Stanislav Bondarenko, Volodymyr Filipenko, Michael Karpinsky, Olena Karpinska, Gennadiy Ivanov,Valentyna Maltseva, Ahmed Amine Badnaoui, Ran Schwarzkopf
Stanislav Bondarenko, Volodymyr Filipenko, Ahmed Amine Badnaoui, Department of Joint Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
Michael Karpinsky, Olena Karpinska, Department of Biomechanics, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
Gennadiy Ivanov, Department of Experimental Pathology, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
Valentyna Maltseva, Morphology of Connective Tissue Department, Sytenko Institute of Spine and Joint Pathology, Kharkiv 61124, Ukraine
Ran Schwarzkopf, Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital,Hospital for Joint Diseases, New York, NY 10003, United States
Abstract BACKGROUND Today, biological fixation of uncemented press-fit acetabular components plays an important role in total hip arthroplasty. Long-term stable fixation of these implants depends on the osseointegration of the acetabular cup bone tissue into the acetabular cup implant, and their ability to withstand functional loads.AIM To compare the strength of bone-implant osseointegration of four types of porous metal implants in normal and osteoporotic bone in rabbits.METHODS The study was performed in 50 female California rabbits divided into nonovariectomized (non-OVX) and ovariectomized groups (OVX) at 6 mo of age.Rabbits were sacrificed 8 wk after the implantation of four biomaterials [TTM,CONCELOC, Zimmer Biomet's Trabecular Metal (TANTALUM), and ATLANT]in a 5-mm diameter defect created in the left femur. A biomechanical evaluation of the femur was carried out by testing implant breakout force. The force was gradually increased until complete detachment of the implant from the bone occurred.RESULTS The breakout force needed for implant detachment was significantly higher in the non-OVX group, compared with the OVX group for all implants (TANTALUM,194.7 ± 6.1 N vs 181.3 ± 2.8 N; P = 0.005; CONCELOC, 190.8 ± 3.6 N vs 180.9 ± 6.6 N; P = 0.019; TTM, 186.3 ± 1.8 N vs 172.0 N ± 11.0 N; P = 0.043; and ATLANT,104.9 ± 7.0 N vs 78.9 N ± 4.5 N; P = 0.001). In the OVX group, The breakout forces in TANTALUM, TTM, and CONCELOC did not differ significantly (P = 0.066).The breakout force for ATLANT in the OVX group was lower by a factor of 2.3 compared with TANTALUM and CONCELOC, and by 2.2 compared with TTM (P = 0.001). In the non-OVX group, the breakout force for ATLANT was significantly different from all other implants, with a reduction in fixation strength by a factor of 1.9 (P = 0.001).CONCLUSION TANTALUM, TTM, and CONCELOC had equal bone-implant osseointegration in healthy and in osteoporotic bone. ATLANT had significantly decreased osseointegration (P = 0.001) in healthy and in osteoporotic bone.
Key Words: Animals; Bone-implant interface; Osteoporosis; Femur; Tantalum; Titanium
Today, biological fixation of uncemented press-fit acetabular components plays an important role in total hip arthroplasty. Long-term stable fixation of these implants largely depends on the osseointegration of bone tissue into the acetabular cup implant and their ability to withstand functional loads[1,2].
It has been established that both the implant surface and the condition of bone tissue are of great importance in the process of osseointegration[3]. Implant qualities including structure, strength, stiffness, porosity, coefficient of friction, and surface roughness have significant impact on the quality and quantity of bone osseointegration as well as the long-term survival of press-fit implants[4,5]. In patients with osteopenia and osteoporosis, both qualitative and quantitative properties of bone tissue deteriorate, leading to a weakening of bone metabolism that then leads to accelerated osteoclastogenesis and bone resorption[6,7]. The above situation is an unfavorable condition for the implantation of uncemented press-fit acetabular components[8].
In a previous experimental animal study utilizing a rat model, it was shown that osseointegration of current porous acetabular implant materials, as well as the possibility of successful implantation and osseointegration in osteoporotic bone,directly depends on the structural characteristics of the porous implant[9]. However,there is a lack of comparative data of the strength and stability of the bonе-metal osseointegration of current porous materials used in acetabular components in both normal and in osteoporotic bones.
The study aim was to carry out a comparative analysis of the strength of the formed bonе-metal osseointegration among four types of porous metal implants in anin vivoanimal model with both normal bone and after the simulation of osteoporosis. Our hypothesis was that there will be a difference in the strength between the formed bone metal osseointegration between normal and osteoporotic bone models.
