理流程和原則,因?yàn)樽陨碓蜓舆t了發(fā)表時(shí)間。為進(jìn)一步提高我刊學(xué)術(shù)質(zhì)量,吸收優(yōu)秀、高質(zhì)量的稿件和縮短優(yōu)質(zhì)稿件的刊發(fā)周期,在此向大家介紹一下延遲發(fā)表的常見問題和編輯部?jī)?yōu)先處理稿件原則,簡(jiǎn)稱“雙12注意”。
一、延遲發(fā)表的常見問題
1、稿件投稿未在官網(wǎng)(www.c jm ri.cn)登錄作者投稿系統(tǒng)注冊(cè)、投稿。通過郵箱投稿一律不予處理,必須在官網(wǎng)作者投稿系統(tǒng)提交。該投稿系統(tǒng)是惟一的,謹(jǐn)防假冒。
2、投稿時(shí)提交文件不全。投稿時(shí)必須提交:A、稿件Word文件;B、電子版投稿介紹信(單位介紹信)。另外,文內(nèi)有圖片的必須提交.tif格式的圖片文件。除A、B兩項(xiàng)外,其他文件必須用壓縮軟件壓縮成一個(gè)文件包(zip或rar格式的壓縮文件)以“原稿相關(guān)附件”上傳。投稿時(shí)第一作者和通訊作者的通訊信息必須齊全。
3、介紹信不符合要求。介紹信必須注明投稿期刊名稱、投稿題目、全部作者、加蓋單位相關(guān)部門公章、介紹信開具時(shí)間,并且證明此稿不涉及保密、非一稿多投、署名無爭(zhēng)議。作者要妥善保存介紹信原件,稿件錄用后需要郵寄至編輯部。
4、稿件格式不符合要求。
(1)作者信息不全。稿件Word文件中正文前必須附第一作者簡(jiǎn)介和通訊作者郵箱、手機(jī)號(hào),第一作者簡(jiǎn)介至少應(yīng)包括:姓名、出生年、性別、學(xué)歷(學(xué)位)、職稱、職務(wù)、研究方向、郵箱、手機(jī)號(hào)。
(2)圖片不符合要求。Word稿件中如果有圖片,請(qǐng)另外附tif格式的圖片文件,圖片的文件名命名為圖號(hào)。圖片的寬度不應(yīng)小于5 cm,分辨率不可低于300 dpi。Tif格式的圖片上不得有圖號(hào),如有箭頭請(qǐng)不要與原圖合并圖層。圖片上不得有患者姓名,患者面部主要特征須做遮擋處理。影像學(xué)圖片盡量附病理圖。圖片文件和除稿件word文件、介紹信jpg文件以外的其他文件必須用壓縮軟件壓縮成一個(gè)文件包(zip或rar格式的壓縮文件)。
(3)圖注不符合要求。圖注要求中英文對(duì)應(yīng),提交稿件時(shí)不要忘記英文圖注。圖注中除影像學(xué)描述外,應(yīng)注明患者基本情況,如性別、年齡,患病時(shí)間等。
(4)表格不符合要求。表格的標(biāo)題需要中英文對(duì)應(yīng),表格內(nèi)容以及注解需要用英文。表格形式為三線表。
(5)參考文獻(xiàn)格式不符合要求。A. 中文參考文獻(xiàn)需要中英文對(duì)應(yīng)。B. 期刊論文參考文獻(xiàn)作者姓名要與Medline數(shù)據(jù)庫中一致,多于3名的列出前3名,后加“, et al.”。C. 期刊論文參考文獻(xiàn)年、卷、期、起止頁、必須寫全,不得漏掉任何一項(xiàng)。D. 參考文獻(xiàn)中期刊名稱縮寫要與Medline數(shù)據(jù)庫中一致。
5、材料與方法內(nèi)容不全。
(1)病例資料必須寫明來自哪家醫(yī)院。
(2)涉及人的前瞻性研究必須寫明該研究已征得患者/試驗(yàn)者知情同意并簽署知情同意書,涉及倫理問題的要寫明是否經(jīng)該單位倫理委員會(huì)批準(zhǔn)并注明批準(zhǔn)文號(hào)。涉及動(dòng)物的實(shí)驗(yàn)研究必須寫明是否經(jīng)該單位倫理委員會(huì)批準(zhǔn)并注明批準(zhǔn)文號(hào)。
(3)儀器設(shè)備、藥品、實(shí)驗(yàn)動(dòng)物要寫明型號(hào)并注明生產(chǎn)廠家和國(guó)別。
(4)對(duì)照性研究必須要寫明入組標(biāo)準(zhǔn)。
