亚洲免费av电影一区二区三区,日韩爱爱视频,51精品视频一区二区三区,91视频爱爱,日韩欧美在线播放视频,中文字幕少妇AV,亚洲电影中文字幕,久久久久亚洲av成人网址,久久综合视频网站,国产在线不卡免费播放

        ?

        植入式遙測(cè)技術(shù)偶測(cè)血壓方法探究*

        2014-08-13 12:42:44曹開(kāi)進(jìn)李自強(qiáng)賀英菊宋相容
        中國(guó)病理生理雜志 2014年11期
        關(guān)鍵詞:測(cè)血壓植入式時(shí)段

        曹開(kāi)進(jìn), 李自強(qiáng), 賀英菊, 張 智, 3△, 宋相容△

        (四川大學(xué) 1華西藥學(xué)院, 2華西醫(yī)院生物治療國(guó)家重點(diǎn)實(shí)驗(yàn)室,四川 成都 610041; 3四川理工學(xué)院化學(xué)與制藥工程學(xué)院,四川 自貢 643000)

        血壓是動(dòng)物藥效學(xué)試驗(yàn)研究中的常用檢測(cè)指標(biāo)之一。目前,動(dòng)物血壓檢測(cè)常用方法主要有偶測(cè)血壓法和24 h動(dòng)態(tài)血壓監(jiān)測(cè)法(即植入式遙測(cè)技術(shù))。傳統(tǒng)的血壓偶測(cè)方法如尾套法、頸動(dòng)脈插管法等,易引起動(dòng)物應(yīng)激反應(yīng),導(dǎo)致血壓、心率和體溫等生理生化參數(shù)的較大波動(dòng),致使試驗(yàn)數(shù)據(jù)離散度大,且重復(fù)性差[1-4]。而植入式遙測(cè)技術(shù)可減少動(dòng)物因束縛產(chǎn)生的應(yīng)激反應(yīng),能更準(zhǔn)確地測(cè)定動(dòng)物真實(shí)的血壓值,并可實(shí)時(shí)監(jiān)測(cè)血壓,受到廣大研究者的青睞[4-5]。

        用植入式遙測(cè)技術(shù)測(cè)定血壓時(shí),常需24 h連續(xù)采集血壓的實(shí)時(shí)數(shù)據(jù),再以24 h的血壓均值作為動(dòng)物的當(dāng)日血壓。因此,就需對(duì)植入子(植入式傳感器)進(jìn)行連續(xù)開(kāi)機(jī),會(huì)嚴(yán)重耗損植入子電池的電量。植入子價(jià)格較為昂貴,且其電池壽命短,不能達(dá)到長(zhǎng)期監(jiān)測(cè)血壓的目的[1]。鑒于此,本課題以自發(fā)性高血壓大鼠(spontaneously hypertensive rats, SHR)為模型動(dòng)物,對(duì)其24 h血壓連續(xù)變化規(guī)律進(jìn)行系統(tǒng)分析,旨在建立植入式遙測(cè)技術(shù)偶測(cè)血壓方法,以在保證獲取數(shù)據(jù)的準(zhǔn)確性和科學(xué)性基礎(chǔ)上,進(jìn)一步提高植入子的使用壽命和效率。

        材 料 和 方 法

        1 動(dòng)物

        8只20周齡雄性SHR,SPF級(jí),體重約300 g,購(gòu)自北京維通利華實(shí)驗(yàn)動(dòng)物技術(shù)有限公司。大鼠飼養(yǎng)在SPF級(jí)動(dòng)物房,喂以基礎(chǔ)飼料,自由飲水,溫度(20±3)℃,相對(duì)濕度50%~60%。光照周期為晝夜各12 h。

