        Experimental study on capacity of bubble to carry water

        2013-09-21 07:52:34WANGYongJINLianganCHIWeiQUYi
        實(shí)驗(yàn)流體力學(xué) 2013年2期
        關(guān)鍵詞:雙液液流氣泡

        WANG Yong,JIN Liang-an,2,CHI Wei,QU Yi,2

        (1.Dept.of Navigation,Dalian Naval Academy,Dalian Liaoning 116018,China;2.Dalian Institute of Chemical Physics,Chinese Academy of Sciences,Dalian Liaoning 116023,China)

        0 Introduction

        Movement of rising bubble exists in the nature,such as rivers,lakes or sea.And it has been widely applied in chemical,environmental and maritime engineering or shipping fields etc[1-3].There are numerous experimental and theoretical studies focused on hydrodynamic characteristic of rising bubble in liquid,the influence of liquid characteristics on bubble behaviors,and the interaction between bubbles[4-11].But the interaction of bubble and surrounding liquid has not been studied.However,the interaction effect,especially the carrying effect of rising bubble,can directly influence on the fluid behavior and the transmittal efficiency of gas-liquid two-phase flow.So far it is a key point in design of engineering.In recent years,velocity field around rising bubble has been extensively studied by numerical simulation[12-15].However, lacking measurement method makes it hard to find experimentally measured results to validate these numerical simulations[16-17].Therefore,it is a realistic need to find an appropriate method to measure it accurately.

        Rising bubble's effect of carrying surrounding water is so complicated.It will not only induce an up-flow phenomenon in vicinity,but also a down-flow in outer region.However,its capacity to induce up-flow is more considerable in most industrial applications,such as bubble floatation and ship bubble wake removing[18].In order to provide more scientific basis for engineering application,this paper took bubble in water as an example,introduced a new concept,volume of up-flow water carried by bubble,to describe bubble capacity to carry water,and tried to find a feasible technology to measure it accurately.

        1 Material and method

        1.1 Design of method

        In bubble rising process,a range of vicinity water will move upward because of the interaction between two phases of gas and liquid,while the boundaries range is obviously difficult to determine.And the volume of upflow water carried by bubbles rising in water to a certain depth can be used to describe bubble's capacity to carry water.But this part of up-flow water was mixed with the still or down-flow water in outer region,so it is not easy to separate bubble carrying up-flow water effectively,even is difficult to measure it accurately for its small volume.In view of this,a novel method,dual-liquid separation and phase-change measurement,was put forward,its basic idea was introduced as follows.

        Dual-liquid system is composed of two immiscible liquid with different densities.In the experiment,diesel fuel and water were chosen.When they were mixed,an interface would naturally appear with their density difference,the up-liquid layer was diesel fuel,and down-liquid layer was water.When bubble rising in down-liquid(water)went beyond the interface,up-flow water surrounding bubbles would be carried to the up-liquid layer(diesel fuel).Simultaneously,under the carrying effect of diesel fuel's stable revolving,up-flow water just car-ried into up-liquid layer would be taken away from the upper region of down-liquid pool,and subside to the bottom of up-liquid pool for their density difference.So bubble carrying up-flow water would be successfully separated from the other water in the vicinity of bubble.

        As the volume of up-flow water is generally small,it is difficult to measure it accurately.So phase-change measurement was put forward,its basic idea was making separated up-flow water react rapidly and completely with sufficient special chemical to change the carried water from liquid-phase into gas-phase.For the volume of gas is about thousand times larger than that of water,it could be measured much more easily and precisely.And then,the volume of up-flow water carried by bubbles could be calculated accurately with measured gas volume by the ratio of gas-liquid volume in phasechange reaction.

        1.2 Design of experimental apparatus

        Based on the thought of dual-liquid separation and phase-change measurement,the experimental apparatus was specially designed,which includes separation device,phase-change device and basic device.

        1.2.1 Separation device

        Separation device was used to separate up-flow water carried by bubble.It was composed of two joined columniform container with different radius,named upperpool(1)and down-pool(2)respectively according to relative position(Fig.1).The diameter of the down-pool was smaller than the radius of upper-pool.The upperpool was inclined at a certain angle with its bottom lower than the topmost surface of the down-pool.In order to form a perfect up-liquid flow field,the down-pool should be located in the higher part of upper-pool.Fig.2 is the section sketch of A-A line of up-pool,which illustrates the device to form up-liquid flow field.In Fig.2,special oil pump is fixed outside of the upper-pool,its inlet and outlet are located on the inner wall of an upperpool,above the topmost surface of the down-pool.