(5)必須寫清楚統(tǒng)計(jì)學(xué)軟件名稱、版本以及統(tǒng)計(jì)學(xué)方法和閥值。
6、涉嫌抄襲。編輯部將通過萬方數(shù)據(jù)和CNKI數(shù)據(jù)庫對(duì)投稿進(jìn)行學(xué)術(shù)不端檢測(cè)。文字復(fù)制比不得超過15%。
7、基金項(xiàng)目著錄不準(zhǔn)確?;痦?xiàng)目論文須在正文前列出基金項(xiàng)目類別(如國(guó)家自然科學(xué)基金面上項(xiàng)目)和編號(hào)。投稿時(shí)提交基金項(xiàng)目批文電子版(與稿件的其他附件壓縮在一個(gè)壓縮包內(nèi)提交)。基金項(xiàng)目需要中英文對(duì)應(yīng)。
8、論文內(nèi)容超范圍。只有與磁共振成像相關(guān)的論文才可投稿。投稿作者所在科室可以是磁共振科室,也可以是神經(jīng)內(nèi)科、心內(nèi)科、骨科、神經(jīng)外科、消化科、內(nèi)分泌科、婦產(chǎn)科、兒科、中醫(yī)科等臨床科室,還可以是科研院所、大學(xué)的相關(guān)部門。
《磁共振成像》雜志歡迎磁共振相關(guān)物理、化學(xué)以及計(jì)算機(jī)圖像處理研究的稿件,歡迎功能和分子磁共振相關(guān)的基礎(chǔ)研究稿件。
與磁共振成像無關(guān)的稿件不予處理。
9、未及時(shí)繳納審稿費(fèi)。作者提交稿件后將同時(shí)獲得稿號(hào),作者必須及時(shí)繳納審稿費(fèi)(個(gè)案報(bào)道類稿件30元/篇,其他稿件50元/篇),否則編輯部不予處理。作者繳費(fèi)后須及時(shí)將繳費(fèi)的電子回單發(fā)郵件至editor@cjm ri.cn。
10、未按照編輯的意見及時(shí)修回。作者投稿后應(yīng)及時(shí)查閱郵箱或登錄投稿系統(tǒng)查看稿件狀態(tài),及時(shí)按照編輯部要求補(bǔ)充、修改稿件。編輯部對(duì)稿件的任何通知均通過專用電子郵件(郵箱后綴為@cjm ri.cn)發(fā)送。
11、稿件被錄用后未及時(shí)交納版面費(fèi)或未及時(shí)快遞符合要求的單位介紹信和版權(quán)轉(zhuǎn)讓合同。
12、稿件被錄用后未及時(shí)校對(duì)并返回電子版清樣(pdf文件)。
二、編輯部?jī)?yōu)先處理的原則。以下稿件將得到優(yōu)先處理:
1、省部級(jí)以上基金項(xiàng)目稿件優(yōu)先處理,2個(gè)月內(nèi)決定錄用與否。錄用的稿件一般在4個(gè)月內(nèi)發(fā)表。需提供基金項(xiàng)目批準(zhǔn)文件。
2、近2年在《磁共振成像》雜志發(fā)表過論文并且該論文被引用2次以上的第一作者再次以第一作者投稿。需提供引用參考文獻(xiàn)及鏈接。
3、近2年在其他雜志發(fā)表論文時(shí)引用《磁共振成像》雜志已發(fā)表論文2次以上的第一作者所投稿件。需提供引用參考文獻(xiàn)及鏈接。
4、《磁共振成像》雜志編委或?qū)徃鍖<覟榈谝换蛲ㄓ嵶髡叩母寮?/p>
5、全英文稿(附中文題目、摘 要、作者、作者單位、基金項(xiàng)目)優(yōu)先處理。
6、近2年連續(xù)2年訂閱《磁共振成像》雜志的讀者作為第一作者投稿。需提供訂購憑條掃描件電子版。
7、符合《磁共振成像》雜志年度選題的稿件。年度選題可在官網(wǎng)查閱。
8、近2年連續(xù)向《磁共振成像》雜志有效投稿4篇以上未被錄用,再次以第一作者投稿的稿件。需提供原投稿稿號(hào)。
9、近2年注冊(cè)參加過《磁共振成像》雜志社主辦的學(xué)術(shù)會(huì)議、學(xué)習(xí)班的人員以第一作者投稿的稿件。需提供會(huì)務(wù)發(fā)票掃描件的電子版。
10、編輯部約稿稿件優(yōu)先處理。
11、具有科學(xué)性、前沿性、實(shí)用性、新思想、新觀點(diǎn),并對(duì)磁共振成像領(lǐng)域具有較高參考價(jià)值和指導(dǎo)意義的臨床研究、基礎(chǔ)研究、綜述類稿件,并附2位(或以上)《磁共振成像》雜志編委、審稿專家推薦意見。