        2 主要試劑

        戊巴比妥鈉(成都市科龍化工試劑廠);克林霉素磷酸酯注射液(西安利君制藥有限責(zé)任公司);纖維貼(DSI);生物膠(DSI);替米沙坦(山東平原制藥廠)。

        3 主要方法

        3.1植入子手術(shù)和信號(hào)采集 本研究所采用的生理參數(shù)遙測(cè)系統(tǒng)為Data Sciences International(DSI)公司生產(chǎn),它由植入式傳感器(植入子TA11PA-C40)、數(shù)據(jù)轉(zhuǎn)換器、數(shù)據(jù)接收器、外界壓力監(jiān)控器、數(shù)據(jù)處理軟件(Dataquest A.R.T. 4.33),遙感測(cè)壓監(jiān)測(cè)系統(tǒng)等裝置組成。動(dòng)物體內(nèi)的傳感器以無(wú)線的方式將生理信號(hào)傳送給信號(hào)接收裝置。植入子TA11PA-C40可以同時(shí)監(jiān)測(cè)血壓、心率、活動(dòng)度等生理信號(hào)。植入子植入手術(shù)按照DSI公司操作說(shuō)明進(jìn)行,操作如下:按照5 mL/kg劑量注射 1%戊巴比妥鈉麻醉SHR,沿腹中線開(kāi)口以暴露腹腔內(nèi)容物,用棉簽將腸道撥到旁邊推至四周;用棉簽分離腹主動(dòng)脈,在左腎靜脈的交叉處下方和腹主動(dòng)脈尾端的分叉處前方,用彎鑷子繞過(guò)腹主動(dòng)脈引入4-0 的縫線,打一個(gè)松結(jié)后,止血鉗夾持末端;準(zhǔn)備植入子,取5 mL注射器針尖,將針尖端斜面一側(cè)彎折90°,拉緊縫合線末端的止血鉗,用針頭在髂動(dòng)脈分叉前方刺破血管后,立即將植入子壓力導(dǎo)管輕輕插入血管,拔出針頭,推進(jìn)導(dǎo)管至4 cm。吸取少量生物膠,然后輕觸穿刺點(diǎn)左右和導(dǎo)管下方各1 次,待生物膠凝固約15 s后松開(kāi)阻斷主動(dòng)脈血液的縫合線,取出用于阻隔內(nèi)臟的紗棉;將植入子放到腸道的上方,進(jìn)行腹壁肌肉縫合;術(shù)后1~7 d每天給動(dòng)物腿部肌注克林霉素磷酸酯注射液防止感染,并每天用碘酊對(duì)創(chuàng)部進(jìn)行消毒。手術(shù)恢復(fù)2周后開(kāi)始進(jìn)行血壓連續(xù)監(jiān)測(cè),先以每10 s采集1次的方式連續(xù)采集4 d 的SHR基礎(chǔ)血壓;然后以替米沙坦為藥物,按照3 mg/kg的藥效學(xué)劑量對(duì)SHR進(jìn)行連續(xù)9 d的治療,并對(duì)治療期間的血壓等生理信號(hào)以同樣的方式連續(xù)采集9 d。

        3.2SHR動(dòng)態(tài)血壓變化的數(shù)據(jù)處理 采用數(shù)據(jù)處理軟件Dataquest A.R.T. 4.33對(duì)上述連續(xù)4 d間隔10 s采集的血壓生理信號(hào)進(jìn)行處理,獲取相關(guān)的血壓值,繪制SHR基礎(chǔ)血壓動(dòng)態(tài)變化曲線,并研究SHR動(dòng)態(tài)血壓[包括收縮壓(systolic blood pressure, SBP)和舒張壓(diastolic blood pressure, DBP)]的變化規(guī)律。

        3.3不同時(shí)段血壓均值變化的分析 SHR每天的血壓信號(hào)進(jìn)行如下處理:分別以30 min、1 h 和3 h為間隔時(shí)段,應(yīng)用軟件計(jì)算該時(shí)段內(nèi)的血壓平均值,再進(jìn)一步計(jì)算8只SHR連續(xù)4 d血壓在不同時(shí)段內(nèi)的均值和標(biāo)準(zhǔn)差,并繪制24 h不同間隔時(shí)段的血壓均值散點(diǎn)圖。

