        Thermodynamic Analysis of a Condensate Heating System from a Marine Steam Propulsion Plant with Steam Reheating

        2021-06-17 03:16:02VedranMrzljakIvanLorencinNikolaAneliZlatanCar

        Vedran Mrzljak·Ivan Lorencin·Nikola An?eli?·Zlatan Car

        Abstract The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy analysis of any condensate heating system should be avoided because it is highly influenced by the measuring equipment accuracy and precision.All the components from the observed marine condensate heating system have energy destructions lower than 3 kW,while the energy efficiencies of this system are higher than 99%.The exergy efficiency of closed condensate heaters continuously increases from the lowest to the highest steam pressures(from 70.10%to 92.29%).The ambient temperature variation between 5°C and 45°C notably influences the exergy efficiency change of both low pressure heaters and the low pressure segment equal to 31.61%,12.37%,and 18.35%,respectively.

        Keywords Condensateheatingsystem.Marinesteampropulsionplant.Steamreheating.Thermodynamicanalysis.Energyand exergy analyses.Segmental analysis.Ambient temperature change

        1 Introduction

        Modern steam power plants consist of various systems that improve the entire plant operation(Li et al.2017;Chen et al.2017a).One such system is a condensate heating system mounted between the main condenser and steam generator(Abdella and Nassar 2019)in which the condensate is heated by steam extracted from the main turbine cylinders(Rocha and Silva 2019;Hoseinzadeh and Heyns 2020).The main goal of the condensate heating system is to reduce fuel consumption and simultaneously increase overall plant efficiency(Woodruff et al.2004;Oyedepo et al.2020).

        Many researchers have investigated condensate heating systems and their components as part of a steam power plant analysis.Naserabad et al.(2019)presented multi-objective optimization of condensate heater arrangement options in a steam power plant repowering.Economic and thermal performance analysis of a 210-MW coal-fired steam power plant was presented by Kumar et al.(2014),where the components of the existing condensate heating system were investigated in detail.These authors have also presented several improvement options.Chauhan and Khanam(2019)used pinch analysis to integrate improvements from the energy aspect in a 250-MW thermal power plant.It was concluded that the best integration option was to close one extraction,which leads steam to the condensate heater nearest the main condenser.Zhao et al.(2018)performed dynamic simulation that shows that the operational flexibility of a 660-MW coal-fired steam power plant can be improved by regulating steam extractions to high pressure condensate heaters.The fatigue lifetime assessment of a high pressure heater in supercritical coal-fired power plants was investigated by Zhao et al.(2019).These authors concluded that such a heater obtains maximum mechanical stresses before it reaches thermal stresses.Many researchers performed failure analysis of various condensate heaters from thermal or nuclear power plants(Zangeneh and Bakhtiari 2019;Ramesh and Manavalan 2019;Fulger et al.2019).Several operation schemes of condensate heaters were investigated by Wijaya and Widodo(2019)using Cycle-Tempo software,while Geete(2020)investigated the possibilities of using a parabolic solar collector in condensate heating systems.

        During energy and exergy analyses of steam power plants,condensate heating system components are commonly considered.Energy and exergy analyses of a 200-MW steam power plant along with an investigation of the optimal number of condensate heaters were presented by Kamil Mohammed et al.(2019).Kumar et al.(2018)performed energy and exergy analyses of a coal-fired power plant along with an investigation of a currently operating condensate heating system.Similar research for various power plants can be found in the papers by Khan et al.(2019),Kowalczyk et al.(2019),and Adeli et al.(2020).Kaushik et al.(2011)and Ray et al.(2010)presented reviews,equations,methods,and techniques for energy and exergy analyses of various thermal power plants that include condensate heating systems and their components.The results show that proper condensate heating system operation significantly influences the performance of the entire power plant.

        The energy and exergy analyses of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating are performed in this paper.It is found that the energy analysis of this system is highly influenced by the measurement equipment accuracy and precision,and it can provide unrealistic results,so the exergy analysis is favored.A detailed literature review shows that an ambient temperature change analysis for each component of any condensate heating system has not been performed to date.This analysis shows that the condensate heater nearest the steam condenser is highly influenced by an ambient temperature change.Moreover,the ambient temperature change has an important influence on the entire low pressure heating segment,which is useful for proper design and maintenance.