Fifty female California rabbits 6 mo of age and weighing 4.5-5.0 kg) were kept in conditions of 24 °C, 12/12 h light/dark, and 60% humidity, withad libitumaccess to food and water, and a standard diet. All surgeries (ovariectomy and implantation of materials) were performed under general intramuscular anesthesia (xylazine hydrochloride 15 mg/kg and ketamine 50 mg/kg). Euthanasia was carried out by overdosing of ketamine (50 mg/kg) and subsequent air embolism. All experiments were performed according to the national guidelines and all appropriate measures were taken to minimize pain or discomfort to the animals. The study design was approved by the local Bioethics Committee.
Rabbits were randomly divided into healthy control non-ovariectomized (non-OVX)and ovariectomized (OVX) groups of 25 each. To simulate osteoporosis, ovariectomy was performed in the OVX group. After 3 mo, 10 rabbits (5 non-OVX and 5 OVX) were sacrificed to confirm of osteoporosis development. For the remaining rabbits, (n= 40)one of the four types of porous materials were implanted. All rabbits with implants were sacrificed 8 wk after implantation.
The four types of implants used in this study were of comparable 80% or greater porosity. Three were Ti6-Al4-V titanium alloys: TTM (AK Medical, Beijing, China),CONCELOC (Smith & Nephew, Memphis, TN, United States), ATLANT (TITANMED, Kyiv, Ukraine). The fourth was porous Zimmer Biomet's Trabecular Metal(TANTALUM) (Zimmer, Warsaw, United States). The elastic moduli are 3 GPa for TANTALUM[10], 12.9 for GPa[11], 4.3 GPa for CONCELOC[12], and 113 GPa for ATLANT.A 1.2 mm diameter hole was drilled on one side of the implants to allow mounting of the testing jig. The testing jig that was attached to the implant was used to test breaking strength during the study (Figure 1A). Prior to implantation, the biomaterials were sterilized by autoclaving at 132 °C for 20 min.
Ovariectomy (n= 25) was performed under general anesthesia by two dorsolateral 2.5 cm incisions of the skin and muscles following the method described by Wandermanet al[13].
Implantation of materials:Each type of porous material was implanted in 5 healthy and 5 ovariectomized rabbits (n= 40) under general anesthesia under sterile conditions. The surgical field in the proximal part of the left femur was treated with Betadine antiseptic solution, after which the skin was incised from the lateral approach along the anterior femoral region above the greater trochanter. The musculus tensor fasciae latae and musculus quadriceps femoris were bluntly dissected and sequentially fixed. The greater trochanteric area was perforated by a burr to create a bone defect to match the biomaterial samples (diameter of 5 mm, length of 6 mm). After that, the wound was sutured in layers and the skin was treated with Betadine antiseptic. As postoperative pharmacological therapy, benzylpenicillin, dihydrostreptomycin(combikel 40) and meloxicam were administered.
Radiographic evaluation was performed three times. Three months after ovariectomy to control osteoporosis development in 5 OVX and 5 non-OVX rabbits, immediately after implantation to evaluate the position of implants, and at 8 wk after implantation for all 20 OVX and 20 non-OVX rabbits (Figure 2). In all cases, a digital X-ray diagnostic system (OPERA T90cex; General Medical Merate S.p.A., Italy) was used.
Figure 1 Scheme of biomechanical testing and biomechanical testing. A: The geometric dimension of the implants; B: Rabbit femur with implant on the stand during testing.
Figure 2 Х-ray images of rabbits after implanted CONCELOC material (arrow) in the proximal femur. А: Non-ovariectomized (non-OVX) rabbit after surgery; B: Non-OVX rabbit at 8 wk after surgery; C: Ovariectomized (OVX) rabbit after surgery; D: OVX rabbit at 8 wk after surgery.
Radiographs of the femur was obtained in 10 rabbits (5 OVX and 5 non-OVX) before implantation of materials to verify the osteoporosis model (Figure 3)[14]. This method is used as an alternative to measurement of bone mineral density in diagnosis of osteoporosis[14]. Using “X-Rays” software (Kharkiv National University of Radioelectronics, Ukraine)[15,16], the cortical thickness index was automatically calculated based on the measurement of the thickness of the cortical layer of the femur under the lesser trochanter in 10 rabbits. This software allows performing a coordinate-brightness analysis of digital radiographs, and provides spatial sampling with 0.042 mm elements and brightness quantization with a grayscale of 256 intensities. The analysis was performed by two independent experts.
Figure 3 Evaluation of the cortical thickness index of the proximal femur of rabbit with "X-Rays" software (Kharkiv National University of Radioelectronics, Ukraine) 3 mo after ovariectomy.