        3.4不同時(shí)段血壓均值曲線與24 h血壓均值曲線的相似性分析 取前述用植入式遙測(cè)技術(shù)測(cè)過(guò)血壓的8只SHR,每天早上10時(shí)灌胃給予3 mg/kg替米沙坦,連續(xù)給藥9 d,同時(shí)繼續(xù)用植入式遙測(cè)技術(shù)連續(xù)采集血壓等生理信號(hào)。計(jì)算24 h的血壓均值,形成10個(gè)數(shù)據(jù)點(diǎn)(包括治療前1 d的基礎(chǔ)數(shù)據(jù)),繪制24 h血壓均值曲線;并分別計(jì)算每天3:00~3:30、20:00~21:00、2:00~5:00和20:00~23:00時(shí)間段的血壓均值,各形成10個(gè)數(shù)據(jù)點(diǎn),繪制相應(yīng)的血壓均值曲線。采用“相似因子比較法”對(duì)血壓均值曲線的相似性進(jìn)行分析,用公式1計(jì)算血壓均值曲線的相似因子(f2),用公式2計(jì)算每天血壓平均差異,再結(jié)合血壓平均差異與相應(yīng)相似因子f2臨界值的關(guān)系,整體評(píng)價(jià)上述各時(shí)段的血壓均值曲線與24 h血壓均值曲線的相似性。

        公式1:

        Rt和Tt分別表示2條曲線在第n天時(shí)的血壓均值。

        公式2:

        4 統(tǒng)計(jì)學(xué)處理

        用SPSS 16.0統(tǒng)計(jì)軟件分析,數(shù)據(jù)用均數(shù)±標(biāo)準(zhǔn)差(mean±SD)表示。

        結(jié) 果

        1 24 h SHR動(dòng)態(tài)血壓變化的特點(diǎn)分析

        如圖1所示,SHR血壓變化存在一定節(jié)律性,即每天的血壓存在相似變化趨勢(shì)(包括收縮壓和舒張壓),血壓波形呈現(xiàn)“V”字型變化,上午10時(shí)左右血壓達(dá)到最高后,呈現(xiàn)波動(dòng)下降,下午血壓較低,至次日凌晨血壓開(kāi)始上升。不同天同一時(shí)點(diǎn)的血壓變化較大,重復(fù)性差,不穩(wěn)定,甚至差異達(dá)到20 mmHg以上,提示用某一時(shí)點(diǎn)測(cè)得血壓代表24 h血壓均值不可行。

        Figure 1. The dynamic curve of basic blood pressure for consecutive 4 d of SHR.

        2 不同時(shí)段動(dòng)態(tài)血壓均值變化分析

        如圖2~4所示,間隔時(shí)段越短,SHR不同天同一時(shí)段血壓均值變化波動(dòng)越大,偏離24 h血壓均值線也越大。隨間隔時(shí)段的延長(zhǎng),血壓均值變化波動(dòng)顯著降低,穩(wěn)定性和重復(fù)性亦顯著提高。在3:00~3:30、20:00~21:00、2:00~5:00和20:00~23:00時(shí)段內(nèi)(圖2~4,箭頭標(biāo)示),其血壓均值與24 h血壓均值均比較相似,且變化較小,如連續(xù)4 d 20:00~23:00時(shí)間段血壓均值間的標(biāo)準(zhǔn)差僅為1.21 mmHg(圖4)。由此提示,上述4個(gè)時(shí)段內(nèi)獲取的血壓均值能較好代表24 h的血壓均值。

