        Influence of soil resistivity on stray current in power supply system of urban rail transit

        2022-09-19 06:50:30CHENWanglongLIYaningWANGYe

        CHEN Wanglong, LI Yaning, WANG Ye

        (1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China;2. School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China)

        Abstract: In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit, we establish an equivalent circuit model of the rail-to-ground structure based on resistance network method first. After measuring the soil resistivity of a real subway system, a simulation model is established in Matlab to obtain the stray currents at different soil resistivities. Then the influence of soil resistivity on stray current is analyzed. Afterwards, to verify the rationality and reliability of the simulation model, we design a test circuit to measure the stray current and rail-to-ground voltage in a real subway system, and a comparison of the experimentally measured results and simulation results is presented. The results show that the stray current is the maximum when the soil resistivity is 211.57 Ω·m; when the soil resistivity is 768.47 Ω·m, the stray current is the minimum, that is, the smaller the soil resistivity, the greater the stray current. Therefore, the resistivity should be increased as much as possible when ramming the track foundation in urban rail transit system.

        Key words: urban rail transit; power supply system; stray current; soil resistivity; four-electrode method

        0 Introduction

        The urban rail transit features fast speed, punctuality, large carrying capacity and low energy consumption so that it plays an increasingly important role in people’s daily lives. Accordingly, there exist currents leaking from the railway tracks into the ground, which is called stray currents caused by various elements[1-3]. At present, the research on stray currents mainly focuses on optimization of circuit model of rail-to-ground structure[4], design of current drainage net[5-8], electrochemic corrosion mechanism of metal pipelines[9], dynamic characteristics of stray current[10], layout of traction power supply structure[11-12], selection of grounding modes of traction substation[13], magnitude of resistivity[14]and voltage level of traction substation[15], etc. However, most of them focus on simulation analysis but lack of experimental data. Moreover, the theoretical analysis and experimental test on soil properties is uncomprehensive although soil resistivity is an important factor which affects the spatial and temporal distribution of stray current but is rarely reported. In our work, the influence of soil resistivity on stray current is studied by simulation and experimental tests on the soil of a real subway system.

        1 Equivalent circuit of rail-to-ground structure

        Taking a real subway system as the research object, considering the existence of stray current, we establish the equivalent circuit model of rail-to-ground structure with the distribution of stray current, as shown in Fig.1.

        Fig.1 Equivalent circuit diagram of rail-to-ground structure of a subway system

        The traction substation is regarded as the current source(I), each metal structure of the rail is regarded as a resistor(R), and the rail is regarded as being composed of series resistors. The transition resistance between the rail and the ground is represented asRg, and soil resistance is represented asRt. Based on this, letα2=R/Rg, we can derive the changing laws of stray current and rail-to-ground voltage as[17-19]

        (1)

        (2)

        wherexis the distance from any point on the rail to the substation;Lis the distance between the locomotive and traction power substation;u(x) is the voltage at positionx; andis(x) is the stray current at positionx.

        2 Measurement of soil resistivity

        Soil resistivity is defined as the average value of soil resistance per unit length. It directly affects the grounding resistance of grounding device as well as the voltage distribution of ground network. Fig.2 shows the schematic diagram to measure the soil resistivity by means of four-electrode method.

        Fig.2 Schematic diagram of measuring soil resistivity by four-electrode method

        Soil resistivity can be got by

        (3)

        Table 1 Measurement results of soil resistivity

        3 Simulation of stray current and rail-to-ground voltage

        3.1 Simulation of stray current

        According to the equivalent circuit model of the rail-to-ground structure in section 1, we can establish the simulation model of stray currents based on Matlab, as shown in Fig.3.

        Fig.3 Simulation model of stray current and rail-to-ground voltage distribution

        Fig.4 Simulation results of stray currents

        The stray current distribution within a given rail section is shown in Fig.5.

        Fig.5 Stray current distribution within a given rail section

        It can be seen that in the direction parallel to the rail, the stray current increases first and then decreases, and its maximum value occurs in the middle of the rail section; in the direction perpendicular to the rail, the stray current decreases from the rail to both ends.