12、《磁共振成像》雜志主編、副主編、編輯部主任推薦的稿件。
Research of chem ical exchange saturation transfer in brain
YANG Yong-gui1, SHEN Zhi-wei2, WU Ren-hua2, CHEN Zhong3, CAI Cong-bo3, GUO Gang1*1Department of medical imaging, The Second Hospital of Xiamen, Xiamen 361021, China
2Departmentof Radiology, The Second A ffiliated Hospital of Shantou University Medical College, Shantou 515041, China
3Physical and mechanical and Electrical Engineering College of Xiamen University,
Chemical exchange saturation transfer (CEST) imaging is a new method for magnetic resonance imaging theory of exchange in the magnetization transfer and chem ical, the expansion of the new field of molecular magnetic resonance imaging, but it’s still in the research stage. The intracellular substances as an endogenous contrast agent, through the indirect detection of metabolite water signal information for tissue pH imaging and imaging of various metabolites. This paper mainly discusses the chem ical and water exchange in the field of MRI saturation transfer phenomenon, expounds the principle, research status and the application in brain diseases used the different field strength clinical MRI scanner.
Chem ical exchange saturation transfer; Am ide proton transfer; pH value; Brain tumor; Stroke
2014年廈門市科技局科技惠民計(jì)劃項(xiàng)目(編號(hào):3502Z20144052)
1. 廈門市第二醫(yī)院醫(yī)學(xué)影像科,廈門361021
2. 汕頭大學(xué)醫(yī)學(xué)院第二附屬醫(yī)院放射科,汕頭 515041
3. 廈門大學(xué)物理與機(jī)電工程學(xué)院,廈門大學(xué)電子科學(xué)系,福建省等離子體與磁共振研究重點(diǎn)實(shí)驗(yàn)室,廈門361005
郭崗,E-mail: guogangxm@163.com
2016-01-04
接受日期:2016-03-11
R445.2
A
10.12015/issn.1674-8034.2016.04.002
楊永貴, 沈智威, 吳仁華, 等. 腦部化學(xué)交換飽和轉(zhuǎn)移成像研究. 磁共振成像, 2016, 7(4): 249–253.
*Correspondence to: Guo G, E-mail: guogangxm@163.com