摘 要:采用注入法進行了高度表對脈沖雷達的敏感度實驗,測出了高度表對脈沖雷達的敏感度。實驗表明,高度表受到脈沖雷達干擾時,高度表的讀數(shù)誤差增大,且隨著雷達干擾信號強度的增加,高度表讀數(shù)誤差也增大。為了研究脈沖雷達對高度表的干擾機理,介紹了高度表工作原理,分析了高度表的信號和數(shù)據(jù)處理過程。在此基礎上得出如下結論:干擾使平衡檢波器信號波形上出現(xiàn)了許多窄脈沖,這些窄脈沖使高度表誤差增大,最后給出了抗干擾對策。
關鍵詞:高度表;脈沖雷達;電磁兼容;敏感度;干擾
中圖分類號:TN953.2 文獻標識碼:A 文章編號:1004373X(2008)1704203
Study on EMC between Altimeter and Pulse Radar
HOU Minsheng,ZHU Ying
(Beijing Aeronautical Technology Research Center,Beijing,100076,China)
Abstract:The injection experimentation of altimeter sensitivity to pulse radar is made,and the sensitivity is tested.The experimentation shows that interference signal of pulse radar can change the reading of altimeter,and the altimeter′s error increases as the interference intensity does.In order to study the interference principle of pulse radar to altimeter,the work principle of altimeter is introduced,and the signal and data processing of altimeter are analyzed.Based on this,the paper come to the conclusion that many narrow pulses on the waveform generated by balance detector make the altimeter′s error increases.In the end,the anti-jamming methods are given.
Keywords:altimeter;pulse radar;EMC;sensitivity;interference
電子技術的飛速發(fā)展,特別是大規(guī)模和超大規(guī)模集成電路的廣泛應用,使各種電子設備的電磁敏感度越來越高[1]。另一方面,各種新型電子設備如雨后春筍般地出現(xiàn),它們發(fā)射的電磁波使有限的空間變得越來越擁擠,電磁環(huán)境越來越復雜、惡劣。這些都導致了電子設備之間的電磁兼容性問題的日趨嚴重,電子設備之間的干擾已到了不可忽視的地步[2]。例如,雷達與雷達之間、雷達與自衛(wèi)干擾機之間、機載電臺與敵我識別器之間都存在著不同程度的干擾,有的甚至根本就無法同時工作。本文以無線電高度表為研究對象,通過實驗室模擬實驗,測出了高度表對地面脈沖雷達的敏感度,研究了雷達干擾無線電高度表的機理。
1 無線電高度表的敏感度實驗
1.1 實驗方法及配置
接收機敏感度的測量方法有兩種:一種是電磁場輻射法;一種是注入法[3]。電磁場輻射法測量時,將干擾源產(chǎn)生的干擾信號由天線輻射出去,被試接收機天線置于其輻射場中;注入法測量時,不經(jīng)過天線,將干擾信號源與接收機輸入端直接相連。電磁場輻射法存在許多不確定因素,例如入射角、極化方向等。注入法沒有空間不確定因素,能夠較準確地測量被試設備的敏感度。本方案采用的是注入法,其實驗配置如圖1所示。