        3 不同段血壓均值曲線與24 h血壓均值曲線的相似性分析

        采用“相似因子比較法”分析,結(jié)果發(fā)現(xiàn)在3:00~3:30、20:00~21:00、2:00~5:00和20:00~23:00時(shí)段分別獲取的血壓均值曲線,與24 h收縮壓均值曲線之間的相似因子f2 分別達(dá)到50. 5、55. 8、72. 3和77. 8,血壓均值之間的最大差異分別為14. 2%、13. 5%、4. 7%和3. 1%; 而與24 h 舒張壓均值曲線之間的相似因子f2 分別達(dá)到50. 7、59. 9、70. 6 和78. 0,血壓均值之間的最大差異分別為22. 4%、17. 4%、9. 7%和4. 3%,見(jiàn)圖5。根據(jù)血壓均值最大差異與相似因子f2 結(jié)果,提示在20: 00 ~ 23: 00 時(shí)段獲取的血壓均值曲線與24 h 血壓均值曲線最為相似,可以更好地評(píng)估SHR 24 h 的血壓均值。

        Figure 2. The 24-h dynamic changes of the mean systolic and diastolic pressure at 30-min time interval. The scatter plot represents the mean blood pressure of different time periods at 30-min interval, and the arrow represents the time period of 3:00~3:30, at which the mean blood pressure was the most closest to the mean blood pressure of 24 h and had minimum SD value. The mean blood pressure lines of 4 d represent the mean blood pressure of consecutive 4 d. Mean±SD. n=8.

        Figure 3. The 24-h dynamic changes of the mean systolic and diastolic pressure at 1-h time interval. The scatter plot represents the mean blood pressure of different time periods at 1-h interval, and the arrow represents the time period 20:00~21:00, at which the mean blood pressure was the closest to the mean blood pressure of 24 h and had minimum SD value. The lines of mean blood pressure of 4 d represent the mean blood pressure of consecutive 4 d. Mean±SD. n=8.

        Figure 4. The 24-h dynamic change of the mean systolic and diastolic pressure at 3 h time interval. The scatter plot represents the mean blood pressure of different time periods at 3-h interval, and the arrows represent the time periods of 20:00~23:00 and 2:00~5:00,at which the mean blood pressure was the most closest to the mean blood pressure of 24 h and had minimum SD value. The mean blood pressure lines of 4 d represent the mean blood pressure of consecutive 4 d. Mean±SD. n=8.

        討 論

        尾套法和有創(chuàng)頸動(dòng)脈法是常用的傳統(tǒng)血壓測(cè)定方法。尾套法在測(cè)定血壓的時(shí)候需要對(duì)動(dòng)物進(jìn)行限制和加熱;同時(shí),該法測(cè)定的是外周動(dòng)脈壓,顯著高于植入式遙測(cè)技術(shù)測(cè)定的中心動(dòng)脈壓,因此尾套法測(cè)得的血壓無(wú)法準(zhǔn)確反映出正常的血壓值[2, 6-7]。而有創(chuàng)頸動(dòng)脈法的監(jiān)測(cè)時(shí)間很受限制,通常不宜超過(guò)4 h,且易造成傷害,很難實(shí)現(xiàn)對(duì)SHR的血壓等生理參數(shù)進(jìn)行長(zhǎng)期有效監(jiān)測(cè)[1]。與傳統(tǒng)血壓測(cè)定方法相比,植入式遙測(cè)技術(shù)能最大程度地減少對(duì)實(shí)驗(yàn)動(dòng)物的人工干預(yù)和刺激,在動(dòng)物自由活動(dòng)、清醒的情況下進(jìn)行長(zhǎng)時(shí)間持續(xù)記錄血壓等生理參數(shù),保證數(shù)據(jù)的客觀性和準(zhǔn)確性[7]。目前該技術(shù)采集血壓等生理信號(hào)的方式主要是連續(xù)開(kāi)機(jī)采集法,因此對(duì)植入子電池使用壽命是一個(gè)較大的考驗(yàn)[1,8-9]。本研究提出將植入式遙測(cè)技術(shù)應(yīng)用于偶測(cè)血壓方法,以克服傳統(tǒng)偶測(cè)血壓方法準(zhǔn)確性和重復(fù)性差以及植入子使用壽命有限等缺陷。然而,將植入式遙測(cè)技術(shù)應(yīng)用于偶測(cè)血壓方法時(shí),如何選擇監(jiān)測(cè)時(shí)段,選擇多長(zhǎng)時(shí)段,其獲取的血壓均值能否代表24 h血壓均值,這些問(wèn)題尚缺乏系統(tǒng)研究。