        Fig.1 Experimental apparatus圖1 雙液分離轉(zhuǎn)相精測裝置

        Fig.2 Device to form up-liquid flow field圖2 上液流場形成裝置

        1.2.2 Phase-change device

        Phase-change device(Fig.1)was used to make specific chemical reactions,transform seperated up-flow water from liquid-phase to gas-phase,collect the gas and measure its volume.It was composed of two parts:one was phase-change reaction zone(4),the other was produced gas collection zone(5,6,7).Phase-change reaction zone was the lowest part of the upper-pool.Specific phase-change chemical set in advance would react with the seperated water rapidly and completely.Produced gas collection zone was used to collect gas produced in phase-change reaction.This part of the apparatus consist of gas collection tube(5),liquid container(6)and gas collector(7).

        1.2.3 Basic device

        Basic device was composed of bubble generator and interface controller.

        Bubble generator included compressed air source device(8a),check valve(8b),gas container(8c),gas flowmeter(8d)and nozzle(8e).The nozzle's diameter,shape,vertical depth and horizontal position were designed to be adjusted purposefully.

        Interface controller was connected with down-pool,and used to keep the dual-liquid interface(2a)locating at the topmost surface of down-pool.

        1.2.4 Device parameters

        As the design showed in 1.2.1 to 1.2.3,the parameters of the device were set up as follow:the upperpool was50cm diameter and 24cm height,its inclination was 3°;down-pool was 21cm diameter and 55cm height,it was located in the highest position of the upperpool.In experiments,0.5ml air was injected to form bubbles.To control small volume process conveniently,bubble generator was simplified,it was composed of 2ml syringe,infusion tube,and 2.5mm diameter nozzle.The nozzle was located in the center of down-pool,52cm away from the dual-liquid interface.

        1.3 Method

        In experiments,dual-liquid was water and diesel oil.0.5ml air was injected into water to form bubbles at normal temperature(20℃)and air pressure.When the up-flow water carried by bubble went beyond the interface and into the diesel oil,it would be effectively separated to the lowest part of upper-pool with the effect of stable revolving up-liquid flow and density difference.In this condition,volume of separated water was measured respectively by two methods,phase-change measurement and direct measurement,to compare their precision.

        In method of phase-change measurement,adequate phase-change chemical(NaO2)was put in phase-change reaction zone in advance to react with separated up-flow water rapidly and completely.Moreover,produced gas(O2)was gathered to measure its volume(Vg)by 1000ml cylinder(Minimum scale 10ml),and the phasechange measuring volume of up-flow water(Vw1)could be calculated with gas-liquid volume ratio in phasechange chemical reaction.

        In method of direct measuring,separated up-flow water was managed to move away from the up-pool,and the volume would be measured by 20ml pipette or 10ml measuring cylinder(Minimum scale 0.1ml).So the direct measuring volume of up-flow water(Vw2)was got.

        In order to avoid the influence of measuring error,all of the experiments were repeated 10 times,and every repeat had 10 samples.

        2 Results and discussion

        2.1 Experimental results

        The data were showed in Tab.1,including the volume of gas produced in phase-change reaction(Vg),phase-change measuring volume of up-flow water(Vw1)deduced by Vg,direct measuring volume of up-flow water(Vw2),and relative error((Vw2-Vw1)/Vw1).

        Table 1 Volume of up-flow water carried by bubbles with different measurements(Average±Standard error)表1 氣泡上升攜帶水量的比對測量實(shí)驗(yàn)結(jié)果

        In Table 1,the average of phase-change measuring water volume is about 1.76311ml,its standard error is±0.0026~0.0040.While the average of direct measuring water volume is 1.743ml,its standard error is±0.043~0.130.Furthermore,the maximum relative error of each pair data is about 13.47%,the minimum is only 0.51%,and the average relative error is about 5.798%.

        2.2 Analysis and discussion

        Result shows that up-flow water volume carried by bubbles could be measured more accurately by dual-liquid separation and phase-change measurement.It is mainly due to enlargement measuring with phase-change by special chemical reaction,which reduces the influence of estimation error obviously.

        Supposed that up-flow water volume was measured directly with 20ml pipette or 10ml graduated flask(minscale 0.1ml),the estimate error was about 0.01ml,occupying 0.57%of the average value(1.743ml).While in dual-liquid separation and phase-change measurement,water has been changed into gas,and its volume has been enlarged about 2000 times.Although the estimate error of produced gas volume was 1ml,occupying only 0.03%of the average volume(3290.9ml),it didn't have obvious effect on measuring accuracy.That is to say,the larger produced gas volume could be measured more accurately than smaller up-flow water volume.

