亚洲免费av电影一区二区三区,日韩爱爱视频,51精品视频一区二区三区,91视频爱爱,日韩欧美在线播放视频,中文字幕少妇AV,亚洲电影中文字幕,久久久久亚洲av成人网址,久久综合视频网站,国产在线不卡免费播放

        ?

        Use of short stems in revision of standard femoral stem: A case report

        2020-12-17 09:30:30FrancescoRobertoEvolaGiuseppeEvolaGiuseppeSessa
        World Journal of Orthopedics 2020年11期
        關(guān)鍵詞:需肥氮磷鉀肥

        Francesco Roberto Evola, Giuseppe Evola, Giuseppe Sessa

        Francesco Roberto Evola, Giuseppe Sessa, University of Catania, Department of Surgery, Clinic Orthopaedic, Catania 95124, Italy

        Giuseppe Evola, General and Emergency Surgery Department, Surgery Clinic, Catania 95124, Italy

        Abstract

        Key Words: Short stem; Revision procedure; Cementless implant; Total hip replacement; Prosthesis design; Case report

        INTRODUCTION

        Standard uncemented femoral stems have proven to be clinically, functionally, and radiologically successful in total hip replacement, particularly in young and active patients[1,2]. Recently, the use of short stems (stems with length < 120 mm) has become more popular; short stems have been designed to obtain optimal load transfer to the proximal femur, to ease stem removal in revision procedures, to reduce the rate of periprosthetic fractures, to preserve proximal femoral medullary bone, and to make implantation less invasive[3,4]. While standard stems have diaphyseal engagement that could likely cause proximal stress shielding, short stems have metaphyseal fixation and allow proximal load transfer, thereby reducing bone resorption. Clinical studies on short stems have found an increase in bone mineral density in the first and seventh area of Gruen from the 3rdmo[5,6]. Implant longevity relies upon an initial “press-fit” between the implant and the surrounding bone, which is a prerequisite for osseointegration of the stem, in order to achieve axial and rotational stability[7]. Metaphyseal stems could be an alternative for primary total hip replacement in young patients because this group has a high probability of undergoing revision surgery[8-10]. Because of their reduced size, short stems could be applied to first implants for posttraumatic obliteration of the femoral canal or excessive thickness of the diaphyseal cortex, when it is difficult to apply a standard stem. Some authors have used the short stem with cement[11]; advantages of a short-cemented implant include preservation of diaphyseal femoral bone, more proximal load transfer, easier insertion, and easier stem and cement removal in case of revision procedure[11]. Furthermore, in revision procedures for elderly patients with serious comorbidity and osteoporosis, applying a short-cemented stem could reduce the peri- and post-operative secondary surgical risks to femoral osteotomy, which is necessary for the removal of parts of the implant or acrylic cement from the medullary canal. Generally short stems require biological anchorage to the femur, so it would be particularly useful in select revision procedures to apply short stem anchorage in acrylic cement in cases where there is a lack of or reduced quality of the cancellous bone to obtain a primary stability of implant. Cemented short stems permit solid and immediate stability and do not require additional time for biological fixation[11]. There are no cases in the literature of applying a short stem for prosthetic revision by acrylic cement anchorage.

        This clinical case describes the unusual application of a biological short stem with acrylic cement in prosthetic revision, and we propose extending its application to special revision procedures and in selected patients in an attempt to reduce surgical invasiveness.

        CASE PRESENTATION

        Chief complaints

        An 80-year-old Caucasian patient with left hip prosthesis, 1.75 cm tall, first degree obesity (body mass index 33.5), and male sex, reported an accidental trauma to the pelvis and left femur after falling on the street.

        History of present illness

        Post-trauma, the patient walked with steppage gait and reported feeling pain in the left thigh; the pain did not decrease despite the administration of drugs.

        History of past illness

        Before the trauma the patient was asymptomatic and did not report any hip pain.

        Personal and family history

        There was no family history of treatment with elective hip replacement for osteoarthritis.

        Physical examination

        The patient reported pain in response to pressure on the thigh and external and internal rotation movements of the hip; no thigh oedema was found at the clinic examination.

        Laboratory examinations

        No laboratory tests were performed on the patient.

        Imaging examinations

        The patient had his left femur X-rayed 15 d post-trauma. The prosthesis had not been X-rayed for several years prior.

        FINAL DIAGNOSIS

        The X-ray highlighted the stem breakage in the distal section without fracture of the femoral cortex (Figure 1). Moreover, the stem showed a thickening of the femoral cortex at the distal end of implant, and the proximal part was loose without osteointegration. The radiographic image demonstrated a chronic implant loosening with subsequent traumatic rupture due to a positioning varus of the stem.

        TREATMENT

        Despite being active and autonomous in daily life, the patient had various comorbidities (diabetes, anaemia, heart deficiency, and arrhythmia) presenting a high operation risk (ASA 4). In the same month, the patient underwent a prosthetic stem revision. Watson-Jones access was performed with the patient in a supine position. During the revision, the distal apex of the stem could not be removed as it was anchored between the femoral cortex due to the reduced size of the medullary canal.