The implanted materials were rigidly fixed to the testing jig and breakout force testing was performed to detach the implant from the bone tissue (Figure 1B). We applied a breakout force to the implant at a constant speed of 1 mm per minute, which was gradually increased until complete detachment of the implant from the bone. The maximum value of the breakout force (N) was recorded with a strain gauge (SBA-100L) and a CAS type CI-2001A registration device (South Korea) (Figure 4).
Data were reported as means ± SD. Unpairedt-tests were used to evaluate the effect of osteoporosis on the stability of the same type of implant. Unpairedt-tests were performed for verification of osteoporosis model. To analyze the effect of the type of material on the strength of osseointegration in the non-OVX and OVX groups, oneway analysis of variance (ANOVA) was carried out with the post-hoc Duncan test. The critical level of significance was accepted as 0.05. The analysis was performed with IBM SPSS Statistics 19.0 software. The statistical methods were reviewed by Olena Karpinska and Michael Karpinsky of the Department of Biomechanics, Sytenko Institute of Spine and Joint Pathology, National Academy of Medical Sciences of Ukraine.
In the OVX group (n= 5), the cortical thickness index of the proximal femur was 1.4 times lower (P= 0.001) than that in the non-OVX group (n= 5) (0.482 ± 0.033vs0.660 ±0.007, unpairedt-test).
Data were obtained on the maximum breakout force that led to detachment of the implant from the femoral bone in both normal and osteoporotic bone tissue. The strength of the implant attachment in the femoral bone tissue was significantly higher in non-OVX group (n= 20), compared with the OVX group (n= 20) for all materials(Figure 5, unpairedt-test). When evaluating each implanted material, the breakout force was higher in the non-OVX group by a factor of 1.1 for TANTALUM (194.7 ± 6.1 Nvs181.3 ± 2.8;P= 0.005); CONCELOC (190.8 ± 3.6 Nvs180.9 ± 6.6 N;P= 0.019); and TTM (186.3 ± 1.8 Nvs172.0 ± 11.0 N;P= 0.043), and by a factor of 1.3 (104.9 ± 7.0 Nvs78.9 ± 4.5 N;P= 0.001) for ATLANT, compared with the OVX group.
Figure 4 Device for recording breakout force with a strain gauge.
Figure 5 Results of breakout force testing of four types of porous materials in ovariectomized (OVX, n = 20) and healthy rabbits (non-OVX, n = 20) 8 wk after implantation. A: Unpaired t-test: Analysis of the effect of osteoporosis (OVX group) on the bone-implant strength and osseointegration for the same type of implant; B: ANOVA with post-hoc Duncan test evaluation of the effect of the implant material on bone-implant strength and osseointegration in ovariectomized and non-ovariectomized rabbits. aP < 0.05; bP < 0.01; cP < 0.001. ns: not significant; non-OVX: non-ovariectomized; OVX: ovariectomized.
TANTALUM implants had the highest breakout strength in osteoporotic bone tissue at a load of 181.3 ± 2.8 N and in normal bone tissue at a load of 194.7 ± 6.1 N (Figure 5).The lowest breakout strength was shown in ATLANT implants. Failure was observed in normal bone tissue at a load of 104.9 N ± 7.0 N and in osteoporotic bone at 78.9 ± 4.5 N. In the OVX group (osteoporotic bone), the breakout forces of TANTALUM, TTM,and CONCELOC did not differ significantly (P= 0.066, Figure 5, one-way ANOVA).On the contrary, The breakout force of ATLANT implants was lower by a factor of 2.3 compared with TANTALUM and CONCELOC and by a factor of 2.2 compared with TTM (P= 0.001). Results in the non-OVX group (normal bone) were similar to those in the OVX group with minor differences (Figure 5, one-way ANOVA). The breakout force for TANTALUM and CONCELOC implants did not differ significantly (P=0.239). ATLANT implants were significantly different from all other implants, with a reduction in fixation strength of approximately 1.9 times (P= 0.001).
In this biomechanical study, we examined the strength of osseointegration of three porous titanium and one porous tantalum materials. We studied the breakout strength of the implanted materials 8 wk after their implantation in the metaphysis of the greater trochanter of the femur in anin vivorabbit model. Three of the studied materials in this study (TANTALUM, CONCELOC, TTM) are used in the manufacture of acetabular components for total hip replacement and are currently used in clinical practice. The fourth studied sample (ATLANT) is a new material used in the manufacture of acetabular cups. A unique aspect of our study is the comparison of the breakout strength among the four studied materials in both normal and osteoporotic bone in a rabbit ovariectomy model.