        In addition,the up-flow water volume measured by phase-change measurement would be calculated with produced gas volume.In experiments,NaO2was chosen as phase-change chemical,and the reaction equation was:

        According to this equation,the molar ratio of produced gas(O2)and liquid(H2O)is 3∶2,so the gasliquid volume ratio is 1866.6∶1.That is to say,to get the up-flow water volume,produced gas volume would be reduced nearly 2000 times,so the impact of estimate error on the measuring result would be furthermore reduced,even could be negligible,and the up-flow water volume could be measured more accurately.So the feasibility of dual-liquid separation and phase-change measurement was validated.

        Moreover,the choice of phase-change material would influence the gas-liquid volume ratio of phasechange chemical reaction,and directly affected the accuracy of dual-liquid separation and phase-change measurement.

        In experiments,the chosen phase-change material should be stable in diesel fuel,and react with water quickly.The produced gas should be insoluble in water,and the resultant of reaction should be non-corrosive or low-corrosive.The phase-change material we can choose usually includes:active alkali metal or alkaline-earth metals,Li,Na,K,etc;alkali metals and alkalineearth metal hydride,NaH,CaH2,KH,etc;peroxide and superoxide,CaO2,CaO4,etc;metal carbides,Al4C3and so on.When different phase-change material was chosen,the volume of produced gas is about 300 to 2000 times than that of water.With the larger volume ratio of gas and liquid,the measuring error of dual-liquid separation and phase-change measurement is smaller,so its accuracy is relatively higher.

        Result also shows that the superiority of dual-liquid separation and phase-change measurement is more obvious in smaller volume system.

        With ascending sort the phase-change measuring volume of up-flow water carried by bubble,we can get Fig.3.

        Fig.3 Compare of up-flow water volume by different measurements圖3 氣泡上升攜帶水量測量結(jié)果的比較

        As Fig.3 shows,data in these two methods,direct measurement and phase-change measurement,are all in the range of 1 ~2.5ml,and the direct measuring group is generally smaller.When the volume of bubble carrying up-flow water is relatively larger,two measuring data are nearly equal,such as the sixth,seventh,eighth and tenth groups in Fig.3.However,while up-flow water volume is small,the relative error of these two measuring data will become obvious,such as the first,second,forth and fifth groups.So the feasibility of dual-liquid separation and phase-change measurement was validated.Especially when the water volume is smaller,phase-change method can accurately offer the volume of up-flow water carried by bubbles,but direct method can not for its too big inherent error.

        3 Conclusions

        In order to solve the problem of lacking method to separate and measure up-flow water carried by bubble,experimental apparatus was specially designed.With water and diesel oil as dual-liquid system,the volume of up-flow water carried by bubble was measured by two different methods:direct measurement and phasechange measurement.Results show that up-flow water carried by bubble can be effectively separated,and that the phase-change method of measuring dual-liquid separation is precisely higher than that of direct measurement.Phase-change method can accurately offer the volume of up-flow water carried by bubbles especially in small volume system than direct measurement method which has a big inherent error.So it was validated that dual-liquid separation and phase-change measurement is valuable to deeply experimental study of bubble's capac-ity to carry surrounding water.

        Moreover,it was also observed that measuring precision of this new technology might be influenced by many factors,such as dynamic viscosity of up-liquid,environmental temperature and air pressure,bubble size and distribution,and entireness of phase-change reaction et al.These influence rules will be deeply investigated in the future.

        [1] CHE De-fu,LI Hui-xiong.Multiphase fluid and its application[M].Xi'an:Xi'an Jiaotong University Press.2007.

        [2] DENG Sheng,LI Hui-xiong,ZHAO Jian-fu,et al.Numerical simulation of the interface movement in gas-liquid two-phase flows[J].Journal of Xi'an Jiaotong University.,2004,38(11):1123-1127.

        [3] ZHANG Lei,LIU Ping,LIU Chun,et al.Micro-bubbles and its application in control of environmental pollution[J].Hebei Journal of Industrial Science and Technology,2011,28(1):59-63.

        [4] CLIFT R,GRACE J R,WEBER M E.Bubbles,drops,and particles[M].New York:Academic Press,1978.

        [5] JIA Fu,LIU Yi-nian,CHEN Xue-wu.Turbulence characteristics of rising bubble cluster[J].Science in China,Ser.A,1991,34(5):486-493.

        [6] CHEN N C,CHOU I S.Wake structure of a single bubble rising in a two dimensional column[J].Experimental Thermal and Fluid Science,1998,17(3):165-178.

        [7] SMOLIANSKI A,HAARIO H,LUUKKA P.Numerical study of dynamics of single bubbles and bubble swarms[J].Applied Mathematical Modelling,2008,32(1):641-659.

        [8] AMAYA-BOWER L,LEE T.Single bubble rising dynamics for moderate Reynolds number using lattice Boltzmann method[J].Computers & Fluids,2010,39(7):1191-1207.