        Because of the poor general health of the patient, the surgeon decided not to perform a Wagner femoral osteotomy to remove the distal section of the stem. Implantation of a long stem with distal anchorage would have led to greater blood loss and a higher risk of infection with the likelyexitusof the patient. The surgeon decided to implant a short Fitmore stem to avoid removing the stem section of the previous implant that was solidly anchored to the medullary canal.

        Normally applied in selected patients as a biological implant, the Fitmore stem was used because of its reduced size to enable the revision of a standard-length stem. Due to the poor quality of bone tissue and the difficulty in obtaining primary stability for the new implant, the surgeon used acrylic cement to anchor the prosthesis. During surgery, a metallic femoral head (+ 4 mm) was used to obtain implant stability. The acetabulum showed no signs of movement, whereas the polyethylene insert showed signs of wear so it needed replacing. After 7 d in intensive care, the patient was transferred to the Orthopaedic Department and discharged 15 d after the operation. Subsequently, the patient was admitted to the rehabilitation unit for about 30 d.

        Figure 1 The X-ray of stem breakage.

        OUTCOME AND FOLLOW-UP

        X-ray and clinical checks were carried out for the next 2 years without showing signs of breakage to the femoral stem nor loosening of implant from cement. No subsidence at the stem-cement interface was observed, demonstrating the excellent stability of the cemented implant. The patient resumed normal life 3 mo post-operation. During the final check, roughly 2 years after the operation, the patient reported feeling no thigh pain and did not indicate limited articulation, living daily life without the assistance of walking aids (Figure 2).

        DISCUSSION

        There are three categories of prosthetic implant revision: Patient causes (infections), implant causes (aseptic loosening, peri-prosthetic fractures, implant failure or breakage), and surgical errors (instability, pain)[12]. Implant breakage is less common than aseptic loosening or infections and is caused by the mechanical stress generated by cyclic loads in most cases. Most stem failures are due to stainless steel components and present years after the operation.

        Steel stems often deform and then fracture before breaking, whereas chrome-cobalt stems fatigue and fracture without deforming. The section that is most often involved is the middle third distal stem, which shows a loss of bone support close to the femur, exposing that section to a shearing force followed by metal fatigue failure. The risk factors most associated with prosthetic stem breakage are weight gain or increased physical activity, the varus position of the stem, increased offset, small cross-section stems, the use of steel stems, and loosening of implant[12].

        試驗設(shè)5個處理,處理一:無肥對照,不施用任何肥料;處理二:常規(guī)無氮,按照本地常規(guī)施肥習慣施用磷鉀肥,不施用氮肥;處理三:配方無氮,按照土壤供肥和作物需肥特點合理配方施用磷鉀肥,不施用氮肥;處理四:常規(guī)施肥,按照本地常規(guī)施肥習慣施用氮磷鉀肥;處理五:配方施肥,按照土壤供肥和作物需肥情況合理配方施用氮磷鉀肥。

        Cementless implants have shown excellent long-term survival with respect to cemented prosthesis[1,2]. An essential condition in cementless implants is an optimal press-fit with low micromotions in the femur in order to allow secondary fixation to the bone. Proximal load transfer and the absence of distal fixation are essential for better clinical results in total hip arthroplasty. To reproduce natural load transfer in the subtrochanteric area, short stem devices were developed. Short stems include a large variety of prostheses that differ in shape, length, anchorage, level of bone resection, and reconstruction of the biomechanics of the femur[3].

        Within the family of short stems, the Fitmore stem is made of a titanium forged alloy covered with a porous coating, which allows the bone ingrowth process to be increased[5]. The anchorage concept is based on apposition to the calcar by the medial curve and contact with the lateral cortex through the axial load[13]. The concept of this stem geometry is based on the redistribution of 70% of loading forces on the calcar of the femur[14]. Trapezoidal cross-section allows for increase in primary stability, which is enhanced by a slightly oversized titanium coating. The Fitmore stem has a special design; the system portfolio consists of three different shaped stem families with different medial calcar curve radii to allow calcar and medial metaphyseal bony contact to be maximized[3]. There is a correlation between the calcar curve radius and the off-set; the valgus stem with large medial calcar radii has less of an off-set, while the varus stem with smaller calcar radii has a greater off-set. Generally, larger off-set is observed in males than in females. An increase in the offset leads to improved muscle strength, a greater range of motion and joint contact forces, and higher wear rate[15,16]; disadvantages are the increase in medial bending load, loading of the distal portion of the stem, and an increased risk of trochanteric pain.

        Figure 2 Radiographs at 2 years of follow-up.