The importance of bone quality for osseointegration of porous implants has been shown both in cadaver studies[17,18]and in an animal model[19]. Beckmannet al[18]reported the results of a biomechanical study (multi-axial testing machine) that examined the mobility of an acetabular titanium cup with a porous surface in 10 cadaveric pelvises. They found an inverse relationship between the bone mineral density (BMD) of the femoral neck and the mobility of the acetabular cup. Similar data were obtained when using an additional acetabular porous augment[18]. The differences in osseointegration and breakout strength between different commercial acetabular cup materials are especially important in patients with low BMD. It has been found that patients with low BMD have an increased risk of migration of uncemented hydroxyapatite-coated titanium alloy acetabular cups 3–12 mo after total hip arthroplasty (THA) compared with patients with normal BMD[8]. According to a clinical study of 283 patients evaluated 2 years after revision THA, it was found that porous tantalum acetabular cups were more stable than porous titanium cups in patients with low BMD[20]. However, the long-term survivorship of acetabular cups in patients with osteoporosis is poorly understood in comparison with patients with normal BMD[21].
According to our data, the stability of implants in the OVX group was lower for all materials studied compared with the non-OVX group. Similar results were obtained by Fujimotoet al[19]when evaluating titanium implants in an experimental model of glucocorticoid-induced osteoporosis in rabbits. Similar to our results of the non-OVX group, Duanet al[22]presented biomechanical testing (push-out test) of medical Ti-6Al-4V substrates with titanium and tantalum coated implants. Their results showed that at 9 wk after implantation, the titanium and tantalum implants had similar push-out strengths when evaluated in New Zealand white rabbit femurs.
Our findings of similar breakout forces in tantalum (TANTALUM) and titanium implants (TTM and CONCELOC) in the OVX group may have occurred because the evaluated titanium implants had similar porosity, highlighting the importance of high porosity percentage in these implants. It has been shown that high porosity improves osseointegration compared to nonporous implants[23,24]. Pore size is also an important factor affecting osseointegration of the implant[23,24]. These variables probably explain the lower values of breakout force exhibited by the ATLANT component material compared with the other implants in both OVX and non-OVX models. A recent study in rabbits that compared titanium implants manufactured by additive technology and with three different pore sizes (500 μm, 700 μm and 900 μm)[25]showed that the best interfacial strength was achieved when the pore size was 700 μm, when evaluated by a push-out test at weeks 4 and 12 after implantation. This emphasizes the importance of the material pore size for its osseointegrative qualities. This knowledge may help manufacturers design materials made with similar technology and from different alloy materials. Nevertheless, when comparing tantalum and titanium implants with the same 500 μM pore size and 70% porosity in a rabbit model, the authors did not find any differences in the push-out test indices at 2 wk, 4 wk, and 8 wk after implantation[26]. The same results were reported in a similar study by Suet al[27]when comparing tantalum and titanium implants with the same pore size.
A limitation of our study was the use of one type of test to evaluate implant stability. However, our study is one of the few studies comparing tantalum and titanium materials in a low bone-mass model. Thus, these results will help expand the current knowledge of the stability of the studied materials in cases of osteoporosis.
TANTALUM, TTM and CONCELOC had equal bone-implant osseointegration in both healthy and osteoporotic bones. ATLANT showed a significant decrease in osseointegration (P= 0.001) in both healthy and osteoporotic bone.
Highly porous metal acetabular components are widely used in patients with low bone mass, but the strength of osseointegration may differ.
There is a need to perform stud ies to compare the strength of osseintegration of new porous metal biomaterials used in total hip arthroplasty of patients with low bone mass.
The objective of this study was to compare the strength of the formed bonе-metal osseointegration among four types of porous metal biomaterials in an in vivo animal model with both normal bone and after simulation of osteoporosis
The experimental study was performed in a rabbit model of postmenopausal osteoporosis. Biomechanical evaluation of the femur was carried out by testing the implant breakout force 8 wk after implantation of four types of biomaterials: TTM,CONCELOC, Zimmer Biomet's Trabecular Metal (TANTALUM), and ATLANT. The force was gradually increased until complete detachment of the implant from the bone.
The breakout force needed for implant detachment was significantly higher in healthy controls, compared with the ovariectomized group for all implants. The breakout force for ATLANT in the ovariectomized group was lower than that observed with TANTALUM, CONCELOC’ and TTM.
TANTALUM, TTM and CONCELOC had equal bone-implant osseointegration in healthy and osteoporotic bones. ATLANT showed a significant decrease in osseointegration in healthy and osteoporotic bone.
Further studies on the use of other biomechanical methods will expand the knowledge of the strength of osseointegration of modern porous materials, which will help in choosing optimal materials for acetabular implants when performing total hip arthroplasty in patients with osteoporosis.
World Journal of Orthopedics2021年4期