        3.2 Simulation of rail-to-ground voltage

        Fig.6 Simulation results of rail-to-ground voltage

        The rail-to-ground voltage distribution within a given rail section is shown in Fig.7. It can be seen that in the direction parallel to the rail, the rail-to-ground voltage reaches the maximum at the track terminal and then linearly decreases to the minimum in the middle of the the track section; in the direction perpendicular to the rail, the rail-to-ground voltage decreases from the rail to both ends.

        Fig.7 Rail-to-ground voltage distribution within a given rail section

        4 Experimental verification

        To verify the rationality and reliability of the simulation model, we design a test circuit[16]to measure the stray current and rail-to-ground voltage in a real subway system, as shown in Fig.8. A Fistech FT10010 DC power supply (output voltage: 0-100 V, output current: 0-10 A) is used to simulate the traction substation, and 11 cement resistors in series (R=1 Ω,P=10 W) are used to simulate the rails. Ten 7-cm probes are inserted into the soil at an interval of 4 cm between probes, and every probe is welded to the corresponding nodes between the two rail resistors. The negative pole of VICTOR 98A+ voltmeter is connected to the soil and its positive pole is connected to the nodes. In this way, the voltage between the node and the soil can be measured. The measured traction current values are displayed on ammeter A1, the measured stray current values are displayed on ammeter A2, and the measured rail-to-ground voltage values are displayed on voltmeter V. In our study, when the traction current is 0.5 A, 1.0 A, 1.5 A and 2 A, respectively, the average values of stray currents and rail-to-ground voltage are obtained through three times’ measurement.

        Fig.8 Measuring principle diagram of stray current and rail-to-ground voltage

        The simulation results and experimental results of stray currents and rail-to-ground voltages at different soil resistivities are compared and analyzed, as shown in Figs.9-10.

        It can be seen from Fig.9 that with the increase of the traction current, the stray current flowing into the ground increases. If the the traction current is fixed, with the increase of soil resistivity, the stray current decreases. The maximum error between the simulation results and the measured results is about 1.5%, which is caused probably by the thermal effect of resistance, the error between the Matlab simulation calculation model and the experimental measurement.

        Fig.9 Comparison of experimental and simulation results of stray current

        It can be seen from Fig.10 that with the increase of the traction current, the amplitude of rail-to-ground voltage reaches the maximum at both ends of the track section and the minimum in the middle of the track section. The maximum error between the simulation results and the measured results is about 5%.

        Fig.10 Comparison of simulation and experimental results of rail-to-ground voltage

        5 Conclusions

        Through the simulation analysis and experimental verification of stray current and rail-to-ground voltage at different soil resistivities, the conclusions are as follows:

        2) With the increase ofthe traction current, the amplitude of rail-to-ground voltage reaches the maximum at both ends of traction section and reaches the minimum in the middle of traction section.

        3) The error between the simulation results and the experimental results of the stray current is about 1.5%, and error of the rail-to-ground voltage is about 5%.

        中文精品久久久久中文| 欧美另类人妖| 中文字幕有码无码av| 久久国产成人午夜av影院| 成人av在线免费播放| 亚洲中文久久精品字幕| 国产特级毛片aaaaaa| 国产午夜亚洲精品不卡福利| av福利资源在线观看| 国产精品久久久免费精品| 欧美日韩在线视频一区| 精品深夜av无码一区二区老年| 国产精品丝袜黑色高跟鞋| AV无码人妻一区二区三区牛牛| 久久99免费精品国产| 亚洲av不卡无码国产| 久久精品麻豆日日躁夜夜躁| 亚洲一区视频在线| 玩弄丝袜美腿超短裙校花| 插插射啊爱视频日a级| 9lporm自拍视频区| 人妻无码视频| 国内精品久久人妻互换| 国产精品国产三级野外国产| 一进一出一爽又粗又大| 欧美日韩国产免费一区二区三区欧美日韩 | 亚洲精品中文字幕乱码二区| 亚洲精品在线免费视频| 国产伦理一区二区| 99精品视频在线观看| 亚洲熟妇夜夜一区二区三区| 蜜桃视频在线观看网址| 无人视频在线观看免费播放影院 | 强行无套内谢大学生初次| 精品欧美久久99久久久另类专区| 玩弄极品少妇被弄到高潮| 国产三级不卡一区不卡二区在线| 无码人妻一区二区三区免费视频| 中文字幕有码无码av| 亚洲大尺度动作在线观看一区| 国产一区二区资源在线观看|