        [9] JIANG Shao-kun.Bubble behavior in non-Newtonian fluids[D].Tianjin:Tianjin University,2007.

        [10] WANG Han,ZHANG Zhen-yu,YANG Yong-ming,et al.Surface tension effects on the behavior of two rising bubbles[J].Journal of Hydrodynamics,Ser.B,2011,23(2):135-144.

        [11] YU Zhao,YANG Hui,F(xiàn)AN Liang-shi.Numerical simulation of bubble interactions using an adaptive lattice Boltzmann method[J].Chemical Engineering Science,2011,66(14):3441-3451.

        [12] ELLINGSEN K,RISSO F.On the rise of an ellipsoidal bubble in water oscillatory paths and liquid-induced velocity[J].Journal of Fluid Mechanics,2001,440(1):235-268.

        [13]SANADA T,WATANABE M,F(xiàn)UKANO T,et al.Behavior of a single coherent gas bubble chain and surrounding liquid jet flow structure[J].Chemical Engineering Science,2005,60(1):4886-4900.

        [14] FAN Wen-yuan,MA You-guang,LI Xiao-lei,et al.Study on the flow field around two parallel moving bubbles and interaction between bubbles rising in CMC solutions by PIV[J].Chinese Journal of Chemical Engineering,2009,17(6):904-913.

        [15]AMAYA-BOWER L,LEE T.Numerical simulation of single bubble rising in vertical and inclined square channel using lattice Boltzmann[J].Chemical Engineering Science,2011,66(5):935-952.

        [16] XU Shang,WANG Yong,HAN Yun-dong,et al.Influence of air injecting rates on bubble's capacity to carry water[J].Chemical Engineering(China),2011,39(6):76-78.

        [17] WANG Yong,JIN Liang-an,XU Shang,et al.Experimental research for influence of injecting depth on water volume carried by bubbles[J].Journal of Experiments in Fluid Mechanics,2011,25(6):49-53.

        [18] TIAN Heng-dou.Study on control technology of ship bubble wake[D].Dalian:Dalian Naval Academy,2011.

        猜你喜歡
        雙液液流氣泡
        檸檬氣泡水
        欣漾(2024年2期)2024-04-27 15:19:49
        SIAU詩杭便攜式氣泡水杯
        新潮電子(2021年7期)2021-08-14 15:53:12
        浮法玻璃氣泡的預(yù)防和控制對策
        雙液注漿
        北方建筑(2020年6期)2020-12-14 12:41:33
        化學(xué)實(shí)驗(yàn)探究中雙液原電池裝置的應(yīng)用
        名師在線(2020年12期)2020-05-06 01:36:22
        冰凍氣泡
        一種全釩液流電池并網(wǎng)控制系統(tǒng)的仿真設(shè)計(jì)
        淺談WSS注漿堵漏加固在應(yīng)急工程中的應(yīng)用
        科技尚品(2016年3期)2016-05-30 02:39:17
        H2-Fe3+/Fe2+氧化還原液流電池初步研究
        WSS工法雙液注漿技術(shù)在市政工程中應(yīng)用
        国产免费拔擦拔擦8x高清在线人| 日韩精品一区二区在线视| 久久老熟女一区二区三区福利| 狠狠97人人婷婷五月| 一本久久a久久精品亚洲| 甲状腺囊实性结节三级| 一二三四在线观看韩国视频| 欧洲美女黑人粗性暴交视频| 老外和中国女人毛片免费视频 | 中文字幕一区二区三区人妻精品 | 国产乱国产乱老熟300部视频| 99久久婷婷国产综合亚洲91| 91亚洲精品久久久蜜桃| 国产精品国产三级野外国产| 中国少妇内射xxxx狠干| 国产在线观看入口| 丰满人妻一区二区三区免费| 亚洲国产成人av二区| 人妻av乱片av出轨| 欧美日韩免费一区中文字幕| 少妇人妻av一区二区三区| 内射人妻无套中出无码| 又黄又爽又色的视频| 中文字幕人妻系列一区尤物视频| 国产三级精品三级在线专区| 色www永久免费视频| 日本免费人成视频播放| 亚洲国产都市一区二区| 加勒比色老久久爱综合网| 乱人伦视频中文字幕| 国产真实伦视频在线视频| 一区二区二区三区亚洲 | 欧洲亚洲色一区二区色99| 亚洲毛片免费观看视频| 久久久久久亚洲av无码蜜芽| 国产在线不卡AV观看| 国产三级视频在线观看国产| 真实国产乱子伦精品视频| 久久精品岛国av一区二区无码| 日韩精品中文字幕人妻中出| 午夜视频在线瓜伦|