        2 Marine Steam Propulsion Plant with Steam Reheating

        Current marine propulsion plants are mainly based on internal combustion engines(Prasad Sinha and Balaji 2018;Cherednichenko and Serbin 2018;Sen?i?et al.2019;Lamas Galdo et al.2020).However,steam propulsion plants remain dominant for LNG carrier drives because of their high reliability,operational flexibility,and specificity of transported cargo(Adamkiewicz and Grzesiak 2019).Older versions of marine steam propulsion plants have a main turbine composed of two cylinders(high pressure turbine(HPT)cylinder and low pressure turbine(LPT)cylinder)and do not perform steam reheating(Mrzljak et al.2017a;Mrzljak and Poljak 2019).Newer versions of these steam propulsion plants,as presented in Figure 1,perform steam reheating and had an additional cylinder(intermediate pressure turbine(IPT)cylinder).

        Presently,marine steam propulsion plants(with and without reheating)can be found on various LNG carriers.The total produced power in such plants is between 35 MW and 45 MW(Fernández et al.2017)and includes the main turbine,all turbo-generators,and the low power steam turbine for the main condensate pump drive(Kocijel et al.2020).However,steam propulsion plants can also be effectively used in other marine vessels,such as crude oil carriers.

        Steam reheating application increases the overall plant efficiency and divides the main turbine at three cylinders.All main turbine cylinders are connected to the shaft,which drives the main propulsion propeller through the gearbox(Song et al.2015).The steam propulsion plant presented in Figure 1 is used for the crude oil carrier drive,and the main turbine maximum power is 17 MW(Koroglu and Sogut 2018).

        3 Description and Characteristics of the Analyzed Marine Condensate Heating System

        The analyzed condensate heating system(Figure 2)consists of five basic components,four of which are closed condensate low pressure and high pressure heaters(LPH1,LPH2,HPH1,and HPH2).Closed condensate heaters are recuperative heat exchangers in which heat transfer occurs through pipe walls,so the heating medium and main condensate are not mixed together.

        The fifth basic component of the analyzed system is the deaerator,which has a dual function.The deaerator is an open condensate heater in which the heating medium(steam)and the main condensate are mixed.The second deaerator function is dissolved gas removal(deaerating process)to prevent erosion(Chen et al.2017b).

        Along with the five basic components,the analyzed marine condensate heating system consists of several pressure reduction valves and pumps.

        4 Equations for the Energy and Exergy Analyses

        4.1 Governing Equations for the Energy and Exergy Analyses of Any Control Volume

        Energy analysis of any control volume is defined by the first law of thermodynamics(Aljundi 2009;Elhelw et al.2019;Ahmadi et al.2018;Kano?lu et al.2012).For any control volume,the energy balance equation can be defined as Adibhatla and Kaushik(2017a),where in the most cases,potential and kinetic energies can be disregarded(Medica-Viola et al.2020a):

        Figure 1 Scheme of the marine steam propulsion plant with steam reheating

        In Eq.1,Q·is heat energy transfer,P is mechanical power,while indexes IN and OUT denotes input and output.E·n is the total energy of a fluid flow defined according to(Bla?evi? et al.2019):

        where m·is mass flow rate and h is specific enthalpy.

        Exergy analysis of any control volume is defined by the second law of thermodynamics(Naserbegi et al.2018;Adibhatla and Kaushik 2017b).The exergy balance equation is(Medica-Viola et al.2020b):

        Figure 2 Analyzed marine condensate heating system,its segments,and components

        whereεis the specific exergy of the fluid stream(Tan et al.2018):

        In Eq.5,s is specific entropy,while X·heatrepresents the heat exergy transfer at temperature T:

        Energy and exergy efficiencies of any control volume can be defined as

        During control volume operation,fluid mass flow rate leakage usually does not occur,so the valid mass flow rate balance is(Lorencin et al.2019a)

        4.2 Equations for the Energy and Exergy Analyses of the Investigated Heaters

        Energy and exergy analyses of all condensate heaters are performed using equations from Erdem et al.(2009),Uysal et al.(2017),and Noroozian et al.(2017).All the equations are developed according to the operating points from Figures 1 and 2(green marked points).The energy analysis equations are presented in Table 1.