        Figure 5. Similarity analysis of the mean blood pressure curves of 3:00~3:30, 20:00~21:00, 2:00~5:00 and 20:00~23:00 time periods and the mean blood pressure curve of 24 h.Mean±SD. n=8.

        本研究首先對(duì)SHR 24 h基礎(chǔ)血壓原始信號(hào)的動(dòng)態(tài)變化進(jìn)行分析,結(jié)果表明雖然SHR血壓存在一定的晝夜變化規(guī)律和波動(dòng)特點(diǎn),但由于不同天同一時(shí)點(diǎn)的血壓值變化較大,很難直接找到一段變化或波動(dòng)較為平穩(wěn)的時(shí)段(圖1)。因此,我們放棄直接從血壓原始信號(hào)尋找合適監(jiān)測(cè)時(shí)段的方法,改為以30 min、1 h、3 h為間隔時(shí)段,應(yīng)用數(shù)據(jù)分析軟件計(jì)算不同時(shí)段的血壓均值,并通過(guò)觀察不同時(shí)段血壓均值的動(dòng)態(tài)變化特征,來(lái)尋找能代表24 h血壓均值的時(shí)段。結(jié)果表明,分別以30 min、1 h、3 h為間隔時(shí)段時(shí),均能找到一些與24 h血壓均值相近且標(biāo)準(zhǔn)差較小的時(shí)段,如3:00~3:30、20:00~21:00、2:00~5:00和20:00~23:00(圖2~4,箭頭標(biāo)示)。我們采用“相似因子比較法”對(duì)這些時(shí)段的血壓均值進(jìn)行評(píng)估,通過(guò)對(duì)連續(xù)給予替米沙坦治療9 d SHR在上述時(shí)段的血壓均值曲線與24 h血壓均值曲線的相似度進(jìn)行比較分析,確定了在20:00~23:00時(shí)段獲取的血壓均值能更好的代表24 h血壓均值(圖5)。

        本研究首次提出將植入式遙測(cè)技術(shù)應(yīng)用于偶測(cè)血壓方法,并證實(shí)在20:00~23:00時(shí)段進(jìn)行開(kāi)機(jī)監(jiān)測(cè)血壓,能獲得準(zhǔn)確和科學(xué)的血壓數(shù)據(jù),很好地評(píng)估SHR 24 h的血壓均值。該方法一方面是對(duì)目前植入式遙測(cè)技術(shù)測(cè)定血壓方法的有力補(bǔ)充和擴(kuò)展;另一方面,通過(guò)對(duì)SHR 24 h的血壓均值變化特點(diǎn)的分析,為傳統(tǒng)血壓偶測(cè)方法在血壓監(jiān)測(cè)時(shí)點(diǎn)或時(shí)間段的選擇提供了參考。

        [參 考 文 獻(xiàn)]

        [1] Van Vliet BN, Chafe LL, Antic V, et al. Direct and indirect methods used to study arterial blood pressure[J]. J Pharmacol Toxicol, 2000, 44(2):361-373.

        [2] Irvine RJ, White J, Chan R, et al. The influence of restraint on blood pressure in the rat[J]. J Pharmacol Toxicol, 1997, 38(3):157-162.

        [3] Kubota Y, Umegaki K, Kagota S, et al. Evaluation of blood pressure measured by tail-cuff methods (without heating) in spontaneously hypertensive rats [J]. Biol Pharm Bull, 2006, 29(8):1756-1758.