        In this clinical case, we think the standard stem had a distal diaphyseal anchor on the femur and a chronic loosening of the proximal portion; the trauma broke the stem that had no anchorage in the metaphysis and proximal shaft, only in the distal part. In the literature, the revision of this implant required removal of the prosthesis and replacement with a standard or long stem[17,18]. The stem was easily removed during the surgery, while the distal apex of the stem could not be removed, as it was anchored between the femoral cortex. Patient's serious general clinical condition and intraoperative blood loss required a reduction in operating times. The presence of the tip of the stem in the femoral canal did not allow neither the use of a standard stem nor a long stem. Removing the broken part of the stem by a femoral osteotomy would have increased the surgical risk to the patient. Therefore, the small size of the short stems, normally used in primary implants and not in revisions, prevented femoral osteotomy and therefore reduced the risk of bleeding and infection in a patient with serious comorbidity. Due to the poor quality of bone tissue, the level of bone resection and the difficulty in obtaining primary stability for the new uncemented implant, the surgeon used acrylic cement to anchor the prosthesis. The surgeon did not have a short-cemented stem available, only the uncemented stem Fitmore. Short stems are usually uncemented prosthetic devices. The use of acrylic cement became necessary because of the lack of nearby bone, thereby preventing sufficient stable anchorage.

        Advantages of a short-cemented implant are minimal bone invasiveness, a decrease risk of bone-cement implantation syndrome, and an easier future revision procedure[11]. The main disadvantage of using an uncemented short stem with cement is the detachment of the implant at the prosthesis-cement interface due to the porous coating of Fitmore stem, causing short-term implant failure. The anchoring of the stem did not occur in the three points, calcar, lateral, and medial cortex of the metaphysis, but in the cortical femoral evenly, through the acrylic cement. The various off-sets of the Fitmore stem enabled the articular biomechanics to be reconstructed and ensured implant stability[16].

        Using an uncemented stem with acrylic cement is not correct. The short-cemented stem is little used among orthopaedists as they prefer biological fixation and these implants are unavailable. A short-cemented stem is feasible but requires specific implants and a perfect bone cement obtainable with cementation techniques. A precise cementing technique has permitted a homogeneous 2 mm cement mantle all around the stem, a prerequisite for a greater survival of prosthesis. Therefore, as more elderly osteoporotic patients require joint arthroplasty, it is possible to predict a return of cemented implants.

        One limitation of this study was the short-term follow-up given that the patient was assessed for 2 years after the revision before dying, so it was not possible to observe any loosening of the stem cement or any change in long-term implant stability.

        CONCLUSION

        A suggestive field of application of short stem may be the development of a cemented short design with different tapering angles to match the smaller femur in specific populations and to reduce the complexity of cemented or uncemented stem revision. Furthermore, the availability of cemented short stems could help surgeons to treat particular prosthetic revisions in patients in poor general health, thereby limiting surgical invasiveness and the use of long stems.

        猜你喜歡
        需肥氮磷鉀肥
        我國在境外首個百萬噸級鉀肥項目竣工
        玻利維亞擬建新的氮磷鉀肥料工廠
        釋放鉀肥儲備正當時
        馬鈴薯的生長條件與在遼西北半干旱地區(qū)的需肥特點及施肥關(guān)鍵技術(shù)
        鉀肥迎來零關(guān)稅
        姍姍來遲的鉀肥大合同
        植物需要氮磷鉀
        淺談紅干椒的需肥規(guī)律及施肥技術(shù)
        不同氮磷水平下AM真菌對棉花的侵染率及氮磷含量的影響
        不同濃度指數(shù)施肥方法下馬來沉香與土沉香苗期需肥規(guī)律
        456亚洲老头视频| 久久不见久久见免费视频7| 91九色最新国产在线观看| 精品久久久久久国产潘金莲| 久久久久久久99精品国产片| 亚洲综合av永久无码精品一区二区| 国产美女高潮流白浆视频| 色哟哟av网站在线观看| 久久国产36精品色熟妇| 国产精品99精品无码视亚| 日本黑人乱偷人妻在线播放| 国产三级三级三级看三级日本| 国产精品不卡无毒在线观看| 99亚洲男女激情在线观看| 亚洲天堂丰满人妻av| 久久婷婷综合激情亚洲狠狠| 国产视频嗯啊啊啊| 亚洲91av| 国产精品久久一区二区三区| 狂野欧美性猛xxxx乱大交| 九九久久精品国产免费av| 日本激情一区二区三区| 精品国产乱码一区二区三区在线| 黄色成人网站免费无码av | 国产av一区二区三区在线| 精品18在线观看免费视频| 国产日产高清欧美一区| 亚洲午夜福利在线视频| 欧美奶涨边摸边做爰视频| 美女露出奶头扒开内裤的视频| 日韩乱码精品中文字幕不卡| 国产欧美日韩专区毛茸茸| 欧美日韩综合网在线观看| 夜夜高潮夜夜爽夜夜爱爱| 未满十八勿入av网免费| 欧美群妇大交群| gg55gg国产成人影院| 国产黄色一区二区三区,| 亚洲中文字幕在线第二页| 在线a人片免费观看国产| 色婷婷资源网|