        4.3 Equations for the Energy and Exergy Analyses of Segments and the Overall Heating System

        In many research papers can be found the energy and exergy analyses of each heater from a condensate heating system(Zhao et al.2017).This paper offers a certain upgrade.

        The observed marine condensate heating system is divided into two segments.The first segment is a low pressure heating segment,which encompasses both low pressure condensate heaters(LPH1 and LPH2).The second segment(high pressure heating segment)contains both high pressure condensate heaters(HPH1 and HPH2)(Figure 2).The deaerator is a component that divides the condensate heating system in two presented segments;it is analyzed separately as a component and within the entire system.The energy analysis equations of the overall condensate heating system and its segments are presented in Table 2.

        Table 1 Energy analysis equations of condensate heaters

        Table 2 Energy analysis equations of the condensate heating system and its segments

        5 Data Required for the Energy and Exergy Analyses

        All fluid stream data required for the energy and exergy analyses of the marine condensate heating system,its segments,and components were found in Koroglu and Sogut(2018)and are presented in Table 3.The specific enthalpy and specific entropy of each fluid stream are calculated using NIST REFPROP 9.0 software(Lemmon et al.2010).The specific exergy of each fluid stream at the selected base ambient state is calculated using Eq.5.

        6 Energy and Exergy Analysis Results

        6.1 Energy and Exergy Analyses in the Base Ambient State

        The results of the energy analysis of the marine condensate heating system,its segments,and components are presented in Figure 3.The energy destruction of LPHS is higher than that of HPHS and mostly caused by energy destruction of LPH2(Figure 3).LPH2 and the deaerator have the highest energy destructions,while all other condensate heating systemcomponents have energy destructions lower than 1 kW.Comparison of all five components(heaters)shows that the lowest energy efficiency has LPH2(99.877%).Because of the LPH2 influence,LPHS has a lower energy efficiency(99.927%)than that of HPHS(99.988%).The overall condensate heating system has an energy destruction equal to 4.77 kW and an energy efficiency equal to 99.976%,as presented in Figure 3.

        Table 3 Thermodynamic data of required fluid streams

        Figure 3 Energy efficiencies and destructions(losses)of the condensate heating system,its segments,and components

        The results of the energy analysis lead to the conclusion that this analysis should be avoided for any condensate heating system,its segments,or components.Low energy destructions(and simultaneously high energy efficiencies)do not allow even the smallest errors during data acquisition.While observing HPH2,a decrease in steam specific enthalpy(operating point 4,Table 3)of 0.2 kJ/kg led to a negative energy destruction and to an energy efficiency higher than 100%,which is practically impossible.

        By observing all the components(heaters)from the analyzed marine condensate heating system at the base ambient state,it can be easily noted that the deaerator has the dominant exergy power inputs and outputs(Figure 4).HPHS has approximately threefold higher exergy power inputs and outputs than those of LPHS.The overall condensate heating system has an exergy power input equal to 5 278.31 kW,while its exergy power output equals 4 718.9 kW.

        In the base ambient state of the observed condensate heating system,the deaerator is the component with the lowest exergy destruction(70.74 kW)and the highest exergy efficiency(95.96%)(Figure 5).High pressure condensate heaters have much higher exergy efficiencies than those of low pressure heaters.HPH1 has a lower exergy efficiency(88.12%)than that of HPH2(92.29%)because of a higher exergy destruction.In the low pressure heating segment,LPH2 has a higher exergy efficiency(79.36%)than that of LPH1(70.10%),despite the higher exergy destruction.

        Figure 4 Exergy power inputs and outputs of the condensate heating system,its segments,and components(base ambient state)

        Figure 5 Exergy efficiencies and destructions of the condensate heating system and its segments and components(base ambient state)

        Despite its lower exergy destruction,LPHS has a lower exergy efficiency(75.34%)than that of HPHS(89.63%)(Figure 5).Overall,the analyzed condensate heating system has an exergy destruction of 559.41 kW,while its exergy efficiency is 89.40%.Compared with the energy analysis,the exergy analysis of the observed(and any other)condensate heating system is less sensitive to the measuring equipment accuracy and precision(Naserbegi et al.2018),and it can be recommended.