        [4] Pinna GD, Maestri R, Mortara A, et al. Long-term time-course of nocturnal breathing disorders in heart failure patients[J]. Eur Respir J, 2010, 35(2):361-367.

        [5] Massagram W, Hafner N, Chen MQ, et al. Digital heart-rate variability parameter monitoring and assessment ASIC[J]. IEEE Trans Biomed Circuits Syst, 2010, 4(1):19-26.

        [6] 李 虹, 肖傳實(shí), 王 蕾, 等. 不同周齡自發(fā)性高血壓大鼠動(dòng)態(tài)血壓變化及阻力血管形態(tài)學(xué)研究[J]. 中國(guó)病理生理雜志, 2011, 27(4):653-657.

        [7] Bazil MK, Krulan C, Webb RL. Telemetric monitoring of cardiovascular parameters in conscious spontaneously hypertensive rats[J]. J Cardiovasc Pharmcol, 1993, 22(6):897-905.

        [8] Anderson NH, Devlin AM, Graham D, et al. Telemetry for cardiovascular monitoring in a pharmacological study: new approaches to data analysis[J]. Hypertension, 1999, 33 (1 Pt 2):248-255.

        [9] Ning G, Bai Y, Yan W, et al. Investigation of beat-to-beat cardiovascular activity of rats by radio telemetry[J]. Clin Hemorheol Microcirc, 2006, 34(1-2):363-371.

        猜你喜歡
        測(cè)血壓植入式時(shí)段
        完全植入式輸液港與PICC應(yīng)用效果的系統(tǒng)評(píng)價(jià)再評(píng)價(jià)
        先排小便再測(cè)血壓
        愛(ài)焦慮的人別自測(cè)血壓
        體內(nèi)植入式磁耦合諧振無(wú)線電能傳輸系統(tǒng)研究
        電子制作(2019年7期)2019-04-25 13:17:52
        四個(gè)養(yǎng)生黃金時(shí)段,你抓住了嗎
        試論植入式廣告在春晚中的應(yīng)用
        新聞傳播(2018年5期)2018-05-30 07:02:55
        測(cè)血壓時(shí)別憋尿
        用于植入式器件的電源技術(shù)研究進(jìn)展
        傍晚是交通事故高發(fā)時(shí)段
        分時(shí)段預(yù)約在PICC門(mén)診維護(hù)中的應(yīng)用與探討
        国产白色视频在线观看| 在线观看av中文字幕不卡| 欧美日本免费一区二| 国产精品女人一区二区三区| 漂亮丰满人妻被中出中文字幕| 日韩av无码久久一区二区| 又色又污又爽又黄的网站| 中文字幕一区二区三区人妻精品 | 亚洲国产精品一区二区成人av| 国产熟妇另类久久久久| 1000部拍拍拍18勿入免费视频下载| 狠狠色丁香婷婷久久综合2021 | 国产亚洲精品aaaa片小说| 美女裸体无遮挡免费视频的网站| 一区二区三区岛国av毛片| 国产精品亚洲二区在线看| 色www视频永久免费| 精品视频入口| 91国内偷拍一区二区三区| 亚洲 小说区 图片区 都市| 99精品一区二区三区无码吞精| 欧美日本道免费二区三区| 国产av精品一区二区三区视频| 精品香蕉99久久久久网站| 8ⅹ8x擦拨擦拨成人免费视频| 久久精品国产热久久精品国产亚洲| 亚洲日本中文字幕乱码| 国产成a人亚洲精品无码樱花| 精品人妻系列无码一区二区三区| 无码专区亚洲avl| 中文字幕34一区二区| 国产高潮视频在线观看| 国产精品亚洲欧美天海翼| 加勒比久草免费在线观看 | 999国内精品永久免费观看| 国产一区二区精品在线观看 | 国产人妻人伦精品1国产盗摄| 久久久久国产亚洲AV麻豆| 色婷婷av一区二区三区丝袜美腿| 国产七十六+老熟妇| 国产一区二区三区在线观看精品|