        6.2 Exergy Analysis During the Ambient Temperature Change

        A literature review shows that several researchers have investigated the ambient temperature influence on steam power plant components.The general conclusion is that most steam power plant components are not significantly influenced by the ambient temperature change.As an example,Ameri et al.(2009)showed that an ambient temperature change of 10°C resulted in a 1%or smaller exergy efficiency change of high power steam turbines.The same conclusion is reached in Mrzljak et al.(2017b)for marine auxiliary low power steam turbines.However,Ahmadi and Toghraie(2016)showed that most steam power plant components are not significantly influenced by the ambient temperature change but found exceptions in steam generators and low pressure steam turbine cylinders.Kopac and Hilalci(2007)and Aljundi(2009)found that condensate heaters from land-based steam power plants are slightly influenced by an ambient temperature change.As opposed to land-based steam power plants,Poljak et al.(2020)showed that an ambient temperature change can notably influence heat exchangers from a marine steam power plant.

        In this paper,the ambient temperature influence on the analyzed marine condensate heating system,its segments,and components is also investigated.The observed ambient temperature range is set from 5 to 45°C,and the calculations are performed in steps of 10 °C.An analysis of condensate heating system components(heaters)shows that the exergy destruction of each heater increases with the ambient temperature,as presented in Figure 6.

        An increase in the ambient temperature decreases the exergy efficiencies of all heaters(Figure 7).The ambient temperature change slightly influenced the exergy efficiencies of HPH2,the deaerator,and HPH1 and highly influenced those of both low pressure heaters(LPH2 and LPH1)(Figure 7).In the observed ambient temperature range,the cumulative exergy efficiency change of HPH2,the deaerator,and HPH1 equals 2.55%,3.83%,and 4.43%,respectively,while that of LPH2 and LPH1 is 12.37%and 31.61%,respectively.

        Figure 6 Exergy destruction of condensate heating system components during an ambient temperature change

        Figure 7 Exergy efficiency of condensate heating system components during an ambient temperature change

        The important conclusion derived from this observation is that the influence of the ambient temperature differs between condensate heaters.The exergy efficiency of a condensate heater mounted nearest the main condenser is highly influenced by the ambient temperature change.Because of this fact,attention should be paid to the design and operation of this condensate heater.

        The exergy destructions of LPHS and HPHS,as well as the overall condensate heating system,increase with the ambient temperature(Figure 8).The change in the ambient temperature resulted in a more intensive exergy destruction change of HPHS(in comparison with that of LPHS).In the observed ambient temperature range,the exergy destruction of the entire condensate heating system increases from 543.21 kW(at 5°C)to 620.73 kW(at 45°C)(Figure 8).

        For the overall condensate heating system and both of its segments(as for the heaters),it is also valid that an increase in the ambient temperature decreases exergy efficiencies.Figure 9 shows that the exergy efficiencies of HPHS and the overall condensate heating system are not significantly influenced by the ambient temperature change.However,the ambient temperature change has a notable influence on the LPHS exergy efficiency.In the observed ambient temperature range,the cumulative change in the exergy efficiency of HPHS,the overall condensate heating system,and LPHS is 3.69%,6.23%,and 18.35%,respectively.This fact leads to the conclusion that the entire LPHS(not only the condensate heater nearest the main condenser)should be carefully designed and maintained.

        Figure 8 Exergy destruction of the condensate heating system and its segments during an ambient temperature change

        Figure 9 Exergy efficiency of the condensate heating system and its segments during the ambient temperature change

        Figure 10 shows the average percentage difference of exergy power output and input for the overall analyzed condensate heating system,its segments,and components in the observed ambient temperature range(from 5 to 45 °C).An average percentage difference of exergy power output and input higher than 2% indicates a notable exergy efficiency change during the change in the ambient temperature and vice versa.Therefore,an increase in the ambient temperature causes the largest exergy efficiency decrease of LPH1,LPHS,and LPH2,respectively.

        Further analysis,improvements and possible optimization of the marine condensate heating system will be performed using various artificial intelligence(AI)methods,algorithms,and techniques.Our research team has already successfully applied such AI methods in several marine systems(Lorencin et al.2019b;Baressi?egota et al.2020),for electrical power output prediction of a complex combined cycle power plant(Lorencin et al.2019c),and in various medical applications(Car et al.2020;Lorencin et al.2020).Therefore,we have enough reasons to believe that the abovementioned methods will be very useful in further investigations of the marine condensate heating system,its segments and components.

        Figure 10 Average percentage difference of exergy power output and input for the condensate heating system,its segments,and components in the observed ambient temperature range

        7 Conclusions

        This paper presents a thermodynamic(energy and exergy)analysis of the condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating.It is found that energy analysis of any condensate heating system(not only of the observed one)should be avoided,because it can give unrealistic results caused by measurement equipment inaccuracy and imprecision.In the observed marine condensate heating system,the energy power losses related to any component did not exceed 3 kW,while the energy efficiencies were higher than 99%.

        Exergy analysis of condensate heating systems is an effective evaluation approach.In the base ambient state,the deaerator from the analyzed system has a higher exergy efficiency and lower exergy destruction(95.96%and 70.74 kW,respectively)than those of all other heaters.In a properly balanced condensate heating system,exergy efficiencies of closed condensate heaters should continuously increase from the lowest to the highest steam pressure.In the analyzed system,exergy efficiencies of closed condensate heaters in the base ambient state continuously increase from 70.10%to 92.29%,while the exergy efficiency of the low pressure heating segment(75.34%)is much lower than that of the high pressure heating segment(89.63%).The entire observed condensate heating system has an exergy destruction of 559.41 kW and an exergy efficiency of 89.40%in the base ambient state.

        Components and segments of the marine condensate heating system are not equally influenced by the ambient temperature change.The exergy efficiency of the closed condensate heater mounted nearest the main condenser is the most influenced by the ambient temperature change.In the performed analysis,a change in the ambient temperature from 5 to 45°C causes an LPH1 exergy efficiency change of 31.61%,which is much higher than those of the other components.The ambient temperature change also has a notable influence on the exergy efficiency of the low pressure heating segment,whereas its influence on the exergy efficiency of the deaerator,high pressure heaters,and high pressure heating segment is slight.

        The average percentage difference of exergy power output and input can be used as an effective measure in the ambient temperature influence evaluation for any component or segment or for the entire condensate heating system.In the analyzed system,an average percentage difference of exergy power output and input higher than 2% indicates a notable exergy efficiency change during the change in the ambient temperature and vice versa.

        FundingThis research is supported by the Croatian Science Foundation under the project IP-2018-01-3739,CEEPUS network CIII-HR-0108,European Regional Development Fund under the grant KK.01.1.1.01.0009(DATACROSS),project CEKOM under the grant KK.01.2.2.03.0004,CEI project“COVIDAi”(305.6019-20),and University of Rijeka Scientific Grants uniri-tehnic-18-275-1447,uniritehnic-18-18-1146 and uniri-tehnic-18-14.

        丰满巨臀人妻中文字幕| 欧美性狂猛xxxxx深喉| 伊人久久网国产伊人| 亚洲中文字幕女同一区二区三区| 亚洲精品成人一区二区三区| 男人吃奶摸下挵进去啪啪软件 | 少妇性饥渴无码a区免费| 91精品一区国产高清在线gif| 欧美人与动牲交a精品| 亚州综合激情另类久久久| 丝袜美腿爆炒国产在线观看 | 亚洲精品一区久久久久一品av| 亚洲色www成人永久网址| 国产91 对白在线播放九色| 免费看男女啪啪的视频网站| 婷婷色婷婷开心五月四| 在线观看免费人成视频| 亚洲中文字幕在线爆乳| 自拍av免费在线观看| 亚洲人成网站18禁止| 婷婷午夜天| 亚洲国产精品综合久久20 | 内射白浆一区二区在线观看| 亚洲av综合av国产av| 不卡a v无码在线| 成人一区二区三区激情视频| 国产精品三级av及在线观看| 99re6热在线精品视频播放6| 中文字幕五月久久婷热| av黄页网国产精品大全| 国产免费人成视频在线观看| 激情久久无码天堂| 日韩精品视频av在线观看| 无码h黄肉3d动漫在线观看| 欲妇荡岳丰满少妇岳| 美女被射视频在线观看91| 亚洲天堂av在线网站| 人妻少妇边接电话边娇喘| 日韩欧美在线观看成人| 亚洲一区二区三区成人网| 男女啪动最猛动态图|